Inhaltszusammenfassung zur Seite Nr. 1
CHAPTER2
Cisco ASR 1000 Series Routers Components
The Cisco ASR 1000 Series Routers contain the following components:
• Cisco ASR 1000 Series Route Processor 1, page 2-1
Cisco ASR 1000 Series Embedded Services Processor, page 2-8
Cisco ASR 1000 Series SPA Interface Processor, page 2-10
Cisco ASR 1000 Series Router Power Supplies, page 2-14
Note Throughout this document, the term slot refers to a Cisco ASR 1000 Series Router chassis slot. The
Cisco ASR 1000 Series Route Processor 1, Cisco
Inhaltszusammenfassung zur Seite Nr. 2
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Route Processor 1 Downloading operational code for SIPs and Cisco ASR 1000 Series Embedded Services Processor over Ethernet out of band channel (EOBC), which is used for communication between the control processors on the Cisco ASR 1000 Series Routers CLI, alarm, network management, logging, and statistics aggregation Chassis management Ethernet out-of-band management Punt path processing for packets no
Inhaltszusammenfassung zur Seite Nr. 3
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Route Processor 1 Figure 2-1 shows the Cisco ASR 1000 Series RP1 faceplate for the Cisco ASR 1006 Router and ASR 1004 Router. Figure 2-1 Cisco ASR Series 1000 RP1 Faceplate LEDs and Connectors 1 CRIT HD PWR ACTV MAJ USB 2 STAT STBY MIN BF 3 ASR1000-RP1 01 DISK 5 4 1 Internal hard drive LED 4 USB 0, USB 1 connector 2 External USB Flash LED 5 ASR1000 RP1 LEDs 3 Internal USB bootflash LED Figure 2-2 shows the Cisco ASR
Inhaltszusammenfassung zur Seite Nr. 4
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Route Processor 1 Table 2-1 lists the Cisco ASR 1000 Series RP1 LEDs and behaviors. Table 2-1 Cisco ASR 1000 Series Route Processor 1 LEDs No. LED Label LED Color —State Behavior Description 1 PWR Power Solid green All power requirements are within specification Off Off, the router is in standby mode. 2 STAT System status Solid green Cisco IOS has successfully booted. Yellow ROMMON is running or when the Process M
Inhaltszusammenfassung zur Seite Nr. 5
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Route Processor 1 Table 2-1 Cisco ASR 1000 Series Route Processor 1 LEDs (continued) No. LED Label LED Color —State Behavior Description 12 LINK 10/100/1000 RJ-45 Solid Green Link with no activity. Interface LED Flashing Green Link with activity. Off No link. * The type of alarm triggered is associated with the driver itself. For example, environmental alarms are tied to our environmental code, SONET alarms are tie
Inhaltszusammenfassung zur Seite Nr. 6
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Route Processor 1 Code storage and download operational code to Cisco ASR 1000 Series Embedded Services Processor and Cisco ASR 1000 Series SPA Interface (SIP) Bulk storage is 40G hard disk drive (SSD optional) I/O support: 2 Mb upgradeable BootRom, 1GB Embedded USB memory (EUSB) 512 MB embedded USB, 1GB on RP1 for Cisco ASR 1006 Router and ASR 1004 Router, and 8GB on Cisco ASR 1002 Router Front panel s
Inhaltszusammenfassung zur Seite Nr. 7
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Route Processor 1 Table 2-3 lists the Cisco embedded ASR1000-RP1 LEDs and behaviors. Table 2-3 Cisco Embedded ASR1000-RP1 LEDs LED Label LED Color —State Behavior Description PWR Power Green All power requirements are within specification STAT System status Green Cisco IOS has successfully booted. Yellow BootROM has successfully loaded. Red System failure. MIN Minor Amber Minor alarm indicator. MAJ Major Red Major
Inhaltszusammenfassung zur Seite Nr. 8
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Embedded Services Processor Table 2-4 Cisco Embedded ASR1000-RP1 Connectors (continued) Label Type Description CON One RJ-45 for CON Console port used to connect to a terminal. AUX One RJ-45 for AUX Auxiliary port used for remote management purposes. Figure 2-3 shows a fully-loaded Cisco ASR 1002 Router. Figure 2-3 Cisco ASR 1002 Router Route Front View 1 2 4 3 1 FO slot 3 The eUSB panel door on the side of the Cis
Inhaltszusammenfassung zur Seite Nr. 9
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Embedded Services Processor The Cisco ASR 1000 Series Embedded Service Processors, Cisco ASR 1000-ESP5 and Cisco ASR1000-ESP10 provide two centralized forwarding-engine options for the Cisco ASR 1000 Series Aggregation Services Routers. The Cisco ASR 1000 Series ESPs: Are responsible for the data-plane processing tasks and all network traffic flows through them. Perform all baseline packet routing operations,
Inhaltszusammenfassung zur Seite Nr. 10
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series SPA Interface Processor Figure 2-4 shows the Cisco ASR 1000 Series Embedded Services Processor (ESP10) LEDS on the front panel. Figure 2-4 Cisco ASR1000-ESP10 Faceplate LEDs 1 2 PWR ACTV STAT STBY ASR1000-ESP10 3 4 1 Power LED 3 Status LED 2 Active LED 4 Standby LED Table 2-5 lists the Cisco ASR1000-ESP5 or ASR1000-ESP10 LEDs and behaviors. Table 2-5 Cisco ASR1000-ESP5 or ESP-10 Processor LEDs for the Cisco ASR 1002
Inhaltszusammenfassung zur Seite Nr. 11
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series SPA Interface Processor Contains one or more subslots which house one or more shared port adapters. Supports online insertion and removal (OIR) with SPAs inserted in the subslots. SPAs also support OIR and can be inserted or removed independently from the SIP. This section describes the Cisco ASR 1000 Series SPA Interface (SIP) components and subslot identification. Figure 2-5 shows the Cisco ASR 1000 Series SP
Inhaltszusammenfassung zur Seite Nr. 12
Chapter 2 Cisco ASR 1000 Series Routers Components Shared Port Adapters Table 2-6 describes the Cisco ASR 1000 Series SIP10 LEDs on the front panel. Table 2-6 Cisco ASR1000-SIP10 LEDs No. LED Label LED Color—State Behavior Description 1 PWR Power status indicates the Off Cisco ASR 1000 Series SIP is powered status of the power supply off Green Cisco ASR 1000 Series SIP is powered on 2 STATUS Indicates the current state of Red The Cisco ASR 1000 Series SPA the Cisco ASR 1000 Series Inte
Inhaltszusammenfassung zur Seite Nr. 13
CARRIER Chapter 2 Cisco ASR 1000 Series Routers Components Shared Port Adapters In the Cisco ASR 1004 Router, the Cisco ASR1000 Series SIP supports: Four half height (¼ rate or full rate or combination) Two full height (¼ rate or full rate or combination) SPAs with up to 32 ports per SPA The slot numbering for the SPAs in the Cisco ASR 1004 Router is the same as in the Cisco ASR 1006 Router. In the Cisco ASR 1002 Router, the Cisco embedded ASR1000-SIP10 supports: Three removable h
Inhaltszusammenfassung zur Seite Nr. 14
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Router Power Supplies Cisco ASR 1000 Series Router Power Supplies All Cisco ASR 1000 Series Router configurations support AC and DC power supply options. The modular chassis configurations support the installation of two power supplies for redundancy. When an external power supply fails or is removed, the other power supply provides power requirements for the chassis. You are required to always have two power supp
Inhaltszusammenfassung zur Seite Nr. 15
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Router Power Supplies DC Power System Input Requirements for Cisco ASR 1000 Series Routers The DC power supply for the Cisco ASR 1006, ASR 1004, and ASR 1002 routers operate at specifications. shows the common input ranges and circuit breaker requirements. Table 2-7 Cisco ASR 1000 Series Router DC Power Supply System Input Requirements Cisco ASR 1000 Series Router DC Power Supply System Input Rating (Amps) Circuit
Inhaltszusammenfassung zur Seite Nr. 16
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Router Power Supplies Table 2-9 AC and DC Power Supply System Rating Specifications for the Cisco ASR 1000 Series Routers Description Specification Power supply declared ratings AC = 100-240 VAC DC = –48/ –60 VDC Nominal line frequency rating 50/60 Hz Power Supplies for Cisco ASR 1006 Router The Cisco ASR 1006 Router can support up to 1200W output (AC and DC input). The 1200W power supply module consists of either a
Inhaltszusammenfassung zur Seite Nr. 17
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Router Power Supplies Figure 2-9 shows the AC power supplies at the rear of the Cisco ASR 1006 Router.The Cisco ASR 1006 Router supports up to two power supplies. The power supply LEDs and connectors on the rear of the chassis are described in Table 2-10. Figure 2-9 Cisco ASR 1006 Router AC Power Supply 6 7 8 OUTPUT INPUT INPUT FAIL OK OK ALARMS 60V 1A MAX 100-240V~ 16-7A 50-60HZ 5 This unit might have more than o
Inhaltszusammenfassung zur Seite Nr. 18
OUTPUT INPUT FAN FAIL OK OK ALARMS 60V 1A MAX. Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Router Power Supplies Figure 2-10 Cisco ASR 1006 Router AC Power Supply LEDs and DB-25 Alarm Connector 1 4 2 3 1 AC power supply LEDs 3 DB-25 alarm connector 2 AC power supply fan 4 AC power supply fan Table 2-10 describes the AC power supply LEDs on the Cisco ASR 1006 Router. Table 2-10 Cisco ASR 1006 Router AC Power Supply LEDs and Connector LED Label LED Color Descrip
Inhaltszusammenfassung zur Seite Nr. 19
Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Router Power Supplies LED Label LED Color Description FAN OK Bi-color LED indicates Green LED illuminates green when all fans are operational. fan status Red The LED illuminates red when a fan failure is detected. OUTPUT FAIL Power supply activity Red LED is red and turned off to signal that the AC output voltages are within the normal operating range; output voltage between the minimum and maximum limits will no
Inhaltszusammenfassung zur Seite Nr. 20
OFF Chapter 2 Cisco ASR 1000 Series Routers Components Cisco ASR 1000 Series Router Power Supplies Figure 2-11 Cisco ASR 1006 Router DC Power Supply 9 10 OUTPUT INPUT INPUT FAIL OK OK 55 ALARMS 60V -48/-60V 40A 1A MAX 8 7 This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 6 5 4 3 2 1 1 Fans 6 DC Power supply earth ground lugs 2 DB-25 alarm connector 7 DC Power supply captive screws 3 Tie-wrap tabs 8 DC Power supply