Inhaltszusammenfassung zur Seite Nr. 1
Series 52
52/RX Mixing Console
Installation Guide
© 2009 DHD Deubner Hoffmann Digital GmbH
Version: 1.1.0
Inhaltszusammenfassung zur Seite Nr. 2
Table of Contents Table of Contents 1 1 Terms of Use - Legal Disclaimer About this Book 2 2 4 3 What is new in this version of the manual? 5 4 Environmental Specifications 6 5 Assembling and Wiring the Hardware ................................................................................................................................... 6 1 System Wiring Meaning of the Controller Module LEDs ...................................................................................................
Inhaltszusammenfassung zur Seite Nr. 3
1 Series 52 - 52/RX Mixing Console Installation Guide 1 Terms of Use - Legal Disclaimer Series 52 52/RX Mixing Console Installation Guide © 2009 DHD Deubner Hoffmann Digital GmbH This manual is copyright of DHD. It might be distributed and copied as long as it is copied completely as a whole and this copyright notice is included. No part of this document may be copied or distributed without prior written permission of DHD Deubner Hoffmann Digital GmbH. Windows is a registered trademark of Micros
Inhaltszusammenfassung zur Seite Nr. 4
About this Book 2 2 About this Book This installation guide will provide you a short introduction how to install an 52/RX Mixing Console. The content of this manual is subject to change without notice. DHD recommends to visit the DHD website once in a while to check if there is a newer version of this document available. Note This manual mainly refers to the physical installation of an 52/RX Mixing Console. Please find more information on this device in the 52/RX manual. Please see the RM4200D m
Inhaltszusammenfassung zur Seite Nr. 5
3 Series 52 - 52/RX Mixing Console Installation Guide The Meaning of Advices in the Text Warning The demands and advices in this fields should be followed unconditional, because otherwise hardware and software products, data bases, as well as persons may suffer a loss. Important The demands and advices in this fields should be followed, because these contents are necessary for the proper operation of the DHD systems. Note Recommendations and further information are marked as notes. Sometimes you
Inhaltszusammenfassung zur Seite Nr. 6
What is new in this version of the manual? 4 3 What is new in this version of the manual? All sections that had been added, deleted or changed are listed below. Click on the entries to reach the respective sections directly. Initial version (1.1.0): Chapter / Section State Note All sections. added Information added. Version 1.1.0 - 14.12.2009 Specifications and design are subject to change without notice. The content of this document is for information only. The information presented in this doc
Inhaltszusammenfassung zur Seite Nr. 7
5 Series 52 - 52/RX Mixing Console Installation Guide 4 Environmental Specifications In the following you can find some general advices concerning the environment of an 52/RX. If these values and standards are not adhered, DHD can not assure the proper functionality of the device. Warning Make sure the device has the operating temperature before switching it on. Also, the relative humidity must not be exceeded. Above all, no humidity must condense on or in the device! operating temperature: +5
Inhaltszusammenfassung zur Seite Nr. 8
Assembling and Wiring the Hardware 6 5 Assembling and Wiring the Hardware In the following you can find information on the mechanical assembling and wiring of an 52/RX Mixing Console and how to integrate it into a mixing system. Warning Avoid damaging components by electrostatic discharge (ESD). Before you touch or mount electronical components, make sure you do not carry any electrostatic charges. Earth yourself using a grounded metal object (heater, rack) to divert electrostatic charges immedi
Inhaltszusammenfassung zur Seite Nr. 9
7 Series 52 - 52/RX Mixing Console Installation Guide DSP Frame and Control Desk coupled via ethernet. The Communication Controller RM420-852/853 in the DSP frame is the communication interface between the DSP frame and the connected modules on one side and the ethernet network for configuration and controlling on the other side. You can find three RJ45 connectors and one USB interface on this module. © 2009 DHD Deubner Hoffmann Digital GmbH Specifications and design are subject to change withou
Inhaltszusammenfassung zur Seite Nr. 10
Assembling and Wiring the Hardware 8 Controller modules for the 52/RX. Since the revision RM420-852B/853B, the upper RJ45 connector provides an RS422 interface (not useable as RS232). On previous modules this port has no function. The middle connector of the three jacks is the interface to the controller network. Connect your console(s) to this RJ45 jack. Therefore, connect this port to a PoE switch, as well as all the fader and control modules and TFT displays. All modules of this network own
Inhaltszusammenfassung zur Seite Nr. 11
9 Series 52 - 52/RX Mixing Console Installation Guide Manufacturer Type Allied Telesyn AT-FS713FC/SC 12x RJ45 1x SC http://www.alliedtelesyn.de Allied Telesyn AT-FS708 8x RJ45 http://www.alliedtelesyn.de 5.1.1 Meaning of the Controller Module LEDs The meaning of the LEDs are identical for the RM420-852 and the RM420-853 Communication Controller modules. Meaning of the LEDs of the RM420-852 and the RM420-853 Communication Controller modules. 1. Reserved for future functi
Inhaltszusammenfassung zur Seite Nr. 12
Assembling and Wiring the Hardware 10 5.2 Calculating the Power Consumption The following facts are important for the choice of power supply units for 52/RX Mixing Consoles. · Use two 52-5048 power supply units for larger mixers with redundancy option inside the 52-5081 or 52-5083 power supply frames. The maximum power consumption in total is 200W. · Use two 52-5048 power supply units for several smaller mixers with redundancy option inside the 52-5081 or 52- 5083 power supply frames. The maximu
Inhaltszusammenfassung zur Seite Nr. 13
11 Series 52 - 52/RX Mixing Console Installation Guide Power wiring possibilities of the 52-4080 PoE switch. Please use the following information to calculate the power consumption of your 52/RX Mixing Console. · Calculate with 10W for each TFT display 52-4015A or 52-4017A. · Calculate with 10W for each non-motorized fader module 52-2020A, 52-2020B and 52-2029A. · Calculate with 15W for each motorized fader module 52-2020M and 52-2029M. · Calculate with 15W for each central module 52-2010. Examp
Inhaltszusammenfassung zur Seite Nr. 14
Assembling and Wiring the Hardware 12 5.2.1 Power Consumption Example 1 In this example a 52/RX console with two fader modules and one central module is used. Calculate 10W for each non- motorized fader module 52-2020A and 15W for the central module 52-2010. Consequently, the power consumption of this 52/RX console is about 35W. In this case a 52-4048 desktop power supply (that provides up to 100W) powers the console via a 52-4080 PoE switch. Power consumption example 1. Version 1.1.0 - 14.12.2
Inhaltszusammenfassung zur Seite Nr. 15
13 Series 52 - 52/RX Mixing Console Installation Guide 5.2.2 Power Consumption Example 2 An example of a larger console with motorized faders and a central TFT display can be found in the following. This console includes six motorized fader modules 52-2029M and for each of these modules you need to calculate with 15W. Moreover the central control module 52-2010 has a power consumption of up to 15W and the TFT display 52-4015A has a power input of 10W. In total a power supply is need that provide
Inhaltszusammenfassung zur Seite Nr. 16
Index 14 motorized fader modules 13 Index N non-motorized fader modules 12 5 52-4048 12 O 52-4080 10, 12 52-5048A 13 operating temperature 5 52-5083A 13 52-5088A 13 P A Power Consumption 10, 12, 13 Assembling and Wiring the Hardware 6 R C RJ45 connector 6 RM420-852 9 Controller Module LEDs 9 RM420-852/853 Communication Controller 6 RM420-853 9 E S electrostatic discharge 6 Environmental Specifications 5 System Wiring