Inhaltszusammenfassung zur Seite Nr. 1
6416m
Mic Input Module
RCI
Remote Control Interface
Mic Control Surface
User Guide
P/N 9310 1013 0001F rev. 2.00
© 2009 Aviom, Inc.
Inhaltszusammenfassung zur Seite Nr. 2
Certifications ETL/cETL Listed EMC: EN 55013, EN 55020, SAA AS/NZS 1053 Conforms to: IEC 60065, EN 60065, UL 6500‑ 2001 Certified to: CAN/CSA E60065, KETI RoHS Status: Pb‑ free Pb Pb-Free Notice of Rights All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means—electronic, mechanical, photocopy, recording, or otherwise—without written permission of Aviom, Inc. Trademarks Aviom, A‑Net, the A‑Net icon, Pro16, Pro64, and Virtual Data Cable a
Inhaltszusammenfassung zur Seite Nr. 3
READ THIS FIRST Important Safety Instructions 1. Read these instructions. 2. Keep these instructions 3. Heed all warnings. 4. Follow all instructions. ! 5. Do not use this apparatus near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safe
Inhaltszusammenfassung zur Seite Nr. 4
WARNING! ! ! TO REDUCE THE DANGER OF ELECTRICAL SHOCK DO NOT REMOVE COVERS. NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL ONLY To reduce the risk of fire or electrical shock, do not expose this product to rain or other types of moisture. To avoid the hazard of electrical shock, do not handle the power cord with wet hands. Replace fuse with same type and rating. Operating Temperature: 10˚C to 50˚C (50˚F to 122˚F) Risque de choc électrique – ne pas ouvrir.
Inhaltszusammenfassung zur Seite Nr. 5
Aviom, Inc. Limited Warranty Aviom, Inc. warrants this product against defects in materials and workmanship for a period of one year from the date of the original retail purchase. This warranty does not apply if the equipment has been damaged due to misuse, abuse, accident, or problems with electrical power. The warranty also does not apply if the product has been modified in any way, or if the product serial number has been damaged, modified, or removed. If a defect is discovered, first
Inhaltszusammenfassung zur Seite Nr. 6
Warranty Information Please record the following information for future reference: Your Authorized Aviom Dealer: Name: Address: Phone: Serial Numbers of Your Aviom Products: Date of Purchase: Your Authorized Aviom Dealer is your primary source for service and support. The information recorded above will be helpful in communicating with your Authorized Aviom Dealer should you need to contact Aviom Customer Service. If you have any questions concerning the use of t
Inhaltszusammenfassung zur Seite Nr. 7
Table of Contents Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 The EtherCon Connector . . . . . . . . . . . . . . . . . . . 2 AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 AC Lin
Inhaltszusammenfassung zur Seite Nr. 8
Password Protection . . . . . . . . . . . . . . . . . . . . 27 6416m Front Panel Components. . . . . . . . . . . . . . . . . 29 6416m Rear Panel Components . . . . . . . . . . . . . . . . . 32 6416m Network Settings . . . . . . . . . . . . . . . . . . . . 34 Control Master . . . . . . . . . . . . . . . . . . .
Inhaltszusammenfassung zur Seite Nr. 9
Recall a Preset . . . . . . . . . . . . . . . . . . . . . . . 55 Preset Rules. . . . . . . . . . . . . . . . . . . . . . . . . 55 6416m Rear Panel Features . . . . . . . . . . . . . . . . . . . 56 AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Fuse . . . . . . . . . . . .
Inhaltszusammenfassung zur Seite Nr. 10
No Control Indicator . . . . . . . . . . . . . . . . . . . . 80 Save and Recall Buttons . . . . . . . . . . . . . . . . . . 80 Cancel and Enter Buttons . . . . . . . . . . . . . . . . . . 81 MCS Channel Strip . . . . . . . . . . . . . . . . . . . . . . . . 81 Gain Display . . . . . . . . . . . . . . . .
Inhaltszusammenfassung zur Seite Nr. 11
Dimensions ‑ RCI . . . . . . . . . . . . . . . . . . . . . .116 MCS Specifications. . . . . . . . . . . . . . . . . . . . . . . .118 Dimensions ‑ MCS . . . . . . . . . . . . . . . . . . . . . 119 Mounting the MCS . . . . . . . . . . . . . . . . . . . . .121 GPIO Specifications . . . . . . . . . . . .
Inhaltszusammenfassung zur Seite Nr. 12
Welcome Thank you for purchasing the 6416m Mic Input Module, RCI Remote Control Interface, and MCS Mic Control Surface. All Pro64 products are powered by A‑ Net®, Aviom’s proprietary data transmission protocol designed especially for the unique demands of live streaming audio. In developing the Pro64 Series, we have made every effort to make the user interface as easy to use and understand as possible. This User Guide is designed to familiarize you with the features and functions of your n
Inhaltszusammenfassung zur Seite Nr. 13
RCI Remote Control Interface Features: • Any number of RCI modules can be installed in a Pro64 network • Four Control Groups • Headphone monitor with level control • Rear‑ panel XLR line‑ level output for monitoring selected mic preamp channel • Pad switch for XLR line‑ level output • Backup DC power connector MCS Mic Control Surface Features: • Full real‑ time control of the selected channel’s gain, phase, mute, pad, +48V phantom power, and low cut filter • Real‑ time metering o
Inhaltszusammenfassung zur Seite Nr. 14
AC Power Always plug the unit into a properly grounded (earthed) outlet. Always use the AC line cord that was shipped with the unit. Grasp the power cable by the connector and never by the cord itself when connecting and disconnecting it from the power source. Do not expose the Pro64 device to moisture, rain, or excessively damp environments. AC Line Conditioning Aviom products are digital devices and as such are sensitive to sudden spikes and drops in the AC line voltage. Changes in the
Inhaltszusammenfassung zur Seite Nr. 15
Transporting the 6416m in a Rack The 6416m Mic Input Module has attachment points for rear support hardware built into the product’s sides. If the 6416m is to be rack mounted and transported frequently, be sure to support the rear of the unit with appropriate mounting hardware that matches the size of the rack used to avoid damage to the product. Ventilation The 6416m is convection cooled and does not require a built‑ in fan. Always allow adequate ventilation for devices mounted in equipme
Inhaltszusammenfassung zur Seite Nr. 16
About A-Net Aviom’s A‑ Net® is the only networking technology conceived, designed, and optimized for managing and distributing audio using ordinary Cat‑ 5e cables (or fiber by adding the MH10f Merger Hub). As implemented in the Pro64® Series products, A‑ Net can transmit up to 128 channels of uncompressed 24‑ bit audio with the reliability and fidelity of analog, and the power and flexibility of a true digital network. Pro64 A‑ Net allows variable sample rates in three ranges, from 44.1k
Inhaltszusammenfassung zur Seite Nr. 17
rates, from 44.1/48kHz± to 192kHz±. Because no sample rate converters are used, audio transmission is kept fast and clean, eliminating the audio artifacts and signal degradation inherent to sample rate conversion—even when syncing to an external clock source. Any Pro64 I/O module can be designated the Clock Master for the network, generating and distributing its internal clock. Digital I/O modules are capable of syncing to and distributing an external clock from a Word Clock or AES3 sourc
Inhaltszusammenfassung zur Seite Nr. 18
Support For Pro16 Series Products Pro64 Series products can be combined with Pro16™ Series output products such as the Pro16 Monitor Mixing System by adding the Pro64 ASI A‑ Net Systems Interface. This 1U module converts Pro64 data to Pro16 data, providing up to four streams of 16‑ channel data (depending on the Pro64 sample rate) that can be used with A‑ 16II and A‑ 16R Personal Mixers, A‑ Net Distributors, and AN‑ 16/o Output Modules. The ASI is not compatible with the A‑ Net output of
Inhaltszusammenfassung zur Seite Nr. 19
Firmware Notice All Pro64 devices in a network should be updated to use the most recent firmware version to ensure trouble-free operation. As new Pro64 modules are released, older Pro64 products need to be updated so that they recognize the features and functions of the newer modules—something that is especially important if one of the older devices will be used as the network’s Control Master. (If for some reason you cannot update the firmware on older Pro64 devices before using them, set
Inhaltszusammenfassung zur Seite Nr. 20
Pro64 Interface Conventions Many Pro64 Series products have similar user interface components, including buttons, LEDs, and switches. When describing the features and functions of Pro64 Series products, the following conventions will be used. Cat-5e All Cat‑ 5e connections between A‑ Net devices should use Unshielded Twisted Pair (UTP) cable. The cable can be of the stranded or solid type; solid wire performs better over long distances, while stranded wire is more flexible and easier to m