Inhaltszusammenfassung zur Seite Nr. 1
™
6505 212 Combo
Tube Guitar Amplifier Owner's Manual
For information on other great Peavey products, go to your local Peavey dealer or visit us online at www.peavey.com
Inhaltszusammenfassung zur Seite Nr. 2
Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. CAUTION: Risk of electrical shock — DO NOT OPEN! CAUTION: To reduce the risk of electric shock, do not remove cover. No user serviceable parts insi
Inhaltszusammenfassung zur Seite Nr. 3
IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electrical products, basic cautions should always be followed, including the following: 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with a dry cloth. 7. Do not block any of the ventilation openings. Install in accordance with manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers
Inhaltszusammenfassung zur Seite Nr. 4
WICHTIGE SICHERHEITSHINWEISE ACHTUNG: Beim Einsatz von Elektrogeräten müssen u.a. grundlegende Vorsichtsmaßnahmen befolgt werden: 1. Lesen Sie sich diese Anweisungen durch. 2. Bewahren Sie diese Anweisungen auf. 3. Beachten Sie alle Warnungen. 4. Befolgen Sie alle Anweisungen. 5. Setzen Sie dieses Gerät nicht in der Nähe von Wasser ein. 6. Reinigen Sie es nur mit einem trockenen Tuch. 7. Blockieren Sie keine der Lüftungsöffnungen. Führen Sie die Installation gemäß den Anweisungen des Herstelle
Inhaltszusammenfassung zur Seite Nr. 5
INSTRUCTIONS IMPORTANTES DE SECURITE ATTENTION: L’utilisation de tout appareil électrique doit être soumise aux precautions d’usage incluant: 1. Lire ces instructions. 2. Gardez ce manuel pour de futures références. 3. Prétez attention aux messages de précautions de ce manuel. 4. Suivez ces instructions. 5. N’utilisez pas cette unité proche de plans d’eau. 6. N’utilisez qu’un tissu sec pour le nettoyage de votre unité. 7. N’obstruez pas les systèmes de refroidissement de votre unité et instal
Inhaltszusammenfassung zur Seite Nr. 6
INSTRUCCIONES IMPORTANTES PARA SU SEGURIDAD CUIDADO: Cuando use productos electrónicos, debe tomar precauciones básicas, incluyendo las siguientes: 1. Lea estas instrucciones. 2. Guarde estas instrucciones. 3. Haga caso de todos los consejos. 4. Siga todas las instrucciones. 5. No usar este aparato cerca del agua. 6. Limpiar solamente con una tela seca. 7. No bloquear ninguna de las salidas de ventilación. Instalar de acuerdo a las instrucciones del fabricante. 8. No instalar cerca de ninguna fu
Inhaltszusammenfassung zur Seite Nr. 7
ENGLISH ™ 6505 212 combo Tube Guitar Amplifier Congratulations on your purchase of Peavey's 6505 212 combo. Based on the 6505 Stack, this combo offers the same classic sound in a smaller package. The sonic trademark of traditional combo amps is the characteristic dispersion of sound resulting from open-backed cabinetry. It’s one of the features that allows small combos to sound so big— the speakers actually spread the sound around more of the stage. But while open-cabinet designs are efficie
Inhaltszusammenfassung zur Seite Nr. 8
U F E S Top Panel 1 5 6 2 3 4 7 11 12 Inputs (1, 2) The 6505 212’s input block features HIGH [1] and LOW [2] GAIN Inputs. The HIGH GAIN Input has twice the gain of the LOW GAIN Input and should be used when maximum overdrive is desired. When both inputs are used simultaneously, the 6505 212 automatically switches to the normal gain mode (6 dB pad). Situations where both inputs are used simultaneously (alternating between two guitars on stage using both inputs, etc.) should be avoided if pea
Inhaltszusammenfassung zur Seite Nr. 9
U F E S Top Panel 8 9 10 16 13 15 17 14 Equalization (8, 9, 10) The 6505 212’s equalization block features passive LOW, MID and HIGH EQ that is custom tailored to the 6505 sound. Resonance & Presence (13, 14) Unique to the 6505, the RESONANCE [13] control can be set to boost the gain of the power amp in the low frequencies at the resonance/attenuation point of the speaker cabinet. In simple terms, the RESONANCE control works like a low EQ to offset low-end frequency drop-out. The PRESENCE
Inhaltszusammenfassung zur Seite Nr. 10
Rear Panel 19 22 18 20 21 Ground Switch (18) This three-position, rocker-type switch should be operated in the center (zero) position for most applications. If hum or noise is noticed coming from the speaker enclosure(s) with the ground switch in the center position, place the ground switch to positive or negative (+ or -) to minimize hum. Should a hum/noise problem continue, consult your authorized Peavey Dealer, the Peavey factory or a qualified service technician. NOTE: The ground switch
Inhaltszusammenfassung zur Seite Nr. 11
Speaker Connection When connecting the amplifier to the speaker enclosure, make sure to set the impedance selector switch on the rear of the unit to the impedance that matches your enclosure. When two enclosures of equal impedance are used, set the switch to one half the impedance of one enclosure (e.g. for two 16 ohm enclosures, set switch to 8 ohms; for two 8 ohm enclosures, set switch to 4 ohms). The 6505 212 is designed to operate into a minimum of 4 ohms. 11
Inhaltszusammenfassung zur Seite Nr. 12
™ 6505 212 Combo Tube Guitar Amplifier SPECIFICATIONS Power Amplifier Section: Rated Power and Load: 60 W RMS into 16, 8 ohms Power @ Clipping: (Typically @ 5% THD, 1 kHz, 120 V AC line) 65 W RMS into 16, 8 ohms Frequency Response: +0, -3 dB, 50 Hz to 20 kHz, @ 50 W RMS into 8 ohms Hum & Noise: Greater than 74 dB below rated power Power Amp EQ: Active Presence: +10 dB @ 2 kHz Active Resonance: + 10 dB @ cabinet resonant frequency Power Consumption: 200 watts 50/
Inhaltszusammenfassung zur Seite Nr. 13
™ 6505 212 Combo Tube Guitar Amplifier SPECIFICATIONS Preamp Low Gain Input: (-6 dB pad) Impedance: High-Z, 44K ohms All levels are increased by +6 dB Effects Send: Load Impedance: 47K ohms or greater Nominal Output: -10 dBV, 300 mV RMS Effects Return: Impedance: Very High-Z, 470K ohms Designed Level: -10 dBV, 300 mV RMS Preamp Output: Load Impedance: 47K ohms or greater Nominal Output: +10 dBV, 3 V RMS Remote Footswitch: Special 2 button unit with LED indicators (supplie
Inhaltszusammenfassung zur Seite Nr. 14
Notes: 14
Inhaltszusammenfassung zur Seite Nr. 15
PEAVEY ELECTRONICS CORPORATION LIMITED WARRANTY Effective Date: July 1, 1998 What This Warranty Covers Your Peavey Warranty covers defects in material and workmanship in Peavey products purchased and serviced in the U.S.A. and Canada. What This Warranty Does Not Cover The Warranty does not cover: (1) damage caused by accident, misuse, abuse, improper installation or operation, rental, product modification or neglect; (2) dam- age occurring during shipment; (3) damage caused by repair or service
Inhaltszusammenfassung zur Seite Nr. 16
Features and specifications subject to change without notice. Peavey Electronics Corporation • 711 A Street • Meridian, MS 39301 (601) 483-5365 • FAX (601) 486-1278 • www.peavey.com 80303146 © 2005