Inhaltszusammenfassung zur Seite Nr. 1
SB-1000 MANUAL
Inhaltszusammenfassung zur Seite Nr. 2
SB-1000 MANUAL Furthermore, in order to save the battery FEATURES energy, the UPS will automatically turn off 600 Watt / 1000VA capacity under backup mode if none of the connected • 3 minute back-up at full 5 amp load. equipment is activated. • 32 minute back-up with typical computer / Advanced Battery Management monitor The UPS conveys its battery’s status with the Adjustable output voltage for 110/115/120 • use of visual and audible indicators located VAC for U.S. units and 220/
Inhaltszusammenfassung zur Seite Nr. 3
SB-1000 MANUAL SB-1000 / SB-1000 E Front Panel T es t S wi t c h B a t t er y F a u l t A C N o r mal B a t t er y in u s e B y p as s O ff U P S 1 U P S 2 S il e n c e B u z z er On 1 2 3 4 5 6 7 8 4 “Battery Fault” Indicator software to support WINDOWS, DOS, The indicator will light when the battery is NOVELL operating systems. weak. Recharge the battery for at least four hours. If the light remains after recharging, 2 Phone/Fax P
Inhaltszusammenfassung zur Seite Nr. 4
T e st S w it c h B a t t er y F au lt A C N o r m a l B a t t e r y in u se B y p as s O f f U P S 1 U P S 2 S i lenc e Bu z z e r O n T E L/ M O D E M R em o t e I N P U T I N O U T P o r t B R E A K ER B Y P A S S U PS 2 U P S 1 SB-1000 MANUAL SB-1000 E Rear Panel T E L / M O D EM R e m o t e I N P U T IN O U T P o r t B R E A KE R B Y P A S S U P S 2 U P S 1 1 2 3 4 5 6 7 INSTALLATION Avoid using extension cords. If used, ma
Inhaltszusammenfassung zur Seite Nr. 5
SB-1000 MANUAL The UPSMON series software acts as OPERATION a standard RS-232 interface to perform monitoring functions, and then provides an 1) Operation check orderly shutdown of a computer in the event It is recommended that the user perform a of power failure. Moreover, UPSMON displays simulation test when using the UPS for the all the diagnostic symptoms on monitor, such first time or when adding an additional piece as Voltage, Frequency, and Battery level, etc. of equipment. Condu
Inhaltszusammenfassung zur Seite Nr. 6
SB-1000 MANUAL OTHER WARRANTIES, EXPRESS OR ONE YEAR LIMITED WARRANTY IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF Furman Sound, Inc., having its principal place MERCHANTABILITY AND FITNESS FOR of business at 1997 South McDowell Blvd., A PARTICULAR PURPOSE. Manufacturer Petaluma, CA 94954 (“Manufacturer”) warrants does not warrant against damages or defects its SB-1000 (the “Product”) as follows: arising out of improper or abnormal use of handling of the Product; ag
Inhaltszusammenfassung zur Seite Nr. 7
SB-1000 MANUAL obligation of Manufacturer with respect to the Product. If any part of this Limited Warranty is determined to be void or illegal, the remainder shall remain in full force and effect. S E R V I C E Before returning any equipment for repair, please be sure that it is adequately packed and cushioned against damage in shipment, and that it is insured. We suggest that you save the original packaging and use it to ship the product for servicing. Also, please enclose a note givi
Inhaltszusammenfassung zur Seite Nr. 8
SB-1000 MANUAL TROUBLESHOOTING The UPS has a self-protect feature that prevents it from being damaged as a result of overheating. If the temperature is higher than 131 °F (55 °C), wait for a while and let the UPS become cool. Problems Possible Cause Solution Full-time Bypass Circuit breaker button Unplug at least one piece of equipment outlets stop providing popped up as a result of from the Full-time Bypass outlets. power to the overload. Switch off UPS, wait 5 seconds, reset equipment the
Inhaltszusammenfassung zur Seite Nr. 9
SB-1000 MANUAL SPECIFICATIONS Input: Capacity: 1000VA / 600W Voltage: +/-25% at line input Frequency: 50 or 60 Hz +/-10% (auto sensing) Output: Voltage (on battery): Simulated sine wave at 110V/115V/120V or 220V/230V/240V +/- 5% Frequency (on battery): 50 or 60 Hz +/- 5% AC Line Voltage Regulation: Input Voltage Range: 90 VAC to 150 VAC (E-Version Input Voltage Range: 175 VAC to 290 VAC) Output Voltage Range: 109 VAC to 131 VAC (E-Version Output Voltage Range: 201 VAC to 252 VAC)
Inhaltszusammenfassung zur Seite Nr. 10
SB-1000 MANUAL
Inhaltszusammenfassung zur Seite Nr. 11
SB-1000 MANUAL
Inhaltszusammenfassung zur Seite Nr. 12
SB-1000 MANUAL Furman Sound, Inc. 1997 South McDowell Blvd. Petaluma, California 94954-6919 USA Phone: 707-763-1010 Fax: 707-763-1310 Web: www.furmansound.com E-mail: info@furmansound.com