Inhaltszusammenfassung zur Seite Nr. 1
USE & CARE MANUAL
THIS AIR CONDITIONER IS EQUIPPED WITH A NEW INDUSTRY
STANDARD POWER SUPPLY CORD WITH A TEST-RESET FUNCTION
READ AND SAVE THESE INSTRUCTIONS
AIR CONDITIONER
MULTI-STEP SPEED ELECTRONIC CONTROL
P/N 220202d019
SZ000400(En)-Yaokong 1 12/10/2004, 5:36 PM
Inhaltszusammenfassung zur Seite Nr. 2
ROOM AIR CONDITIONER WARRANTY Your product is protected by this warranty Your appliance is warranted by Electrolux. Electrolux has authorized Frigidaire Consumer Services and their authorized servicers to perform service under this warranty. Electrolux authorizes no one else to change or add to any of these obligations under this warranty. Any obligations for service and parts under this warranty must be performed by Frigidaire Consumer Services or an authorized Frigidaire servicer. WARRANTY FRI
Inhaltszusammenfassung zur Seite Nr. 3
Record Your Model and Serial Numbers Product Registration Record in the space provided below the model and serial numbers. On all models, the serial plate is located on the outside of the cabinet. Model No. Serial No. Register Your Product The self-addressed PRODUCT REGISTRATION CARD should be filled in completely, signed and returned to the Frigidaire Company. 2 Warranty Contents 3 Product Registration 3 Normal Sounds NOTE: This Owner’s Guide provides 4 Important Safety Instructions specific
Inhaltszusammenfassung zur Seite Nr. 4
Read all instructions before using this air conditioner. Important Safety For Your Safety Instructions Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings. The power supply cord with this air conditioner contains a current Prevent Accidents detection device designed to reduce the risk To reduce the risk of fire, electrical shock, or injury to persons when using your air conditio
Inhaltszusammenfassung zur Seite Nr. 5
To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS before operating this appliance. The power supply cord contains a current device that senses damage to the power cord. To test your Operation of Current power supply cord do the following: 1. Plug in the Air Conditioner. Device 2. The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will notice a click as the RESET button pops out. 3. Press the RESET but
Inhaltszusammenfassung zur Seite Nr. 6
NOTE: The following instructions represent the Unit Controls, the same instructions can be used for the Remote Control. Air Conditioner Features (continued) TO TURN UNIT ON: YOU WILL SEE: DO THIS: PRESS ON/ OFF BUTTON TO CHANGE TEMPERATURE YOU WILL SEE: SETTING: Note: Tap or hold either up( ) or down( ) button until the desired temperature is seen on the display. This temperature DO THIS: will be automatically maintained anywhere between 60˚F (16˚C) and 90˚F (32˚C). If you want the display to
Inhaltszusammenfassung zur Seite Nr. 7
Air Conditioner Features (continued) TO USE AUTO COOL FEATURE: YOU WILL SEE: LIGHT On DO THIS: Note: Fan starts at High Speed and adjusts to a slower speed as the room temperature dictates. For example if the room PRESS AUTO doesn’t get too warm, it will stay at the slowest speed. If the COOL room temperature rises quickly, such as a door being opened, BUTTON it will automatically go to the highest speed. The fan speeds will re-adjust back to the slowest speed as the room returns to the origin
Inhaltszusammenfassung zur Seite Nr. 8
Air Conditioner Features (continued) TIMER: DELAY STOP / START FEATURE YOU WILL SEE: TIMER SETTING LIGHT On Note: For Delay Stop, the unit must be in the On position. DO THIS: Note: For Delay Start, the unit must be in the Off position. PRESS TIMER BUTTON To adjust timer setting, tap or hold the UP arrow(^) or the DOWN arrow(V) to change delay timer at .5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start (8, 7.5,
Inhaltszusammenfassung zur Seite Nr. 9
Air Conditioner Features (continued) CHECK FILTER FEATURE: YOU WILL SEE: LIGHT On Note: This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation. The LED (light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the “Check Filter” button and the light will go off. TO TURN UNIT OFF: DO THIS: PRESS ON/ OFF BUTTON 9 SZ000400(En)-Yaokong 9 12/10/2004, 5:36 PM
Inhaltszusammenfassung zur Seite Nr. 10
Air Conditioner Features (continued) ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with. • The “Cool “ circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping. The fan will continue to run during this time. • The control will maintain the set temperature within 2 degr
Inhaltszusammenfassung zur Seite Nr. 11
Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the Care and Cleaning unit before cleaning to prevent shock or fire hazards. Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils. • Push the vent handle to the Vent Closed position (where applicable). • Open the front panel. • Grasp the filter by the center and
Inhaltszusammenfassung zur Seite Nr. 12
Before calling for service, review this list. It may save you time and expense. This list Avoid Service Checklist includes common occurrences that are not the result of defective workman-ship or materials in this appliance. OCCURRENCE SOLUTION Air conditioner will not operate. Wall plug disconnected. Push plug firmly into wall outlet. Plug Current Device Tripped. Press the RESET button. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. Contr