Inhaltszusammenfassung zur Seite Nr. 1
Smart choice for power
C40R/50 Remote
C40R/100 Remote
DVM/C40 Faceplate
Installation Guide
C-Series Meter
Display
www.xantrex.com
Inhaltszusammenfassung zur Seite Nr. 2
Inhaltszusammenfassung zur Seite Nr. 3
C-Series Meter Display Installation Guide
Inhaltszusammenfassung zur Seite Nr. 4
About Xantrex Xantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units to one MW utility-scale systems for wind, solar, batteries, fuel cells, microturbines, and backup power applications in both grid-connected and stand-alone systems. Xantrex products include inverters, battery chargers, programmable power supplies, and variable speed drives that convert, supply, control, clean, and distribute electrical power. T
Inhaltszusammenfassung zur Seite Nr. 5
Contents 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. Important Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Additional Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3. Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 The Liquid Crysta
Inhaltszusammenfassung zur Seite Nr. 6
iv
Inhaltszusammenfassung zur Seite Nr. 7
1 Introduction Thank you for purchasing the Xantrex C-Series Meter Display. The C-Series Meter Display is an optional accessory for the C-Series Multifunction DC controllers C35, C40 and C60. It provides a digital display of the voltage, current, and amp-hour status for the C-Series Multifunction DC Controller. The C-Series Meter Display comes in two versions: the faceplate (DVM/C40), which replaces the front cover. the remote (C40R/50 and C40R/100), which can be installed remotely up t
Inhaltszusammenfassung zur Seite Nr. 8
Read this guide before connecting or using the C-Series Meter Display, and save it for future reference. The main topics in the guide are as follows: Important Safety Information on page 2 Features on page 4 Installation on page 7 Operation on page 17 Troubleshooting on page 18 Warranty and Return on page 19 2 Important Safety Information Misusing or incorrectly connecting the C-Series Meter Display may damage the equipment or create hazardous conditions for users. R
Inhaltszusammenfassung zur Seite Nr. 9
Warnings and Cautions WARNING: Explosion Hazard Do not use the C-Series Meter Display in the presence of flammable fumes or gases. Do not use the C-Series Meter Display in an enclosure containing automotive-type, lead-acid batteries. These batteries, unlike sealed batteries, vent explosive hydrogen gas, which can be ignited by sparks from electrical connections. WARNING: Shock Hazard Ensure all power sources are disconnected before proceeding. Failure to follow these safety guidelines may ca
Inhaltszusammenfassung zur Seite Nr. 10
3 Features The C-Series Meters have three features: a Liquid Crystal Display (LCD) to show current, voltage, amperage, resettable amp hours and total amp hours, an Amp-hour Reset Button, which is also used to illuminate or dim the display, and a Light Emitting Diode (LED) to indicate system status. LCD Display Amp-hour Reset/ Backlight Button Status LED The Remote The Faceplate Figure 2 Faceplate and Remote Features The remote is supplied with either a 50-foot (15 m) or a 100-foot (30.5
Inhaltszusammenfassung zur Seite Nr. 11
The Liquid Crystal Display (LCD) The LCD on the faceplate or remote provides the following information. Information Type Display Value/Range Current from PV Array or DC Load 0 to 85 amps DC (in whole numbers only) Battery Voltage 4 to 100 volts DC (in 0.2 volt increments) Watts 0 to 3,600 watts (volts x amps) Amp hours 0 to 65,536 Ah; can be reset to 0 Total amp hours 0 to 65,536 Ah; resets to zero when power is disconnected Status LED green, red, or orange Watts Volts Amps Amps displayed in w
Inhaltszusammenfassung zur Seite Nr. 12
Amp-Hour Reset and Backlight Button The amp-hour meter on the faceplate or remote can be reset by two different methods. Automatic resetting occurs when the C-Series Multifunction DC Controller is first connected and activated and each time its disconnected from the battery or the meter cable. To manually reset the amp-hour meter, press and hold the push-button on the front of the meter until the display resets. This button also activates or deactivates the backlight for the LCD when pres
Inhaltszusammenfassung zur Seite Nr. 13
Important: The green and red color of the LED only indicates the particular operating mode and the battery voltage level. It does not indicate whether the charging source is functioning properly. 4 Installation The following sections describe how to install the C-Series Meter Display. They include detailed instructions for the following steps. 1. Jumper Installation (Step 1): Set the voltage setting on the faceplate or remote to match the system voltage by installing the jumper over the app
Inhaltszusammenfassung zur Seite Nr. 14
Jumper Installation (Step 1) Four sets of jumpers are located on the right side of the circuit board on the back of the faceplate. Three jumpers set system voltage to 12 volts, 24 volts, or 48 volts. The fourth jumper dims the backlight on the display to conserve power and improve accuracy when longer cable runs are used. See Figure 5 for jumper locations. To enable a selection, carefully slide the jumper over the top of both pins. This is called installing the jumper. To disable a selectio
Inhaltszusammenfassung zur Seite Nr. 15
Faceplate Circuit Board Remote Circuit Board (backside) (backside) Potentiometer for Voltage LCD Contrast Jumpers Adjustment must match system voltage Remove this jumper for long cable runs, dimming the display, or conserving power. Figure 5 Jumper Locations on the FacePlate and Remote 975-0123-01-01 Rev A 9
Inhaltszusammenfassung zur Seite Nr. 16
Cable Installation (Step 2) Connect the display to the controller using the serial communications cable provided. The cable is a six-conductor telephone cable with modular-type connectors (RJ-15). Although any telephone-type cable will work, the cables provided with the displays use stranded and tin-plated wire for better performance and longer life. The following instructions are illustrated in Figure 6. To connect the Faceplate to the C-Series controller: 1. Remove the front cover of the
Inhaltszusammenfassung zur Seite Nr. 17
Remove these 4 screws 1 to access circuit board. Remove this LED 2 (pull out). RJ-15 Port Faceplate (back) Plug the Serial Communication 3 Cable into RJ-15 Port on the circuit board. Align the faceplate and 4 & 5 replace the 4 screws. Figure 6 Connecting the Faceplate 975-0123-01-01 Rev A 11
Inhaltszusammenfassung zur Seite Nr. 18
To connect the remote: 1. Remove the front cover of the C-Series controller by removing the four screws on the front cover of the unit. 2. Route one end of the serial communications cable (SCC) through a knockout on the controller. Use a strain relief to hold and protect the cable. 3. Plug this end of the yellow cable into the RJ-15 Port on the circuit of the controller. 4. Route the other end of the SCC to where the remote display will be located. Plug this end of the cable into RJ-15 Po
Inhaltszusammenfassung zur Seite Nr. 19
Remote (back) RJ-15 Remove these 1 Port 4 screws to access circuit board. 2 4 Serial Communications Cable Route one end of SCC through 3 (SCC) strain relief on controller. Plug the SCC into the RJ-15 Port on Route the other end of the the circuit board of the controller. SCC to the RJ-15 Port on the back of the Remote. 5 Align the original 6 Mount the display faceplate and replace up to 1,000 ft from the 4 screws. the controller. Figure 7 Connecting the Remote 975-0123-01-01 Rev A 13
Inhaltszusammenfassung zur Seite Nr. 20
Mounting the Remote (Step 3) The remote can be permanently installed in a wall or cabinet. The unit can also be flush-mounted into a rectangular opening in a wall or surface-mounted using a double-gang, non-metallic outlet box. To flush mount the remote, an opening must be cut in the backing material to allow room for the circuit board, wires, and connectors. Allow at least 1 ½ inch minimum clearance behind the circuit board for the connectors and wires. Important: Use great care when cutti