CONTENTS
Safety Precautions ....................................................................2
EF-G10CG
Unit Dimensions ........................................................................4
Names of Parts .........................................................................5
Installation ...................................................................
Inhaltszusammenfassung zur Seite Nr. 2
PRECAUTIONS FOR SAFE AND PROPER USE Regarding Symbol Indications Numerous symbols are employed as indication in the precautions for safety, precautions for handling, and in the indication to the products. These are designed to prevent in advance any possible infliction of injury on you and other individuals and the damage of properties through the proper use of the product. The symbols and meanings are shown below. Grasp the contents of the symbols completely before reading this manual. This rep
Inhaltszusammenfassung zur Seite Nr. 3
WARNING CAUTION To assure safety, special techniques are Do not install in locations subject to low or high required for installation. The customer should temperatures, near a kitchen table or never perform this work. Consult your dealer humidifier, or where there is oil smoke or water concerning installation. vapor. This can result in projector malfunction, deterioration of image quality, fire or electrical shock. Provide sufficient reinforcement when the Do not install the projector in a box o
Inhaltszusammenfassung zur Seite Nr. 4
UNIT DIMENSIONS All dimensions below are given in mm. 3-Ø11Elongated holes Ø11 200 240 454 402 436 396 72 223 5˚
5˚
15˚
15˚
These specifications are subject to change without notice. 4 English 318.5 114.5 120 377.5 150
Inhaltszusammenfassung zur Seite Nr. 5
Inhaltszusammenfassung zur Seite Nr. 6
INSTALLATION Special techniques are necessary for safe installation. The customer should never perform the installation work. Consult your dealer concerning installation. Projection Distance and Screen Size l This projector uses a 1.5X zoom lens; therefore, the maximum projected image size is 1.5 times larger than the minimum projected image size. l Focus is possible at projection distances of from 2.5m to 20m. Use the distances shown below for reference. Screen size (type) Distance from the fro
Inhaltszusammenfassung zur Seite Nr. 7
M5 ~8 { g X v O b V [ V ‰ b V [ ” h ~ M5 ~8 { g M5 ~8 { g X v O b V [ X v O b V [ V V M5 ~8 { g M5 ~8 { g ‰ b V [ X v O b V [ X v O b V [ ‰ b V [ ” h ~ ” h ~ V V ‰ b V [ ” h ~ ‰ b V [ M5 ~8 { g M5 ~8 { g X v O b V [ X v O b V [ ” h ~ V V ‰ b V [ ‰ b V
Inhaltszusammenfassung zur Seite Nr. 8
Inhaltszusammenfassung zur Seite Nr. 9
Inhaltszusammenfassung zur Seite Nr. 10
M5 ~8 { g X v O b V [ HOW TO PREVENT DROPPING V ‰ b V [ ” h ~ 1 Remove the U-fitting mounting screws. U-fitting 2 Attach a drop prevention chain or wire to the U-fitting and fasten firmly with a screw. Procure a drop prevention chain or If a chain is attached wire of sufficient strength. M5 5 8 bolt Spring washer 3 Mount the drop prevention fixture on the ceiling mount. To ceiling Flat washer Prepare the following accessories Drop prevention fixture M5 5 8
Inhaltszusammenfassung zur Seite Nr. 11
Inhaltszusammenfassung zur Seite Nr. 12
Inhaltszusammenfassung zur Seite Nr. 13
PROJECTION ANGLE ADJUSTMENTS Pre-adjustment Operations · Look at the projector instruction manual and turn on the power. · Use the zoom lens to match the projected image size to the size of the screen. Perform the above operations before starting the projection angle adjustments. Horizontal angle adjustment (top view) 1 Use the accessory hex wrench to loosen 6 bolts. 7˚
2 Move the projector left and right to center the projected image horizontally on the screen. 3 When the angle has been correc
Inhaltszusammenfassung zur Seite Nr. 14
REPLACING THE LAMP AND FILTER Observe the following cautions when replacing the light source lamp or filter. Failure to do so can result in personal injury or projector damage. · Turn off the POWER button of the remote control or OPERATE button of the projector and disconnect the power cord from the power outlet. · Take precautions to keep the DLG-G10U/E main unit and lens away from furniture, CAUTION lamps, etc. · Prepare a stable place to stand where you can work comfortably. When the installa
Inhaltszusammenfassung zur Seite Nr. 15
SPECIFICATIONS Part name : Ceiling mount Model : EF-G10CG Application : Ceiling mounting the DLA-G10U/E projector Applicable projector : DLA-G10U/E only Vertical tilt range : +/-15 degrees Horizontal tilt range : +/-5 degrees Horizontal pan range : +/-7 degrees Fixture Mass : 6.2kN Fixture size : 454mm (W) 5 359mm (D) 5 176mm (H) Mass with projector mounted : 20.5kN External dimensions with projector mounted : 454mm (W) 5 402mm (D) 5 377.5mm (H) Accessories : M8 5 15 screw (1), flat washer (1) S