Inhaltszusammenfassung zur Seite Nr. 1
61200373L1-5B
Issue 2, August 2001
CLEI Code: SIUXJKEBAA
TM
Total Access 850 Bank Controller Unit Installation and Operation
•
Contents
1. GENERAL ..................................................................... 1
2. INSTALLATION/OPERATION................................ 1
3. OPTIONS....................................................................... 2
4. TESTING........................................................................ 3
5. SPECIFICATIONS...................................
Inhaltszusammenfassung zur Seite Nr. 2
The TA 850 BCU plugs directly into the controller slot Windows Hyperterminal. Windows Hyperterminal in the common module area of the TA 850 chassis. To can be used as a VT 100 terminal emulation program. insert, hold the unit by the faceplate while supporting Open Hyperterminal by selecting PROGRAMS / AC- the bottom side. Align the card edges to the guide CESSORIES / HYPERTERMINAL. Refer to the Help grooves for the designated slot. Insert into the chassis section of Hyperterminal for addition
Inhaltszusammenfassung zur Seite Nr. 3
Figure 2 on page 3 displays where the bantam jacks monitor the T1. Access Maximum Number of DS0s that can Module be used per module Faceplate TEST connector FXS 4 The faceplate DB-9 female TEST connector provides the FXO 4 necessary clock output required by standard DSO Logic *OCU-DP 1 Test equipment such as a TPI 108/109 test set. Specifi- *DSO-DP 1 cally, the TEST connector outputs 8 kHz and 64 kHz *U-BRITE 1 clock reference signal. Figure 3 on page 5 illustrates the *E&M 1 DB-9 TEST con
Inhaltszusammenfassung zur Seite Nr. 4
Table 3. DIP Switch S1 Options Switch Function Description S1-1 Framing Format Enables either Extended Superframe Format (ESF) or Superframe Format (SF). This option must be configured identically with all other T1 network equipment on this circuit. On* SF Off ESF S1-2 Line Code Enables Bipolar Eight-Zero Substitution (B8ZS), which allows for Clear Format Channel operation for the T1 carrier system, or enables Alternate Mark Inversion (AMI). This option must be configured identically with a
Inhaltszusammenfassung zur Seite Nr. 5
6. MAINTENANCE The TA 850 BCU does not require routine maintenance 1 +5 V 6 for design operation. 2 GND 7 TEST 3 64 kHz ADTRAN does not recommend that repairs be attempt- 8 4 8 kHz ed in the field. Repair services are obtained by returning 9 5 the defective unit to ADTRAN Customer Service de- partment. Figure 3. DB-9 Connector Pinout Flash Upload The TA 850 BCU can flash upload firmware to the unit DS0 test equipment is used to test DS0 access modules using the front panel VT 100 craft int
Inhaltszusammenfassung zur Seite Nr. 6
Product Support Information This warranty applies only to the original purchaser and is not transferable without ADTRAN's express written Pre-Sales Inquiries and Applications Support. permission. This warranty becomes null and void if Cus- Please contact your local distributor, ADTRAN Appli- tomer modifies or alters the equipment in any way, other cations Engineering, or ADTRAN Sales: than as specifically authorized by ADTRAN. EXCEPT FOR THE LIMITED WARRANTY DESCRIBED Applications Engineer
Inhaltszusammenfassung zur Seite Nr. 7
Affidavit for Connection of Customer Premises ( ) D. In lieu of the preceding training requirements, Equipment to 1.544 Mbps and/or Subrate Digital the operator(s)/maintainer(s) is (are) under the Services control of a supervisor trained in accordance with _________ (circle one) above. For the work to be performed in the certified territory of ________________________(telco name) I agree to provide ______________________ (telco’s name) with proper documentation to demonstrate com- State of
Inhaltszusammenfassung zur Seite Nr. 8
FCC regulations require that the following For a T1 Port: information be provided in this manual to the customer: Service Type REN/ FIC USOC SOC 1. This equipment complies with Part 68 of the FCC 1.544 Mbps - SF 6.0N 04DU9-BN RJ-48C rules. The required label is affixed to the bottom of the chassis. 1.544 Mbps - SF and 6.0N 04DU9-DN RJ-48C B8ZS 2. An FCC-compliant telephone cord and modular plug is provided with this equipment. This equipment is 1.544 Mbps - ESF 6.0N 04DU9-1KN RJ-48C designe
Inhaltszusammenfassung zur Seite Nr. 9
Canadian Equipment Limitations NOTE The Industry Canada Certification label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department of Commerce does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications compa
Inhaltszusammenfassung zur Seite Nr. 10
10 Issue 2, August 2001 61200373L1-5B