5SX_ LANlink Router Option User Manual WARNING - BEFORE INSTALLATION, PLEASE REFER TO SAFETY INSTRUCTIONS IN APPENDIX A, AND EMC INSTRUCTIONS IN APPENDIX C Certified Compliant in the EC, when fitted in accordance with the installation instructions, against the following directives/standards: Low Voltage Directive (73/23/EEC and amendment 93/68/EEC) EN60950 : 1992 (Safety) Electromagnetic Compatibility directive (89/336/EEC and subsequent amendments to date): EN55022 : 1994 (Emissions) EN50082-
Inhaltszusammenfassung zur Seite Nr. 3
CONTENTS 1 INTRODUCTION.................................................................... 6 1.1 Functional Overview............................................................................. 7 1.2 Typical Applications ............................................................................. 7 2 USE AND CONFIGURATION................................................ 9 2.1 Router Configuration ............................................................................ 9 2.2 Supervisor Termi
Inhaltszusammenfassung zur Seite Nr. 4
4.2.4 IPX: SAP TABLE ......................................................................... 27 4.2.5 SHOW TRAFFIC DETAILS......................................................... 28 4.3 NETWORK LOADING........................................................................ 28 4.4 REMOTE MANAGEMENT.................................................................. 29 4.4.1 TELNET OUT .............................................................................. 29 4.4.2 NAME SERVER CONFIGURATIO
Inhaltszusammenfassung zur Seite Nr. 5
GLOSSARY ADPCM Adaptive Differential Pulse-Code Modulation ARP Address Resolution Protocol ARPA Advanced Research Projects Agency ASCII American Standard Code for Information Interchange BER Bit Error Rate BOOTP Bootstrap Protocol bps bits per second CHAP Challenge Handshake Authentication Protocol CRC Cyclic Redundancy Check D&I Drop and Insert DNS Domain Name Server EEPROM Electrically Erasable Programmable Read-Only Memory FAS Frame Alignment Synchronisation GND Ground ICMP Internet Control M
Inhaltszusammenfassung zur Seite Nr. 6
Echo LANlink Router Option User Manual 1 INTRODUCTION This user manual describes installation, configuration and operation of the Echo LANlink Multiplexer Router option, and must be referred to in conjunction with the Echo LANlink Multiplexer User Manual. The Echo LANlink is an E1 time division multiplexer (TDM) operating at 2Mbps compliant with both EUROPEAN and UK G.703 communications standards. The Router Option card adds the capability of connecting two Local Area Networks (LANs), via the E1
Inhaltszusammenfassung zur Seite Nr. 7
The Router Option card is easily configured using the management terminal connected to the Echo LANlink from either end of the link, or through Telnet at a relevant workstation either LAN. 1.1 Functional Overview The Router Option card supports both transceiver connection (AUI port) and hub (10BASE-T port) connection to a 10MHz Ethernet LAN. Ethernet frames are transported to/from the remote LAN using some or all of the main communications link bandwidth. The bandwidth is allocated in 64Kbps tim
Inhaltszusammenfassung zur Seite Nr. 8
the Branch Office could access the Headquarters General Server via the Echo LANlink, but accesses to the Finance Server could be stopped using subnet masking in the Echo LANlink. Figure 2 Restrictive Firewall Example In addition to the features of the router, all the existing functions of the Echo LANlink are still available. This means that as well as connecting two remote LANs, the Echo LANlink can also carry PABX voice traffic (using D&I option card or ADPCM option card), and data traffic bet
Inhaltszusammenfassung zur Seite Nr. 9
2 USE AND CONFIGURATION This section covers connection and set-up of the Echo LANlink Router Option, and must be used in conjunction with the Echo LANlink User Manual. If you are not familiar with the general configuration procedure for the Echo LANlink, please refer to that manual before reading further and attempting to configure the Router Option. 2.1 Router Configuration The Router is initially configured using an asynchronous terminal, or PC using a suitable terminal emulation package such
Inhaltszusammenfassung zur Seite Nr. 10
If you are using a terminal from this list type y , or alternatively press n to enter another type: supported terminal types are shown in Figure 3 - type one of them in to select a suitable terminal type and press VT100 FALCO SUNVIEW WYSE50 A210 VT220 SUN TVI925 VT320 TVI910 VT420 Figure 3 Supported Terminal Types Once a terminal type has been selected, the main menu screen shown in Figure 4 will be displayed. Using the keyboard arrow keys you should be able to move the
Inhaltszusammenfassung zur Seite Nr. 11
2.4 Router Management Selecting ROUTER MANAGEMENT from the main menu allows the user to configure the router. The router management screen is shown in Figure 5. Refer to Section 4 for details on each menu option. +-------------------------------------------------------------------------------+ | ROUTER: S1234 EXIT | +-------------------------------------------------------------------------------+ UNIT STATUS TRAFFIC A
Inhaltszusammenfassung zur Seite Nr. 12
+-------------------------------------------------------------------------------+ | WAN IP FILTER 1 - WAN IP FILTER 1: S1234 EXIT | | ADD EDIT DELETE CLEAR NAME | +-------------------------------------------------------------------------------+ ENTER THE SOURCE I.P. ADDRESS (RETURN = ALL): LINE SRC ADDR SRC MASK DEST ADD DEST MASK PROT S.PRT D.PRT RSLT Figure 6 Entering a Parameter Echo LANlink R
Inhaltszusammenfassung zur Seite Nr. 13
2.5 Multiplexer Management Selecting MULTIPLEXER MANAGEMENT from the main menu allows the user to configure the multiplexer functions. If another user is currently accessing the multiplexer management page (e.g. via a Telnet session) this will be indicated next to the menu item. Only one session is allowed access to the multiplexer functions at any one time. If NONE is displayed the user is free to enter multiplexer management. If an IP address is displayed, then this is the address of the user
Inhaltszusammenfassung zur Seite Nr. 14
Figure 8 shows an example timeslot set-up with 512Kbps allocated to channel 1, 320Kbps allocated to channel 2, and 1152Kbps allocated to the router. 2 MEGABIT E1 MULTIPLEXER V1.04 ================================ 00:00 25/12/97 =============================== Main Link (UK) : SYNCHRONISED Exit to Router: Mode : NORMAL * Nx64 Channels : 2 + ROUTER Framing : CRC4 D&I Channels
Inhaltszusammenfassung zur Seite Nr. 15
2.6.1 MAIN LINK CARRIER LOSS The local Multiplexer cannot identify a valid synchronisation sequence (FAS, CRC4 etc) from the remote multiplexer. 2.6.2 D/I CARRIER LOSS The Multiplexer cannot identify a valid synchronisation sequence (FAS, CRC4 etc) from the unit attached to the D&I port. 2.6.3 REMOTE ALARM The unit attached to the D&I port is generating an alarm in the framing information, that is, it is reporting that it has a problem. 2.6.4 Nx64 CHANNEL x CONTROL DISAFFIRMED One of the channel
Inhaltszusammenfassung zur Seite Nr. 16
2.6.9 ROUTER WAN LINK STATUS The status of the link between the two routers is displayed. Echo LANlink Router Option User Manual Issue 1.0 04 December 1997 Page 16 of 59
Inhaltszusammenfassung zur Seite Nr. 17
3 INSTALLATION WARNING – Refer to Appendix A for Safety Instructions. WARNING - The multiplexer must be disconnected from the power supply and all peripheral connections before opening. 3.1 Opening the Multiplexer With the power cord and all peripherals DISCONNECTED, the screws on the left, right and top of the multiplexer are removed using a Pozidrive screwdriver to gain access to the interior of the multiplexer. This allows installation of the option cards J15 J10 LK13 Figure 9 Echo LANlink Ba
Inhaltszusammenfassung zur Seite Nr. 18
3.2 Internal Link LK13 Locate the internal connector LK13 on the motherboard (refer to Figure 9). This will be fitted with shorting links if the Echo LANlink was supplied without the Router Option. Remove the shorting links before fitting the Router Option. The links may be repositioned on one pin for storage. 3.3 Installing the Router Option Remove the option blanking plate above the CH 1 and CH2 connectors on the rear panel of the multiplexer. The blanking plate may be discarded if not require
Inhaltszusammenfassung zur Seite Nr. 19
3.4 Testing Replace the cover and screws before powering up the unit. Correct installation of the Router Option may be confirmed by the login prompt (see section 2.3) appearing on the terminal screen. If the red error LED on the front panel is on, this indicates hardware fault has occurred. In this case, disconnect the power cable and check the installation of the Router Option is correct. 3.5 Data Connections The Ethernet connection is made using either the AUI (15-way D-type – see Appendix E)
Inhaltszusammenfassung zur Seite Nr. 20
3.7 Quick Configuration The first stage in configuration is to allocate some bandwidth of the communication link to the router. The second stage is to configure the SERVICE SETUP to allow communication between the two routers. 3.7.1 Multiplexer Configuration From the main menu enter MULTIPLEXER MANAGEMENT. Allocate bandwidth to the router by entering ‘R’ in any free timeslot positions near the bottom of the screen. Each timeslot allocated will contribute 64Kbps of bandwidth to the router. Save