Inhaltszusammenfassung zur Seite Nr. 1
AV-P2
Output Module
User Guide
P/N 9310 1019 0001F Rev. 1.00
Inhaltszusammenfassung zur Seite Nr. 2
Certifications ETL/cETL Listed EMC: EN 55013, EN 55020, SAA AS/NZS 1053 Conforms to: IEC 60065, EN 60065, UL 6500-2001 Certified to: CAN/CSA E60065, KETI RoHS Status: Pb-free Notice of Rights All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means—electronic, mechanical, photocopy, recording, or otherwise—without written permission of Aviom, Inc. Trademarks Aviom, A-Net, the A-Net icon, Pro16, and Pro64 are trademarks of Aviom, Inc. Al
Inhaltszusammenfassung zur Seite Nr. 3
WARNING! READ THIS FIRST Important Safety Instructions ! NO USER SERVICEABLE PARTS INSIDE 1. Read these instructions. 2. Keep these instructions REFER SERVICING TO QUALIFIED SERVICE PERSONNEL ONLY 3. Heed all warnings. 100-240VAC~ • To reduce the risk of fire or electrical shock, do Conceived,designed,and manufactured by Aviom,Inc. 4. Follow all instructions. 50/60Hz 300W not expose this product to rain or other types of 5. Do not use this apparatus near water. moisture. CAUTION: Replacefu
Inhaltszusammenfassung zur Seite Nr. 4
Aviom, Inc. Limited Warranty Warranty Information Please record the following information for future reference: Aviom, Inc. warrants this product against defects in materials and workmanship for a period of one year from the date of the original retail purchase. Your Authorized Aviom Dealer: This warranty does not apply if the equipment has been damaged due to Name: misuse, abuse, accident, or problems with electrical power. The warranty also does not apply if the product has been modifi
Inhaltszusammenfassung zur Seite Nr. 5
A-Net Expansion . . . . . . . . . . . . . . . . . 23 Table of Contents 32-Channel Examples . . . . . . . . . . . . . . 24 32 Channels Send by Zero Channels Return . . . . 24 16 Channels Send by 16 Channels Return . . . . . 26 Warranty Information��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� vi Adding More Audio Outputs . . . . . . . . . . . . . . 27 Welcome ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ���
Inhaltszusammenfassung zur Seite Nr. 6
x
Inhaltszusammenfassung zur Seite Nr. 7
Welcome Thank you for purchasing the Aviom Pro16™ AV-P2 Output Module. This User Guide is designed to familiarize you with the features of your new Pro16 product and to have you up and running in no time. Features The AV-P2 Output Module is designed to output a 2-channel mono or stereo signal from a Pro16 system. AV-P2 Output Module Features: • Two balanced line-level audio output channels • Individual output levels for each channel • Audio output level DIP switches • Euroblock termina
Inhaltszusammenfassung zur Seite Nr. 8
Front Panel Components Rear Panel Components CHANNEL AV-P2 LEFT RIGHT 1 16 2 MUTE 15 3 14 4 x y z ON 13 5 6 12 STEREO A-NET POWER 11 7 v w 10 8 PAIR ACTIVE OUTPUT LEVELS 9 1. Output Level DIP Switches 2. Audio Mute Switch 3. A-Net Channel Selector 4. Stereo Pair LED 5. A-Net Active LED 6. Power LED 7. Reversible Mounting Flanges AUDIO OUTPUT LEFT RIGHT OUT IN 18-24 VDC v AV-P2 DC POWER 500mA + – + – w x 1. DC Power Connector 2. Audio Output Euroblock Connectors
Inhaltszusammenfassung zur Seite Nr. 9
Compatibility The AV-P2 Output Module can be used with the following Aviom Pro16 products: • AN-16/i Input Module • AN-16/i-M Mic Input Module • AV-M8 Mic Input Module • Aviom16/o-Y1 A-Net card for use with Yamaha® consoles • D-16c A-Net card for use with DiGiCo® consoles • A-16R Personal Mixer • A-16II Personal Mixer • A-16D A-Net Distributor • A-16D Pro A-Net Distributor • AN-16/o Output Module • AN-16SBR System Bridge • A-16T Transmitter (discontinued) • A-16 Personal Mixer (disconti
Inhaltszusammenfassung zur Seite Nr. 10
Pro16 Series Systems A complete Pro16™ Series audio network system consists of at least one Pro16 input module connected to at least one Pro16 output device such as the AV-P2 Output Module, AN-16/o Output Module, or A-16II Personal Mixer. Many configurations are possible by using additional input modules and/or Personal Mixers and output modules. About A-Net Aviom’s A-Net® is a high-speed data transmission protocol. It is capable of sending and receiving uncompressed, high-quality audio
Inhaltszusammenfassung zur Seite Nr. 11
Cables Used With A-Net Devices Pro16 Input Module All Cat-5e connections between A-Net devices should use Unshielded Up to 500 feet Twisted Pair (UTP) cable. The cable can be of the stranded or solid type; of Cat-5e cable solid wire performs better over long distances, while stranded wire is can be used to more flexible and easier to manipulate and therefore easier to work connect with in a performance situation. each system Pro16 Output Modules, component Cables designated as Cat-5
Inhaltszusammenfassung zur Seite Nr. 12
Extending Cable Lengths Mounting the AV-P2 Cat-5e cables can be extended by using a simple passive device called an inline coupler to add length to existing cables (as long as you do not The AV-P2 module is designed to be mounted to any flat surface. exceed the specified maximum cable length). If you need a longer cable Optionally, it can be rack mounted using a standard 19-inch rack shelf. on occasion, this is a simple solution. Note that it is possible that the Two AV-P2 units can fit on a
Inhaltszusammenfassung zur Seite Nr. 13
stereo signal from the Pro16 A-Net stream connected to the AV-P2 via Panel Descriptions its A-Net In port. The Channel Selector provides mono or stereo output signals based on This section explains the basic layout of the front and rear panels of your the settings of the Pro16 network’s input module’s Stereo Link switches. new Aviom product. The diagrams on the previous pages can be used as a quick visual guide to the location of the components of the AV-P2 P Neot : The left and right
Inhaltszusammenfassung zur Seite Nr. 14
AV-P2 Rear Panel The rear panel of the AV-P2 Output Module contains the DC power connector, the left/right audio output Euroblock connections, and the A-Net connections. The outputs on the AV-P2 use 5.0 mm Euroblock connectors, and can be connected to balanced or unbalanced audio devices. Male Euroblock jacks are provided. AUDIO OUTPUT LEFT RIGHT OUT IN 18-24 VDC AV-P2 DC POWER Euroblock connectors plug into the sockets on the AV-P2 panel. 500mA + – + – The Euroblock plugs can be c
Inhaltszusammenfassung zur Seite Nr. 15
Connecting Audio The audio outputs on the AV-P2 Output Module can be connected to balanced or unbalanced devices via the Euroblock jacks. Wiring a Euroblock The Euroblock plug, showing the screws that hold the individual wires in place (left-to-right), hot (+), cold (-), and ground Euroblock connectors provide an easy, solder-free way of making audio connections between the AV-P2 and other audio components. Only a small flat-blade screw driver is required to make connections. For extra s
Inhaltszusammenfassung zur Seite Nr. 16
1. Strip the insulating jacket of the cable back about .75 Setting Output Levels inch (18 mm) to reveal the individual hot and ground Output levels on the AV-P2 are set with the DIP switches on the front wires within. panel. Individual settings are possible for the left and right audio 2. Remove a small amount of each individual wire’s channels. insulation (approximately .25 inch, 6 mm). 3. On the Euroblock plug, use a small screw driver to loosen and open the sockets that will receive t
Inhaltszusammenfassung zur Seite Nr. 17
DIP Switch Settings Table The following table lists the DIP switch settings for the AV-P2 left/right output levels. In the output levels table, “0” indicates the down position and “1” indicates the up position on the DIP switch. DIP Switch Setting LEVEL (dB) 1 2 3 4 5 6 1 1 1 1 1 1 0 1 1 1 1 1 0 -1.2 1 1 1 1 0 1 -2.9 1 1 1 1 0 0 -4.6 0 1 1 1 1 1 -5.7 0 1 1 1 1 0 -6.9 0 1 1 1 0 1 -8.6 0 1 1 1 0 0 -10.3 0 1 0 1 1 1 -12.9 0 1 0 1 1 0 -14.1 0 1 0 1 0 1 -15.8 0 1 0 1 0 0 -17.5 0 0 1 1 1 1 -19.0 0
Inhaltszusammenfassung zur Seite Nr. 18
A-Net Connections When creating a Pro16 A-Net system, the simplest connection method uses what is called a daisy chain. That is, each A-Net device is connected in series. The first device in the chain receives its A-Net signal from the AV-M8 Mic Input Module’s A-Net Out port. Each successive A-Net compatible device gets its A-Net connection from the A-Net Out port of the device preceding it in the daisy chain. There is one drawback to this connection method, however. If one A-Net device i
Inhaltszusammenfassung zur Seite Nr. 19
A-Net Out Audio Networks Pro16 Input A-Net In Pro16 A-Net input and output modules can be combined to create audio A-16D networks of up to 64 audio channels with unlimited expansion. A-Net Out (x8) 8-Channel Systems The most basic A-Net based system uses one input module connected to one output module or Personal Mixer. For example, the AV-M8 can A-Net In be connected to an AV-P2 Output Module to deliver eight discrete line- level audio signals to powered speakers, recording devices, mixers,
Inhaltszusammenfassung zur Seite Nr. 20
32-Channel Systems 16 Channels In Pro16 Input Aviom’s Pro16 audio networking products work in blocks of 16 channels. A-Net, up to 500 feet, 150 meters Audio networks of 32 channels can be configured as: • 32 channels send by zero channels return (32 x 0 ) AN-16/o ...to teleconferencing Up to 16 Channels Out • 16 channels send by 16 channels return (16 x 16) head end • 0 channels send by 32 channels return (0 x 32) AV-P2 2 Channels Out ...to stereo recording device Systems up to 32 audio chan