Inhaltszusammenfassung zur Seite Nr. 1
COMPLIANCE INFORMATION
UL Listed
C-UL Listed (Canada)
T1/E1 Twisted-Pair Copper to Fiber
CISPR22/EN55022 Class A + EN55024
CE Mark
Media Converters
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
SSDTF10xx*-100
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and
Inhaltszusammenfassung zur Seite Nr. 2
100BASE-FX 10/100SX 10/100TX 100BASE-FX 10BASE-FL 10BASE-T DB-9 TERM INIT 12C 12C-1 SSDTF10xx IN THE NETWORK TECHNICAL SPECIFICATIONS Standards Emissions: CISPR A NOTE: THE SSDTF10xx REQUIRES A CSU BETWEEN THE MEDIA CONVERTER AND THE PUBLIC TELEPHONE NETWORK. T1/E1 Physical Layer: ITU-T, ANSI, AT&T, ETSI Dimensions 2.9" x 4.8" x 1.4" Weight 8 oz (approximate) Power Source 7.5-15.9 VDC AC Adapter Power Consumption 5 watts T1 Network Extension Power Supply Requirements Replace power supply with
Inhaltszusammenfassung zur Seite Nr. 3
Ω Ω Dry-Contact Relay CABLE SPECIFICATIONS (continued) RJ-45 dry-contact relay opens if power, signal detect/copper or signal Twisted-Pair Copper Cable detect/fiber are lost. Operational rating on pins 3 and 6: 0-30VDC maximum 1A Twisted pair connection requires two active pairs. The two active pairs in a T1/E1 network are pins 1 & 2 and pins 4 & 5. Use only dedicated Relay wire pairs (such as blue/white & white/blue, orange/white & 3 RJ-45 white/orange) for the active pins. Category 3 or better
Inhaltszusammenfassung zur Seite Nr. 4
INSTALLATION CABLE SPECIFICATIONS CAUTION: Wear a grounding device and observe electrostatic discharge Fiber Cable precautions when setting switch and when installing Media Converter Slide-in- Bit error rate: ≤10-9 Module in the Media Conversion Center. Failure to observe this caution could MULTIMODE result in damage to, and subsequent failure of, the Media Converter Slide-in- Module. Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber Optional: 100 / 140 µm multimode fiber Set Loopbac
Inhaltszusammenfassung zur Seite Nr. 5
Ω Ω NOTE: LEFT SWITCH SET FAULT ISOLATION and CORRECTION T1 must be selected (LEFT 1 2 3 4 1 2 3 4 SWITCH SET #4 UP) for RIGHT If the media converter fails, isolate and correct the failure by determining the SWITCH SET to have any effect. answers to the following questions and then taking the indicated action: If E1 is selected (LEFT SWITCH SET toward chassis toward network connectors 1. Is the P(o)W(e)R LED on the media converter illuminated? #4 DOWN), RIGHT SWITCH SET
Inhaltszusammenfassung zur Seite Nr. 6
INSTALLATION (continued) OPERATION After installation, the media converter should function without operator Install Cable intervention. COPPER Status LEDs T1 100 OHM (RJ-45 CONNECTOR) Use the status LEDs to monitor media converter operation in the network. 1. Locate or build twisted-pair cables that are compliant with specifications on page 10, with RJ-45 plug connectors at both ends. SDC Signal Detect/Copper - Steady LED indicates twisted-pair copper link is up. SDC SDF PWR 2. Ensure that MD