Inhaltszusammenfassung zur Seite Nr. 1
User Manual for:
CPS320SL / CPS375SL / CPS500SL /
CPS575SL / CPS650SL
and PowerPanel™ Software
ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT:
http://www.cyberpowersystems.com/faq_sl.htm
Inhaltszusammenfassung zur Seite Nr. 2
TABLE OF CONTENTS Description……………………. ………1 LED Indicators……………………………..7 Determining Power Requirements…..1 Troubleshooting Guide……………………8 Hardware Installation Guide………….2 Specifications………………………………8 Software Installation Guide…………..3 Battery Replacement Instructions…….….9 Software User Manual………………..4 Warranty…………………………………...10 Thank you for purchasing a CyberPower Systems Product. To enjoy all the features and benefits of this Uninterruptible Power System
Inhaltszusammenfassung zur Seite Nr. 3
CPS320SL / CPS375SL / CPS500SL / CPS575SL / CPS650SL Guaranteed Uninterruptible Power System DESCRIPTION Battery/Surge Outlets Circuit Breaker Provides three battery powered/surge outlets for connected Located on the side of the UPS, the circuit breaker serves to equipment and insures temporary uninterrupted operation provide overload and fault protection. Under normal operating of your equipment during a power failure. conditions, the circuit breaker is depressed. Full
Inhaltszusammenfassung zur Seite Nr. 4
HARDWARE INSTALLATION GUIDE 1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least four hours is recommended to insure that the battery’s maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge in both the on as well as the off position. 2. If you wish to use the software, connect the enclosed serial interf
Inhaltszusammenfassung zur Seite Nr. 5
CPS320SL / CPS375SL / CPS500SL / CPS575SL / CPS650SL Guaranteed Uninterruptible Power System POWERPANEL™ SOFTWARE INSTALLATION GUIDE (Note: Use of the software is optional. The UPS will provide surge suppression and battery backup without the software. You must use the software if you wish to have the automatic shutdown feature). FOR WINDOWS 95/98/Me 1. Turn the UPS off and unplug it. 2. Connect the serial interface cable to the UPS and an open serial port on the back of the c
Inhaltszusammenfassung zur Seite Nr. 6
13. Click Install. 14. Follow the on-screen instructions. 15. Once the software is installed, remove the floppy disk and restart your computer. When your computer restarts, the PowerPanel™ software will appear on your screen for a few seconds, and then minimize. It will appear as a blue and white battery icon located in the system tray, near the clock. POWERPANEL™ SOFTWARE USER MANUAL OVERVIEW PowerPanel™ version 2.03 or greater is designed for use with Windows 95, Windows
Inhaltszusammenfassung zur Seite Nr. 7
CPS320SL / CPS375SL / CPS500SL / CPS575SL / CPS650SL Guaranteed Uninterruptible Power System 3. Time Between Power Failure and Shutdown Process: This user adjustable setting determines how long the UPS will run on battery before starting to shut down the system. If this is not checked, the unit will run on battery until the low battery condition is met (2 minutes of backup time remaining), and then start the shutdown process. If the low battery condition is met before this timer reache
Inhaltszusammenfassung zur Seite Nr. 8
Uninterruptible Power Supply is installed on. Click OK. Acknowledge the message that the UPS is in an unknown state and exit to the desktop. USING THE WINDOWS 2000 UPS SERVICE If you are running Windows 2000, you may choose to run the Windows 2000 UPS service instead of PowerPanel™. You can run either PowerPanel™ or the Windows 2000 UPS service, but not both. To Configure the Windows 2000 UPS Service: 1. Click on Start, point to Settings, then Control Panel. 2. Double-cli
Inhaltszusammenfassung zur Seite Nr. 9
CPS320SL / CPS375SL / CPS500SL / CPS575SL / CPS650SL Guaranteed Uninterruptible Power System DEFINITIONS FOR ILLUMINATED LED INDICATORS CONDITION On Off Set Off Off On/Off Set Two Beeps Utility Failure- the UPS is providing power to battery power-supplied outlets from its battery. Off On/Off Set Rapid Utility Failure- The UPS is providing Beeps battery power. Rapid beeps indicate the unit will run out of power shortly. Off Off Up Two Beeps System Overload- Occurs
Inhaltszusammenfassung zur Seite Nr. 10
TROUBLESHOOTING Problem Possible Cause Solution Full-time surge protection Circuit breaker has tripped Turn the UPS off and unplug at least one piece of outlets stop providing due to an overload. equipment. Wait 10 seconds, reset the circuit power to equipment. breaker by depressing the button, and then turn the UPS on. The UPS does not Battery not fully charged. Recharge the battery by leaving the UPS plugged perform expected runtime. in. Battery is slightly worn C
Inhaltszusammenfassung zur Seite Nr. 11
CPS320SL / CPS375SL / CPS500SL / CPS575SL / CPS650SL Guaranteed Uninterruptible Power System EXPECTED RUNTIME IN MINUTES CPS320SL CPS375SL CPS500SL CPS575SL CPS650SL Desktop PC with 15” Monitor 6 – 9 8 – 12 10 – 14 17 – 21 18 – 24 Desktop PC with 17” Monitor 4 – 6 6 - 9 8 – 12 15 – 19 16 – 22 Desktop PC with 21” Monitor Not Advised Not Advised 6 - 10 13 – 17 14 – 19 REPLACING THE BATTERY CAUTION! Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery
Inhaltszusammenfassung zur Seite Nr. 12
Limited Warranty And Power Control Guarantee In purchasing a 320SL, 375SL, 500SL, 575SL or 650SL in the United States or Canada, the original end user receives a Limited Warranty and CyberPower’s Power Control Guarantee from Cyber Power Systems (USA), Inc. (for ease of reading, referred to as “CyberPower”). The Limited Warranty and the Power Control Guarantee are intended to be the initial end-user’s exclusive rights and remedies. The Limited Warranty and the Power Control Guara
Inhaltszusammenfassung zur Seite Nr. 13
CPS320SL / CPS375SL / CPS500SL / CPS575SL / CPS650SL Guaranteed Uninterruptible Power System POWER CONTROL GUARANTEE If you are the Initial Purchaser and the Product is still covered by the Limited Warranty, the Power Control Guarantee provides protection for damage to equipment connected to the Product (“Connected Equipment”), subject to certain terms and limitations. The Power Control Guarantee is not “first dollar” coverage. CyberPower’s obligation is reduced by any amounts that
Inhaltszusammenfassung zur Seite Nr. 14
3. The amount(s) of all payment you have or are entitled to receive from insurance, other warranties, extended warranties, or from other sources or persons for the Connected Equipment or damage to such equipment so that CyberPower’s maximum liability shall be reduced to reflect all such other payments or sources of recovery: CyberPower 320SL-$30,000.00 CyberPower 375SL-$35,000.00; CyberPower 500SL-$40,000.00; CyberPower 575SL-$45,000.00; CyberPower 650SL-$100,000.00. If C
Inhaltszusammenfassung zur Seite Nr. 15
CPS320SL / CPS375SL / CPS500SL / CPS575SL / CPS650SL Guaranteed Uninterruptible Power System DO NOT USE FOR MEDICAL OR LIFE SUPPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES. CyberPower does not sell the Products for use in high-risk activities. The Product is not designed or intended for use in hazardous environments requiring fail-safe performance, including the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, weapons systems, life
Inhaltszusammenfassung zur Seite Nr. 16
FCC Notice This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee