Inhaltszusammenfassung zur Seite Nr. 1
U P S
Uninterruptible Power System
Line Interactive Network UPS
800VA/1000VA
1200VA/1500VA/2200VA
USER‘S MANUAL
Printed in USA
ABC
Inhaltszusammenfassung zur Seite Nr. 2
Important safety instructions Thank you for selecting this uninterruptible power system (UPS). It provides you with better protection for connected equipment. Please read this manual! This manual provides safety, installation and operating instructions that will help you derive the fullest performance and service life that the UPS has to offer. Please save this manual! It includes important instructions for the safe use of this UPS and for obtaining factory service should the proper operation of
Inhaltszusammenfassung zur Seite Nr. 3
Table of contents Introduction … … … … … … … … … … … … … 1 1 2 Safety … … … … … … … … … … … … … … … ..2 Presentation … … … … … … … … … … … … 3 3 Front Panel … … … … … … … … … … … … ..3 4 Rear Panel … … … … … … … … … … … … … 4 5 6 Installation … … … … … … … … … … … … … 5 Operation … … … … … … … … … … … … … .7 7 Alarms … … … … … … … … … … … … … … ..8 8 Software Options … … … … … … … … … … 9 9 10 Computer Interface Port… ……… ……10 Battery replacement… … …… … … …….11 11 Troubleshooting… … … … … … … …
Inhaltszusammenfassung zur Seite Nr. 4
1. INTRODUCTION The product is line interactive UPS with the newest technology and powerful function. The LINE INTERACTIVE UPS is with AVR function allows input voltage range from 75% to 125%, including on line voltage boost-up & buck down. An ideal protection equipment for critical connected loads. It is based on microprocessor controls, with utility power connected, the charging is ongoing, no need to switch ON the UPS and at back-up mode, UPS can be automatically turned OFF if none of the con
Inhaltszusammenfassung zur Seite Nr. 5
2. Safety CAUTION ! • To reduce the risk of electric shock, disconnect the UPS from the mains supply before installing a computer interface signal cable. Reconnect the power cord only after signaling interconnections have been made. • The internal energy source(the battery) cannot be de-energized by the user. The output may be energized when the unit is not connected to a mains supply. • The right way to de-energize the UPS properly in an emergency is to move the I/O switch to the OFF position a
Inhaltszusammenfassung zur Seite Nr. 6
3. Presentation FRONT PANEL 3.1 "REPLACE BATTERY" indicator (RED LED) The LED illuminates when the UPS's battery is no longer useful and must be replaced. 3.2 "BUCK AVR (VOLTAGE REDUCTION)" indicator (YELLOW LED) The LED illuminates when the UPS is correcting a high utility voltage condition. The loads receive normal power. 3.3 "BACK UP" indicator (YELLOW LED) The LED illuminates when the UPS is supplying battery power to the loads. 3.4 "BOOST AVR (VOLTAGE BOOST)" indicator (YELLOW LED) The LED
Inhaltszusammenfassung zur Seite Nr. 7
REAR PANEL 3.10 MAIN SWITCH 3.11 REMOTE PORT (COMPUTER INTERFACE) Provide both RS-232 and relay signal to support NOVELL, UNIX, DOS, WINDOWS and other operating systems. 3.12 TEL./MODEM SURGE PROTECTION Surge protection for telephone and modem line to have the complete safety connection for INTERNET service. 3.13 SITE WIRING FAULT INDICATORS (RED LED) It comes on when the UPS is connected to an improperly wired AC power outlet. Note: This device is available on 110 Vac model only. 3.14 SURGE PRO
Inhaltszusammenfassung zur Seite Nr. 8
4. Installation 4.0 Inspection Inspect the UPS upon receipt. The packaging is recyclable; save it for reuse or dispose of it properly. 4.1 Placement Install the UPS in a protected area with adequate air flow and free of excessive dust. Do not operate the UPS where the temperature and humidity is outside the specified limits. 4.2 Connect Computer Interface (optional) UPSMON series software (or other power management software) and an interface kits can be used with this UPS. Use only kits supplied
Inhaltszusammenfassung zur Seite Nr. 9
Note: This connection is optional. It is not necessary to use this UPS. Caution: The telephone line current limiting feature could be rendered inoperable if improperly installed. Make sure that the telephone line from the wall is plugged into the connector marked “IN”, and the device to be protected (telephone, modem, etc.) is plugged into the connector marked “OUT”. Caution: This surge protection device is for indoor use only and never install telephone wiring during a lightning storm. 4.5 Conn
Inhaltszusammenfassung zur Seite Nr. 10
5. Operation 5.1 Switch on With the UPS plugged in, turn on MAIN SWITCH (on rear panel) and press ON/OFF/TEST/SILENCE button (on front panel) less than 2 seconds to switch the UPS on. The UPS will perform self-testing each time when it is switched on. Note: When switched off the UPS maintains the battery charge and will respond to commands received through the computer interface port. 5.2 Switch off By pressing and holding ON/OFF/TEST/SILENCE button until the "LINE NORMAL" or "BACK UP" LED off.
Inhaltszusammenfassung zur Seite Nr. 11
6. Alarm 6.1 "BACK UP" (slow alarm) When in BACK UP mode, the YELLOW LED illuminates and the UPS sounds an audible alarm. The alarm stops when the UPS returns to LINE NORMAL operation. Press the ON/OFF/TEST/SILENCE button during on-battery alarms to stop the beeping. 6.2 "LOW BATTERY" (rapid alarm) In BACK UP mode, when the battery energy runs low, the UPS beeps rapidly until the UPS shuts down from battery exhaustion or returns to LINE NORMAL operation. 6.3 "OVERLOAD" (continuous alarm) When t
Inhaltszusammenfassung zur Seite Nr. 12
7. Software options 7.1 Power Monitoring Software The UPSMON series software (or other power monitoring software) is applied standard RS-232 interface to perform monitoring functions, and then provides an orderly shutdown of a computer in the event of power failure. Moreover, UPSMON displays all the diagnostic symptoms on monitor, such as Voltage, Frequency, Battery level and so on.. The software is available for DOS, Windows 3.1x, Windows 95, Windows NT V3.5 or later, Novell Netware and others
Inhaltszusammenfassung zur Seite Nr. 13
8. Computer Interface Port The computer interface port has the following characteristics: D-SUB 9 Pin Female Connector for white cable 5 Low Battery Contacts 2 Mains Failure Normally 4 Open Common 7 UPS Shut Down or 6 RS232 RD Pin 3 Signal High Min. 1 Second RS232 TX Pin 2 1 RS232 RTS Pin 7 8 RS232 DTR Pin 4 9 No Connection 3 Pin Number D-SUB 9 Pin Female Connector for purpure cable 5 Low Battery Contacts 2 Mains Failure Normally 4 Open Common 7 UPS Shut Down or 6 RS232 RD Pin 3 Signal High Min.
Inhaltszusammenfassung zur Seite Nr. 14
9. Battery Replacement Your battery should run any where from 3-5 years before eve needing to be replaced. Please follow the instructions below for easy battery replacement. Note: When replace battery, disconnect the utility power then open the case and take notice of the battery's polarity while install the new battery to avoid short. 1) Unplug unit from AC power source and disconnect all connected equipment. 2) Disconnect AC power cord from unit.. 3) Turn unit upside down and using a phillips
Inhaltszusammenfassung zur Seite Nr. 15
10. Troubleshooting PROBLEM POSSIBLE ACTION TO TAKE CAUSE UPS not on On/off/test/silence Press the on/off/test/silence LED not light button not pushed or button more than 1 second push too short Battery voltage less Recharge the ups at least 4 than 10V hours PCB failure Replace the PCB, call for service Load less than 20W at Normal condition battery mode UPS always at Power cord lose Replug the power cord battery mode AC FUSE burn out Replace the AC fuse Line voltage too high, Normal condition t
Inhaltszusammenfassung zur Seite Nr. 16
12. Specifications MODEL KIN KIN KIN KIN KIN 800AP 1000AP 1200AP 1500AP 2200AP INPUT Capacity 800VA 1000VA 1200VA 1500VA 2200VA Voltage +/-25% at line input Frequency 50 or 60Hz +/-10% (auto sensing) OUTPUT Voltage Simulated sine wave at 100V/110/115V/120V/220V/230V/240V (on battery) +/-5% Frequency 50 or 60Hz +/-0.5% (on battery) Voltage AVR automatically increase output voltage 15% above input Regulation voltage if -9% to-25% of nominal. AVR decrease output voltage AVR 13% below input voltage
Inhaltszusammenfassung zur Seite Nr. 17
Inhaltszusammenfassung zur Seite Nr. 18
Inhaltszusammenfassung zur Seite Nr. 19