A detailed guide to the FortiGate-5050 chassis. This FortiGate-5050-R Chassis Guide describes FortiGate-5050
hardware features, and how to install the FortiGate-5050 chassis.
The most recent versions of t
Inhaltszusammenfassung zur Seite Nr. 2
Warnings and cautions Warnings and cautions Only trained and qualified personnel should be allowed to install or maintain FortiGate-5000 series equipment. Read and comply with all warnings, cautions and notices in this document. CAUTION: Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions. Caution: You should be aware of the following cautions and warnings before installing FortiGate-5000 series hardware • Turning off all pow
Inhaltszusammenfassung zur Seite Nr. 3
Contents Contents Warnings and cautions................................................................................................... 2 FortiGate-5050 chassis............................................................................ 5 FortiGate-5050 front panel ............................................................................................. 6 FortiGate-5050 back panel ............................................................................................. 7 Physical des
Inhaltszusammenfassung zur Seite Nr. 4
Contents FortiGate-5050-R Chassis Guide 4 01-30000-87717-20090108 http://docs.fortinet.com/ • Feedback
Inhaltszusammenfassung zur Seite Nr. 5
FortiGate-5050 chassis FortiGate-5050 chassis You can install up to five FortiGate-5000 series boards in the five slots of the FortiGate-5050 ATCA chassis. The FortiGate-5050 is a 5U 19-inch rackmount ATCA chassis that contains two redundant DC power connections that connect to -48 VDC Data Center DC power. The FortiGate-5050 chassis also includes a hot swappable cooling fan tray. If all five slots contain FortiGate-5005FA2, FortiGate-5001SX, or FortiGate-5001FA2 boards, the FortiGate-5050
Inhaltszusammenfassung zur Seite Nr. 6
FortiGate-5050 front panel FortiGate-5050 chassis FortiGate-5050 front panel Figure 1 shows the front of a FortiGate-5050 chassis. Two FortiSwitch-5003 boards are installed in slots 1 and 2. Three FortiGate-5001SX boards are installed in slots 3, 4, and 5. The FortiGate-5050 primary and secondary Shelf Managers and the Shelf Alarm Panel (SAP) are also visible. The factory installed shelf alarm panel displays alarms, provides a telco alarm interface, and also provides serial connections to th
Inhaltszusammenfassung zur Seite Nr. 7
FortiGate-5050 chassis FortiGate-5050 back panel FortiGate-5050 back panel Figure 2 shows the back of a FortiGate-5050 chassis. The FortiGate-5050 chassis back panel includes two redundant -48V to - 58V DC power input connectors labelled Input A and Input B. The power input connectors provide redundant DC power connections for the FortiGate-5050 chassis and distribute DC power to the fan tray and the FortiGate-5000 series boards installed in the FortiGate-5050 chassis. Each power input conne
Inhaltszusammenfassung zur Seite Nr. 8
Physical description of the FortiGate-5050 chassis FortiGate-5050 chassis Physical description of the FortiGate-5050 chassis The FortiGate-5050 chassis is a 5U chassis that can be installed in a standard 19-inch rack. Table 1 describes the physical characteristics of the FortiGate-5050 chassis. Table 1: FortiGate-5050 chassis physical description Dimensions 8.75 x 17 x 15.5 in. (13.3 x 43.2 x 39.4 cm) (H x W x D) Shipping weight 26.75 lb. (12.1 kg) completely assembled with packaging Operating
Inhaltszusammenfassung zur Seite Nr. 9
FortiGate-5050 chassis FortiGate-5050 shelf alarm panel Figure 3: FortiGate-5050 shelf manager front panel Reset Hot Swap ETH 0 and 1 network activity LEDs Button LED 5000SM 10/100 link/Act 10/100 link/Act Retention ETH0 Status Handle Screw 100base-T LEDs Ethernet Table 2: FortiGate-5050 shelf manager LEDs LED State Description ETH 0 10/100 Yellow The Ethernet interface is connected at 100 Mbps. ETH 1 link/Act Green Blinking LED indicates network traffic. Off No link. STATUS Green This shelf man
Inhaltszusammenfassung zur Seite Nr. 10
FortiGate-5050 shelf alarm panel FortiGate-5050 chassis Figure 4: FortiGate-5050 shelf alarm panel front panel Minor Alarm (MIN) (Amber) User 3 Alarm (Amber) Major Alarm (MAJ) (Red) User 2 Alarm (Amber) Critical Alarm (CRT) (Red) User 1 Alarm (Amber) 5050SAP SERIAL SERIAL 1 2 Alarm Retention Telco Alarm Retention LED Reset Screw Interface Screw Button SERIAL 1 (Primary SERIAL 2 (Secondary Shelf Manager) Shelf Manager) Table 3: FortiGate-5050 shelf alarm panel LEDs LED State Description CRT Off N
Inhaltszusammenfassung zur Seite Nr. 11
FortiGate-5050 chassis FortiGate-5050 shelf alarm panel Figure 5: Connections between the shelf managers and the shelf alarm panel 5050SAP SERIAL SERIAL 1 2 Buffer Buffer I²C-Switch I²C-Switch PCA9545 PCA9545 LTC4300 LTC4300 ShMM-500 ShMM-500 Secondary Shelf Manager (Left) Primary Shelf Manager (Right) Shelf alarm panel telco alarms The shelf alarm panel telco alarm interface relay circuits are capable of carrying 60 VDC or 1 A with a max. rating of 30 VA. The shelf alarm panel accepts timed pu
Inhaltszusammenfassung zur Seite Nr. 12
Shelf manager command line interface (CLI) FortiGate-5050 chassis Table 5: Telco alarm connector pin assignment Pin Name Description 1 AMIR+ MinorReset+ 2 AMIR- MinorReset- 3 AMAR+ MajorReset+ 4 AMAR- MajorReset- 5 ACNO CriticalAlarm - NO 6 ACNC CriticalAlarm - NC 7 ACCOM CriticalAlarm - COM 8 AMINO MinorAlarm -NO 9 AMINC MinorAlarm - NC 10 AMINCOM MinorAlarm - COM 11 AMANO MajorAlarm - NO 12 AMANC MajorAlarm - NC 13 AMACOM MajorAlarm - COM 14 APRCO PwrAlarm - NO 15 APRCOM PwrAlarm - COM Shield
Inhaltszusammenfassung zur Seite Nr. 13
FortiGate-5050 chassis Shelf manager command line interface (CLI) Figure 7: Connecting to a shelf manager serial port FortiGate-5050 Shelf Alarm Panel 5050SAP SERIAL SERIAL 1 2 SERIAL1 (Primary SERIAL2 (Secondary Shelf Manager) Shelf Manager) Fortinet RJ-45 to 9-pin Console Cable To PC RS-232 Console Port To connect to the shelf manager CLI using a shelf alarm panel serial port 1 Connect the Fortinet console cable to the shelf alarm panel Serial 1 or Serial 2 port (see Figure 7). 2 Connect the
Inhaltszusammenfassung zur Seite Nr. 14
Shelf manager command line interface (CLI) FortiGate-5050 chassis 2 Enter and confirm a new password for the root account. The password should be between 5 and 8 characters long and should include a combination of upper and lower case letters and numbers. You can use the passwd command to change the root account password at any time. You can also use the passwd command to remove the root account. Enter the passwd command and when prompted for a password, press enter to add a blank password. To
Inhaltszusammenfassung zur Seite Nr. 15
Power connection and configuration Power connection and configuration This chapter describes how to connect data center DC power to a FortiGate-5050 chassis. If data center DC power is not available, this document also describes how to use the FortiGate-5053 power converter tray to supply DC power to the FortiGate-5050 chassis. This chapter describes: • About data center DC power • Connecting the FortiGate-5050 chassis to data center DC power and data center ground • Connecting the FortiGate-
Inhaltszusammenfassung zur Seite Nr. 16
Connecting the FortiGate-5050 chassis to data center DC power and data center ground Figure 8: Connecting a FortiGate-5050 power input connector to data center DC power Data Center -48VDC Data Center connector RTN connector RTN (positive) -48V red to Data (-DC in) black to Center RTN Data Center -48VDC INPUT A -48V RTN (-DC IN) 24 AMP Power wire fixture -48 (-DC in) Positive (black) (RTN) (red) To connect a FortiGate-5050 power input connector to data cente
Inhaltszusammenfassung zur Seite Nr. 17
Power connection and configuration Connecting the FortiGate-5050 chassis to data center ground The FortiGate-5050 chassis has a ground connections on the lower left side of the FortiGate-5050 back panel (see Figure 2 on page 7). This connector must be connected to data center ground. To connect the FortiGate-5050 chassis to data center ground You need the following tools and equipment to connect the FortiGate-5050 chassis to ground: • A number 2 Phillips screwdriver. • An electrostatic discha
Inhaltszusammenfassung zur Seite Nr. 18
Connecting the FortiGate-5050 chassis to AC power using the FortiGate-5053 power converter tray FortiGate-5053 power converter tray front and back panel The front panel of the FortiGate-5053 power converter tray (shown in Figure 10) provides access to the FortiGate-5020/5050 power supplies. Figure 10: Front panel of the FortiGate-5053 power converter tray with one power supply removed AC Power LED DC Power LED Slot 3 Slot 2 Slot 1 The LEDs for each installed power supply are visible from the F
Inhaltszusammenfassung zur Seite Nr. 19
Power connection and configuration The back panel also includes three AC power connectors numbered 1, 2, 3. The AC connector numbering corresponds to the slot numbering showing in Figure 10. Each connector connects AC power directly to a FortiGate-5020/5050 power supply. The FortiGate-5053 can contain 1, 2, or 3 FortiGate-5020/5050 power supplies depending on your requirements. You should only connect AC power to the power supplies that are installed. AC input power characteristics: • AC in
Inhaltszusammenfassung zur Seite Nr. 20
Connecting the FortiGate-5050 chassis to AC power using the FortiGate-5053 power converter tray Figure 12: Non-redundant power for all FortiGate-5050 chassis slots 1 FortiGate-5053 power convertor tray Slot 3 Slot 2 Slot 1 2 FortiGate-5020/5050 power supplies 2 x 800W = 1600W USB 1 2 3 4 5 6 7 8 CONSOLE 5 STA IPM PWR ACC CONSOLE USB 1 2 3 4 5 6 7 8 4 PWR ACC STA IPM USB 1 2 3 4 5 6 7 8 CONSOLE 3 PWR ACC STA IPM 1 FortiGate-5050 2 POWER chassis 1 5000SM 5000SM SMC 10/100 5050SAP 10/100 SMC link/A