Inhaltszusammenfassung zur Seite Nr. 1
YY-W2xx
Pedestal Server Chassis
YY-R5xx
5U Rackmount Server Chassis
Installation Guide
2005.04. Version B
1
ZZ17-W2001-B
Inhaltszusammenfassung zur Seite Nr. 2
INDEX 1. Introduction 2. Hardware Packing List 3. System Installation 3.1.Chassis Open 3.2.Motherboard Installation 3.3.Add-on Card Installation 3.4.CD–ROM Drive/FDD Installation. 3.5.Fixed HDD Cage , HDD Installation 3.6.Instructions for Switches and LED Indicators on front panel 3.7.Instructions for cooling fan assembly 3.8.Rack Mount Sliding Rails Installation 4.1 System Assembly 4. Introduction of IDE/SCSI/SATA multi-bay backplane modules 5. How to change versatile as Rackmoun
Inhaltszusammenfassung zur Seite Nr. 3
1. INTRODUCTION YY-W2 series Server Chassis is designed in compliant with EEB3.0 specification (refer to www.ssiforum.org) and ATXV2.1 (refer to www.formfactors.org) Mother Board: YY-W2 is designed for extended ATX (12"x13"), in compliant with ATX spec, CEB and EEB3.0 spec. Storage: The chassis supply drive bays with flexible configuration: A type : Supply 8 x 5.25" + 2 x 3.5” HDD drive bays B type: Supply 5 x 5.25"drive bays and 7 x 3.5" HDD drive bays, i.e. A type plus HDD fi
Inhaltszusammenfassung zur Seite Nr. 4
Thermal Solution: One(1) 120x120mm Cooling Fan is installed, rear mounted Options of two (2) 60*60*25mm, rear mounted. Switches and LED Indicators on front panel Power Switch (Push Switch) Reset Button (Push Switch) Power On LED (Green) HDD LED (Orange flash) FAN ALARM (Red) LAN LED (Green/Flash) X 2 Power Fail LED [optional /reserved for Power Failure Signal] USB Ports X 4, Audio ports [Optional] Rack Mount Rail: (Optional) 24Inch Sliding Rails Chassis Dimensions & Weig
Inhaltszusammenfassung zur Seite Nr. 5
2. Hardware Packing List When you unpack your YY-W2 Server Chassis, check that all the items that you ordered are present in good condition. Review the inventory checklist below to be sure that the components and optional components that you ordered are included. If anything is missing or damage, contact your retailer as soon as possible. Don’t use any uncertified material or components in this system. Chassis A type B type C type ATA IDE SCSI SATA Raid Module Power Supply (O
Inhaltszusammenfassung zur Seite Nr. 6
3. System Installation 3.1 Chassis Open To release two (2) screws on the rear side of chassis, pull the side cover with handle. 3.2 Motherboard Installation Check mounting holes of motherboard, to screw the standoffs required to chassis. Put the Motherboard into the chassis, than screw in for fixing. Next step is to plug the DC ATX-20(or EPS-24) pin connector on the Power Supply to Motherboard and insert the power switch connector properly. Finally, plug the IDE cable connector to
Inhaltszusammenfassung zur Seite Nr. 7
3.3 PCI Add-on Card Installation Remove the tail gate bracket, install PCI card into motherboard, and screw in bracket to rear window of chassis. The chassis could be optional required A Card Clamp Holder which is used to clamp the Add-on Card for avoiding any popping issue. To remove The Clamp Holder first, install Add-on Cards as usual; adjust the holder's height for clamping well the Add-on Cards. 3.4 CDROM/HDD Installation - YY-W2 Server Chassis is designed to install drive
Inhaltszusammenfassung zur Seite Nr. 8
To remove the front panel fist, the front panel is snap in chassis with hocks (or/and screw on by 4pcs screws), please screw off the screws and pull the front panel forward. To remove the metal covers (vented panel). Screw a pair of rails to drive. Slide in the drive install chassis. Screw in two (2) 6#32 on the front plate. 3.5 Hard Disk Drive Installation -How to use Fixed HDD Cage YY-W2 Server Chassis is optional could be built with HDD cage for 5-devices HDD, and the cage
Inhaltszusammenfassung zur Seite Nr. 9
To screw off four (4) screws in the front plate of chassis, the HDD cage could be removed from chassis, install HDD into cage. The cooling fan of HDD cage could be easy swap, release two thumb screws in the front of HDD cage, lift off the fan holder, swap fan and assembly again into cage. How to use HDD brackets YY-W2 Server Chassis is built in two sets of HDD mounting bracket for 2-devices HDD assembly at side of 5.25” drive bay; mounting brackets are packed into the accessory bo
Inhaltszusammenfassung zur Seite Nr. 10
3.6 Instructions for Switches and LED Indicators on front panel The switches and led indicators on front panel have the functions as following: POWER SW: Push Switch, The system power on/off, connects to M/B. Reset SW: Push switch, connect to M/B POWR LED: The system power LED (green), connect to M/B. POWER FAILURE LED: Reserved and optional requested, it may connected with the Power TTL signal wire supplied by PSU RED: The power module is in abnormal operation
Inhaltszusammenfassung zur Seite Nr. 11
Optional Intrusion Switch The chassis could be built with intrusion switch, assembly in left side of chassis, when side cover removed the system will alarm for intrusion, if connected. 3.7. Instructions for cooling fan assembly The chassis could be mounted optional two 60x60 cooling fans in rear mounted for strengthen the air flow by pass of Add-on Cards. 3.8 Rack Mount Sliding Rails Installation YY-W2 needs to use 24” rails (optional). Screw the rails to both sides of the chassis by t
Inhaltszusammenfassung zur Seite Nr. 12
3.9 System Assembly When above steps are done, properly connect all accessories to the system. Then the user can start to install the O/S and required software to the system according to the instruction on the manual of Motherboard. 4. Introduction of IDE/SCSI/SATA multi-bay backplane modules YY-W2 Server Chassis could be optional built with HDD multi-bay backplane raid modules . SI-0357 SI-0347 SI-0237 12 ZZ17-W2001-B
Inhaltszusammenfassung zur Seite Nr. 13
Type A+ SI-0357 x 1 Type A+ SI-0237 x 2 5. How to change versatile as Rackmount Chassis (5U) 1. To remove top cover and bottom cover of chassis. 2. Screw in rack bracket and handles 13 ZZ17-W2001-B
Inhaltszusammenfassung zur Seite Nr. 14
3. Slide into EIA cabinet 14 ZZ17-W2001-B