Inhaltszusammenfassung zur Seite Nr. 1
Instructions
MICRO HD CAMERA
DZ-VCA3U
Model No.
Serial No.
LYT1053-001B
Inhaltszusammenfassung zur Seite Nr. 2
Contents Feature Applications.......................................................................... 3 Thank you for purchasing the Precautions on installing medical electrical equipment (Safety and hazard prevention) ........................................ 3 DZ-VCA3U MICRO HD CAMERA. Safety precautions ............................................................... 4 Important product safety instructions ............................... 5 Precautions..........................................
Inhaltszusammenfassung zur Seite Nr. 3
Applications ATTENTION: Micro HD camera system can be used for following Follow and obey all warnings and instructions marked application; Endoscope operation in OR. on your product and its operating instructions. For your (This system should only be operated by doctors or safety, please read all the safety and operating instruc- authorized persons.) tions before you operate this product and keep this Above application, the system can supply HD and SD booklet for future reference. signals to HD/
Inhaltszusammenfassung zur Seite Nr. 4
Safety precautions Please Read Before Use WARNING: WARNING: The use of ACCESSORY This MICRO HD CAMERA should equipment not complying with be used with a power supply of the equivalent safety AC 120 V , 60 Hz only. requirements of this equipment To prevent electric shocks and may lead to a reduced level of fire hazards, DO NOT use any safety with the resulting system. other power supply. Consideration relating to the choice of accessories shall include: – use of the accessory in the WARNING: vic
Inhaltszusammenfassung zur Seite Nr. 5
Important product safety instructions INSTALLATION AND DISPOSAL USE 1. Grounding or Polarization 1. Accessories Precautions should be taken so that the grounding or To avoid personal injury: polarization of an appliance is not defeated. • Do not place this product on an unstable cart, stand, tripod, bracket, or table. It may fall, causing serious 2. Power Sources injury to a child or adult, and serious damage to the Operate your product only from the type of power product. source indicated on th
Inhaltszusammenfassung zur Seite Nr. 6
Important product safety instructions (Continued) SERVICING STERILIZATION: The camera head with camera cable and endoscope 1. Servicing adapter can be sterilized with ethylene oxide (EO). Should the product fail to work normally, do not attempt to fix it yourself. Please rely on a qualified EO gas parameters are as follows. service person. Ethylene oxide gas : 10 % EO and 90% Inert Note: gases. Before returning the camera head, endoscope Temperature : 40 °C to 60° C (104° F to adapter, be sure t
Inhaltszusammenfassung zur Seite Nr. 7
Precautions Safety precautions If a problem develops concerning the opera- tion of this product while it is being employed L Do not damage or modify the power cable. Doing so as an endoscopy system during surgery, etc., could result in current leakage or electric shock. take the appropriate action as described L To protect the camera and avoid electric shock below: hazards, always disconnect the power cord of the camera L Problem with the endoscope control unit from the AC outlet when the camer
Inhaltszusammenfassung zur Seite Nr. 8
Precautions (Continued) Inspection and maintenance Phenomena peculiar to CCDs The product and its components must be inspected Pale, vertical streaks regularly by a specialist. (The product should be inspected appear in the picture. once a year). Monitor screen Camera Head Section High-intensity subject 1. Leave installation of the product to a specially trained (electric light, lamp, service personnel. the sunlight, etc.) 2. Connect the optional endoscope adapter DZ-E3U or DZ-E33U to lens moun
Inhaltszusammenfassung zur Seite Nr. 9
Connections L Connection example DT-V1900CG (Optional) Endoscope adapter (Optional) Endoscope (Commercially available) UNDER PULSE COLOR MUTING DEGAUSS SCAN CROSS OFF POWER SLOT 1 SLOT 2 SLOT 3 A B C D E F VOLUME MENU SCREENS ASPECT AREA INPUT SELECT CHECK MARKER Camera head SR-W7MAU (Optional) (W-VHS) Connector Cap Video HD S(Y/C) Out (Y, PB, PR) Out Front GENLOCK NTSC OUT SXGA OUT HD OUT IN/OUT ~AC IN DV Y GBR Connector PB CAMERA Y/C (S) PR VBS To each equipment Isolation transformer AA-V3
Inhaltszusammenfassung zur Seite Nr. 10
Name of parts and their functions Camera control unit (front panel) 5 OUTPUT LEVEL WHITE BALANCE MENU SETTING POWER 2 AUTO MANUAL AUTO MANUAL ON OFF SETTING CAMERA ON I ADJUST RED BLUE GAIN SHUTTER ENHANCE FREEZE BAR OFF O 3 4 6 1 [POWER] power switch and power indication [WHITE BALANCE] white balance control sec- 1 4 LED tion When switching power on again after it is just Adjust white balance automatically or manually switched off: Wait for more than 5 seconds before switching it on. Menu co
Inhaltszusammenfassung zur Seite Nr. 11
Camera control unit (rear panel) 1 GENLOCK NTSC OUT SXGA OUT HD OUT IN/OUT ~AC IN DV Y GBR PB Y/C (S) PR VBS 2 3 4 5 6 7 [GENLOCK IN/OUT] sync signal input/output 5 1 [AC INPUT] power input connector Input/output of composite sync signal for external To input AC120V. sync. (menu-based switching). 2 Equal-potential connector [SXGA OUT] SXGA output section 6 Output of progressive scan GBR signal. SXGA output signal cannot be displayed on the DT- 3 Cover for extension slot V1900CG.Use the monitor t
Inhaltszusammenfassung zur Seite Nr. 12
Names of parts and their functions (continued) Output level control section OUTPUT LEVEL 1 AUTO MANUAL OUTPUT LEVEL WHITE BALANCE MENU SETTING POWER AUTO MANUAL AUTO MANUAL ON OFF CAMERA SETTING ADJUST ON I GAIN SHUTTER ADJUST RED BLUE GAIN SHUTTER ENHANCE FREEZE BAR 2 OFF O 3 4 SHUTTER UP/SHUTTER DOWN button 1 GAIN switch 4 Using the [SHUTTER UP] / [SHUTTER DOWN] button, the [AUTO] following setting is possible: 1/60, 1/100, 1/175, 1/250, 1/375, Adjusts gain automatically. 1/500, 1/1000, 1/
Inhaltszusammenfassung zur Seite Nr. 13
White balance control section WHITE BALANCE 5 AUTO MANUAL OUTPUT LEVEL WHITE BALANCE MENU SETTING SETTING POWER AUTO MANUAL AUTO MANUAL ON OFF 6 CAMERA SETTING ON I ADJUST RED BLUE RED BLUE GAIN SHUTTER ENHANCE FREEZE BAR OFF O 7 WHITE BALANCE switch 5 6 SETTING button R/B button 7 [AUTO] When set to this position, the camera is automatically set to a pre-adjusted white balance. To automatically readjust the while balance, use [SETTING] button 6 . [MANUAL] When adjusting the white balance ma
Inhaltszusammenfassung zur Seite Nr. 14
Names of parts and their functions (continued) Mode control section ENHANCE FREEZE BAR OUTPUT LEVEL WHITE BALANCE MENU SETTING POWER AUTO MANUAL AUTO MANUAL ON OFF SETTING CAMERA ON I ADJUST RED BLUE GAIN SHUTTER ENHANCE FREEZE BAR OFF O 8 9 10 8 ENHANCE button 10 BAR button To set enhance. By pressing this button, LED will light up, and the enhance By pressing this button, LED will light up, and Full Color Bar will be functional. Press it again, then LED will light off and the will be displa
Inhaltszusammenfassung zur Seite Nr. 15
L MENU [INDICATION1] menu Set the display on the top left of HD OUT and SXGA OUT screen. Selection items and functions are as follows: . IND I CAT ION1 ID/CODE IND I CAT ION2 GA I N&SHUT IND I CAT ION3 OF F Selection items Functions ID/CODE DA T E&T IME ID/CODE Displays the content set under ID/CODE SYNC menu. GAIN&SHUT Displays the gain value and shutter value. OFF No display [INDICATION2] menu Set the display on the top right of HD OUT and SXGA OUT screen. Selection items and functions are as
Inhaltszusammenfassung zur Seite Nr. 16
Names of parts and their functions (continued) [ID/CODE] menu Edit ID/CODE that can be displayed on the screen. • Select from INDICATION 1, 3 menu to see if it can be displayed. • Message is up to 22 alphanumeric characters. • Characters that can be used: A-Z, 0-9, ., :, -, /, and space. [DATE&TIME] menu To change date and time setting, and date display format. [DATE] sub-menu Use the [LEFT]/[RIGHT] button to select the part of the date to be changed (the numbers will blink), and use the [UP]/[D
Inhaltszusammenfassung zur Seite Nr. 17
Basic operation White balance adjustment a AUTO While watching the monitor, shoot a white object with full screen under the same lighting condition as actual shooting. SETTING button Set the WHITE BALANCE switch to [AUTO]. When you press and hold [SETTING] button, [AUTO WHITE] WHITE BALANCE will blink at the upper left corner of the screen. WHITE BALANCE When white balance adjustment is complete, the indication switch AUTO MANUAL changes to [AUTO WHITE OK]. SETTING If the indication at the uppe
Inhaltszusammenfassung zur Seite Nr. 18
Basic operation (Continued) Operation of Micro HD camera Check system operation according to the following procedures. Connector Cap Mark (Red) Connector 1. Insert the camera connector while aligning it to the red mark as shown on the left figure. Camera head When cap is connected to the camera connector: Turn the cap counterclockwise to remove it. 2. Connect the endoscope adapter to the C mount of camera CAMERA head. 3. When operating this system, set the switches on the CCU panel a
Inhaltszusammenfassung zur Seite Nr. 19
Connector a Camera cable connector input/output terminals (CCU side) 1. Sync signal output 2. Sync signal output 3. Shutter speed control signal 4. Shutter speed control signal 12 1 11 2 5. Shutter speed control signal 13 10 14 3 15 16 6. Control signal input 9 18 17 4 19 8 5 7. DC 15V output 7 6 8. DC 5V output 9. GND 10.–7.5V output 11.B signal input 12.GND 13.G signal input 14.GND 15.R signal input 16.GND 17.Basic clock input 18.GND 19.NC Symbols indicated on this equipment have the following
Inhaltszusammenfassung zur Seite Nr. 20
Specifications Design and specifications subject to change without notice. MICRO HD CAMERA DZ-VCA3U Camera head section L Image sensing device : 1/3-inch PS-CCD (350,000 pixels) L Shooting system : 3-CCD system L Color separation optical system : 1/3-inch F1.4 3-color separation prism L Number of effective pixels : 659 (horizontal) x 494 (vertical), 330,000 pixels approximately L Camera output : 19 pins L Lens mount : Standard C mount ( flange back: 17.526 mm in air) L Dimensions : Camera head;