Inhaltszusammenfassung zur Seite Nr. 11
Replacing Power Supply Modules User-Replaceable Power Supply Modules While power supply modules are redundant, failed power supply modules should promptly be replaced to maintain network integrity and prevent data loss. To replace a power supply module: 1. Disconnect the power source from the power supply module. 2. Remove the screws of the retainer plate (on some AC modules). 3. Move the Power Supply Release switch toward the right or unscrew captive release screw. 4. Before graspin
Inhaltszusammenfassung zur Seite Nr. 12
Dual DC, Part Number 850-10954-2DC Dual AC, Part Number 850-10956-2AC NOTE Do not mix AC and DC power supply modules. 8
Inhaltszusammenfassung zur Seite Nr. 13
iMediaChassis/20 Specifications Input Specifications Dual AC Input: 100 to 240V±10%, 47-63Hz, 6.3A Dual AC Dual DC Input: -38 to -72V DC 11A max (per module) Operating Temperature: 0° C to 50° C (32° F to 122° F) Storage Temperature Dual AC: -20° C to 80° C (-4° F to 176° F) Dual DC: -20° C to 60° C (-4° F to 140° F) Humidity: Dual AC & DC: 20 to 90% (non-condensing at 40° C) Shipping Weight Dual AC: 30 lbs (13.6 kg) Dual DC: 29 lbs (13.15 kg) Dimensions: 5.2"
Inhaltszusammenfassung zur Seite Nr. 14
About the iMediaChassis/6 The iMediaChassis series is a modular chassis platform designed for use with IMC Networks’ Simple Network Management Protocol (SNMP) manageable series of modules. The iMediaChassis/6 is 1U high, Rackmountable, capable of offering redundant power supply modules, as well as an SNMP Management Module. iMediaChassis/6 Features The iMediaChassis/6 series offers a line of models including single AC, single DC and dual AC. It offers features such as end-user replace
Inhaltszusammenfassung zur Seite Nr. 15
Both power supply modules malfunction Both power supply modules are powered down When the AC line fails SNMP Write Lock There is an SNMP Write Lock switch located above the SNMP module slot on the front of the iMediaChassis/6. The SNMP Write Lock switch prevents a new management board from re-configuring the application module settings (e.g., the status of features such as LinkLoss, FiberAlert, Force mode, etc.) made via SNMP on any previous Management Modules. NOTE Leave th
Inhaltszusammenfassung zur Seite Nr. 16
Installing the iMediaChassis 6 Install the chassis first before installing any modules into an iMediaChassis. When installing the chassis, be sure to observe the following precautions to prevent electrical or mechanical damage: Stay within the chassis’ power rating to prevent overload of supply circuits or 1. damage to any overcurrent protection and supply wiring. 2. Maintain reliable ground, especially when connecting to a power strip instead of directly to a branch circuit. 3. Pro
Inhaltszusammenfassung zur Seite Nr. 17
SNMP Management Modules include two twisted pair ports, one for management and one reserved for future use. The Management Module also features a DB-9 serial port, and supports SNMP V1/V2c. Installing Management and Application Modules Installing Applications Modules To install a module: 1. Remove the blank bracket (if present) covering the slot where the module will be installed. IMC Networks recommends installing blank brackets in unused module slots. 2. Slide the module into the
Inhaltszusammenfassung zur Seite Nr. 18
DC Power Wiring, Replacing Power Supply Modules and Fans DC Power Supply Wiring Instructions The following diagram shows the wiring configurations for -48 VDC power supply modules for the iMediaChassis/6. User-Replaceable Power Supply Modules The iMediaChassis/6 ships from IMC Networks with one or two power supply modules installed depending on the model. Chassis ordered with one power supply come with a filler tray installed in the second slot. To install a second power supply: 1.
Inhaltszusammenfassung zur Seite Nr. 19
iMediaChassis/6 Specifications Input Specifications Dual AC Input: 100/240VAC 47-63Hz 1.8A @10VAC 115V @ 1.6A and 230V @ 0.8A (single) Dual DC Input: 48VDC, 3.3A Operating Temperature: AC: -25° C to 50° C (-130° F - 122° F) DC: -40° C to 100° C (-40° F - 212° F) Storage Temperature: AC: -40° C to 85° C (-40° F - 185° F) DC: -55° C to 125° C (-67° F - 257° F) Humidity: 5 - 90% (non-condensing); 0-10,000 ft. altitude Shipping Weight: 13 lbs (5.90 kg) Dimen
Inhaltszusammenfassung zur Seite Nr. 20
About the iMediaChassis/3 The iMediaChassis series is a modular chassis platform designed for use with IMC Networks’ Simple Network Management Protocol (SNMP) manageable series of modules. The iMediaChassis/3 is a 1U high, a Rackmountable, capable of offering redundant power supply modules, as well as an SNMP Management Module. iMediaChassis/3 Features The iMediaChassis/3 series offers a line of models including single AC, single DC, dual AC and dual DC. All contain internal fixed po
Inhaltszusammenfassung zur Seite Nr. 1
iMediaChassis series
iMediaChassis/20
iMediaChassis/6
iMediaChassis/3
Operation Manual
Inhaltszusammenfassung zur Seite Nr. 2
FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful inte
Inhaltszusammenfassung zur Seite Nr. 3
Table of Contents FCC Radio Frequency Interference Statement ........................................................ii Warranty................................................................................................................ii About the iMediaChassis/20...................................................................................1 iMediaChassis/20 Features ....................................................................................1 Alarm Reset, Last Gasp and Te
Inhaltszusammenfassung zur Seite Nr. 4
About the iMediaChassis/3...................................................................................16 iMediaChassis/3 Features ....................................................................................16 Alarm Reset, Last Gasp, and Temperature Gauge ............................................16 Alarm Reset Switch .........................................................................................16 Last Gasp Alarm......................................................
Inhaltszusammenfassung zur Seite Nr. 5
About the iMediaChassis/20 The iMediaChassis series is a modular chassis platform designed for use with IMC Networks’ Simple Network Management Protocol (SNMP) manageable series of modules. The iMediaChassis/20 is a 3U high, Rackmountable chassis that features 20 slots for installing application series modules plus an additional slot for installing an SNMP Management Module. Some iMediaChassis/20 models are capable of redundant power supply modules. Power supply modules are user-repla
Inhaltszusammenfassung zur Seite Nr. 6
Reset Alarm Switch When one power supply module malfunctions, an audible alarm sounds indicating the loss of the power module. The alarm can be silenced by pressing the Reset Alarm switch, located next to the power connector on the power supply module. If this occurs, remove and replace the power supply module immediately. (LEDs on the Management Module and the power supply module itself also indicate power supply module failures.) Last Gasp Alarm The iMediaChassis series includes
Inhaltszusammenfassung zur Seite Nr. 7
The SNMP Management Module can be removed and replaced as necessary. Refer to the SNMP Management Module manual for complete instructions about how to configure and operate. If an SNMP Management Module is installed, refer to the LED panel below for indicators of Link, Temperature, Power supply modules and other functions. SNMP Management Module LEDs The SNMP Management Module features several LEDs. The LED functions are: LNK/ACT Glows green when a link is established on port. Blin
Inhaltszusammenfassung zur Seite Nr. 8
Installing the iMediaChassis/20 Install the chassis first before installing any modules into an iMediaChassis. When installing the chassis, be sure to observe the following precautions to prevent electrical or mechanical damage: 1. Stay within the chassis’ power rating to prevent overload of supply circuits or damage to any overcurrent protection and supply wiring. 2. Maintain a reliable ground, especially when connecting to a power strip instead of directly to a branch circuit. 3. Pr
Inhaltszusammenfassung zur Seite Nr. 9
Wiring Instruction Guidelines for iMediaChassis/20-2DC 1. Connection of a suitable grounding conductor to the grounding terminal at each power supply module (a minimum 14AWG copper conductor should be suitable based on a 15A circuit breaker requirement). 2. Connection of suitable supply wiring to the plus and minus terminals at each power supply module (a minimum 14AWG copper conductors is considered suitable based on the 11A input maximum). The input terminal block at the power suppl
Inhaltszusammenfassung zur Seite Nr. 10
Installing SNMP Management and Application Modules To install a module: 1. Remove the blank bracket (if present) covering the slot where the module will be installed. IMC Networks recommends installing blank brackets in unused module slots. 2. Slide the module into the chassis using the card guides. 3. Secure the module to the chassis by tightening the captive screw. (Refer to the documentation shipped with the module for configuration information.) 4. When installing modules observe