Inhaltszusammenfassung zur Seite Nr. 1
1002rp Server Hardware Installation
CallPilot
Release 4.0
Document Number: 555-7101-205
Document Version: Standard 1.07
October 2006
Inhaltszusammenfassung zur Seite Nr. 2
Standard 1.07 Copyright © 2006 Nortel Networks. All Rights Reserved. The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel Networks. The
Inhaltszusammenfassung zur Seite Nr. 3
October 2006 CRYSTAL REPORTS is a trademark of Seagate Software Inc. EUDORA is a trademark of Qualcomm. eTrust and InoculateIT are trademarks of Computer Associates Think Inc. DIRECTX, EXCHANGE.NET, FRONTPAGE, INTERNET EXPLORER, LINKEXCHANGE, MICROSOFT, MICROSOFT EXCHANGE SERVER, MS-DOS, NETMEETING, OUTLOOK, POWERPOINT, VISUAL STUDIO, WINDOWS, WINDOWS MEDIA, and WINDOWS NT are trademarks of Microsoft Corporation. GROUPWISE and NOVELL are trademarks of Novell Inc. LOGITECH is a trademark of L
Inhaltszusammenfassung zur Seite Nr. 4
Standard 1.07 WINZIP is a trademark of Nico Mark Computing, Inc. XEON is a trademark of Intel, Inc. All other trademarks and registered trademarks are the property of their respective owners. Information for Japan Japan Denan statement The following applies to server models 1005r, 703t, and 1002rp: Warning Please be aware of the following while installing the equipment: Please use the connecting cables, power cord, and AC adaptors shipped with t
Inhaltszusammenfassung zur Seite Nr. 5
October 2006 があります。この場合には使用者が適切な対策を取るように要求されることがあ ります。 This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may occur, in which case, the user may be required to take corrective action. 1002rp Server Hardware Installation 5
Inhaltszusammenfassung zur Seite Nr. 6
Standard 1.07 6 CallPilot
Inhaltszusammenfassung zur Seite Nr. 7
Publication history October 2006 CallPilot 4.0, Standard 1.07 of CallPilot Installation and Configuration, 1002rp Server Hardware Installation is issued for general release. September 2006 CallPilot 4.0, Standard 1.06 of CallPilot Installation and Configuration, 1002rp Server Hardware Installation is up-issued. February 2006 CallPilot 4.0, Standard 1.05 of CallPilot Installation and Configuration, 1002rp Server Hardware Installation is issued for general release. January 2006 CallPilot 4.
Inhaltszusammenfassung zur Seite Nr. 8
Publication history Standard 1.07 October 2002 Standard 1.0 of CallPilot Installation and Configuration, 1002rp Server Hardware Installation is issued for general release. 8 CallPilot
Inhaltszusammenfassung zur Seite Nr. 9
Task List To unpack the equipment................................................................ 37 To remove the front bezel ............................................................... 40 To remove the server cover ............................................................ 41 To inspect the server interior........................................................... 42 To replace the front bezel after installation is complete .................. 44 To install the power supply module........
Inhaltszusammenfassung zur Seite Nr. 10
Task List Standard 1.07 10 CallPilot
Inhaltszusammenfassung zur Seite Nr. 11
Contents 1 How to get Help 13 2 1002rp server description 15 Server features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Slot assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Network connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Supported peripheral devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 3 Preparin
Inhaltszusammenfassung zur Seite Nr. 12
Contents Standard 1.07 A EMC emission level protection for the 1002rp Server 79 Index 81
Inhaltszusammenfassung zur Seite Nr. 13
Chapter 1 How to get Help This section explains how to get help for Nortel products and services. Getting Help from the Nortel Web site The best way to get technical support for Nortel products is from the Nortel Technical Support Web site: http://www.nortel.com/support This site provides quick access to software, documentation, bulletins, and tools to address issues with Nortel products. More specifically, the site enables you to: download software, documentation, and product bulletins sea
Inhaltszusammenfassung zur Seite Nr. 14
How to get Help Standard 1.07 Outside North America, go to the following Web site to obtain the phone number for your region: http://www.nortel.com/callus Getting Help from a specialist by using an Express Routing Code To access some Nortel Technical Solutions Centers, you can use an Express Routing Code (ERC) to quickly route your call to a specialist in your Nortel product or service. To locate the ERC for your product or service, go to: http://www.nortel.com/erc Getting Help through a No
Inhaltszusammenfassung zur Seite Nr. 15
Chapter 2 1002rp server description In this chapter Server features 16 Slot assignments 21 Network connectivity 25 Network connectivity 25 Supported peripheral devices 30 Reference documents 31 1002rp Server Hardware Installation 15
Inhaltszusammenfassung zur Seite Nr. 16
1002rp server description Standard 1.07 Server features Introduction This section provides a general overview of the 1002rp server. Server dimensions and weight Height 320 mm (12.5 in.) Width 483 mm (19 in.) Depth (distance from front to back) without front bezel 495 mm (19.5 in.) with front bezel 533 mm (21 in.) Weight of fully loaded system 45.5 kg (100 lb) 16 CallPilot
Inhaltszusammenfassung zur Seite Nr. 17
October 2006 1002rp server description Environmental specifications Environmental condition Specification Operating temperature 10°C to 35°C (50°F to 95°F) Maximum rate of change must not exceed 10°C (50°F) per hour. Non-operating (storage) -40°C to 70°C (-40°F to 158°F) temperature Non-operating humidity 95%, non-condensing at 30°C (86°F) Altitude 1829 m (6000 ft) Electrostatic discharge 15 kV or more Acoustic noise 50 dBA in a typical office ambient temperature (18°C to 25°C [64.4°F to 77°F
Inhaltszusammenfassung zur Seite Nr. 18
1002rp server description Standard 1.07 Front panel features (front view without the front bezel) The front view of the 1002rp server chassis shows redundant dual fans to the left and the right of the status panel. The left drive bay holds six SCSI hard drives with hot-pluggable carriers. The media drive bay, located to the right, houses the CD-ROM, tape drive, and floppy disk drive. Hot-swap fan modules Status panel Hot-swap Tape CD-ROM Floppy hard disk drives drive drive disk drive G1017
Inhaltszusammenfassung zur Seite Nr. 19
October 2006 1002rp server description Rear panel diagram The following diagram shows the slot locations in the rear panel, and the power switch and power input for an AC server. The rest of the diagram is the same for AC or DC servers. SBC card Slot 20 (slot 8) Slot 1 SBC card Power switch PS/2 Keyboard/ Mouse Power input Parallel port Monitor connector ELAN COM2 connector COM1 CLAN connector G101648 1002rp Server Hardware Installation 19
Inhaltszusammenfassung zur Seite Nr. 20
1002rp server description Standard 1.07 Overhead view of empty server showing PCI and ISA connectors The following diagram shows the location of the PCI, SBC, and ISA connectors inside the server. The view in the diagram is from the rear of the server. For slot assignments, see “Slot assignments” on page 21. You must be able to identify slot locations for later steps in the CallPilot installation. PCI SBC ISA connectors connector connectors G101740 20 CallPilot