Inhaltszusammenfassung zur Seite Nr. 1
Siemens ID Mouse V 3.1
User Guide
June 2000 Edition
Copyright © Siemens AG 2000
Inhaltszusammenfassung zur Seite Nr. 2
Publisher: ICM CD IS FT Hofmannstr. 31 81379 Munich
Inhaltszusammenfassung zur Seite Nr. 3
Germany
Inhaltszusammenfassung zur Seite Nr. 4
Siemens ID Mouse V3.1 User Guide Installation and Startup June 2000 Edition Table of Contents 1 Installation and Startup.....................................................................................................6 1.1 System Requirements .....................................................................................................6 1.2 Installation Instructions .....................................................................................................6 1.3 Startup......
Inhaltszusammenfassung zur Seite Nr. 5
User Guide Siemens ID Mouse V3.1 June 2000 Edition Installation and Startup 5.10 Where can I find out which version of ID Mouse I am using? ....................................23 5.11 What can I use the ID Mouse scroll wheel for?..........................................................24 5.12 Frequently Asked Questions?....................................................................................24 6 Safety regulations:......................................................................
Inhaltszusammenfassung zur Seite Nr. 6
Siemens ID Mouse V3.1 User Guide Installation and Startup June 2000 Edition 1 Installation and Startup 1.1 System Requirements • It is assumed that the PC has Windows98 installed on it and is USB-capable. The USB capability of the system can be tested by double-clicking the program Tools\USBREADY.EXE supplied on the CD-ROM. • The Siemens ID Mouse should not be connected before the installation. • The Windows98 operating system CD is required for the installation. • The screen resolution must be
Inhaltszusammenfassung zur Seite Nr. 7
User Guide Siemens ID Mouse V3.1 June 2000 Edition Installation and Startup Following the installation of the Siemens ID Mouse, the screen saver will be installed, but not yet activated. You can set the screen saver via the Display icon in the Control Panel. Please note that password protection must be disabled. The user instructions are supplied as a PDF file on the CD. In order to read this file, you will need the Acrobat Reader program, which can also be installed from the Siemens ID Mouse CD
Inhaltszusammenfassung zur Seite Nr. 8
Siemens ID Mouse V3.1 User Guide Working with the Application June 2000 Edition 2 Working with the Application 2.1 User Manager 2.1.1 Selecting Users In the “Select User” mask, you can choose whether user data or options are to be edited via the corresponding tabs. On starting the User Manager, the “User Data” page is always displayed, since this is most frequently used. 2.1.1.1 User Data Mask Description This mask is used to select a user. User List This list displays the user data in three col
Inhaltszusammenfassung zur Seite Nr. 9
User Guide Siemens ID Mouse V3.1 June 2000 Edition Working with the Application The individual column widths can be increased or decreased as desired by simply pointing to the line between the columns and changing the column width while pressing the mouse button. “New ...” Button Pressing this button opens the “New User Data” mask, which can be used to add a new user to the archive. “Edit ...” Button This button is enabled only if a user has been selected in the user list. If you have selected a
Inhaltszusammenfassung zur Seite Nr. 10
Siemens ID Mouse V3.1 User Guide Working with the Application June 2000 Edition 2.1.1.2 Options Mask Description This mask is used to define the system settings of the Siemens ID Mouse. Timeout in Seconds This field can be used to define how long the image scan by the sensor is to run before the application issues an error. The factory default setting for the Siemens ID Mouse is 10 seconds. F The administrator can set values between 1 and 200. Minimum Length This field can be used to define the
Inhaltszusammenfassung zur Seite Nr. 11
User Guide Siemens ID Mouse V3.1 June 2000 Edition Working with the Application Security Level Three levels of security can be set to define the security level with which the identification is to be performed: High, Medium, Low. These settings have various different consequences for authorized users, with regard to ease of operation, and for the security of the system. "High" increases system security since more fingerprint characteristics are checked. However, this may also cause an increased n
Inhaltszusammenfassung zur Seite Nr. 12
Siemens ID Mouse V3.1 User Guide Working with the Application June 2000 Edition 2.1.2 Adding, Editing and Deleting Fingerprint Data This mask is used to add, delete or improve individual fingerprints and to manage user data. The header line indicates whether the data of an existing user is being edited or whether the addition of a new user is involved. 2.1.2.1 User Data Mask Description Status on adding a new user: All fields are empty, except for the “Group” field, which is preset to the defaul
Inhaltszusammenfassung zur Seite Nr. 13
User Guide Siemens ID Mouse V3.1 June 2000 Edition Working with the Application All fields are filled with the data that was read from the User Manager. The “User ID” field cannot be edited. First Name / Last Name These fields are used to specify the first name and last name of the user, respectively. F A maximum of 40 characters are permitted. F Both fields are mandatory. Group In this field you specify whether the user is an administrator or a normal user of the PC. F Administrators are author
Inhaltszusammenfassung zur Seite Nr. 14
Siemens ID Mouse V3.1 User Guide Working with the Application June 2000 Edition 2.1.2.2 Finger Data Mask Description This mask is used to capture the individual fingerprints of the user. Status on adding a new user: No finger is highlighted in green, and the index finger of the right hand is the default. Status on editing user data: The fingers for which fingerprints have already been stored are identified by a green circle above each finger. No finger is selected (red border). Circles above the
Inhaltszusammenfassung zur Seite Nr. 15
User Guide Siemens ID Mouse V3.1 June 2000 Edition Working with the Application Select Hand / Select Finger These combo boxes are used to select the hand and finger, respectively. On changing the hand or finger, the corresponding circle above the finger is also selected automatically. “Start Capture” Button If the selected finger is already stored in the archive, you will be asked if you want to improve the captured image. If the finger is not yet in the archive, you are requested three times to
Inhaltszusammenfassung zur Seite Nr. 16
Siemens ID Mouse V3.1 User Guide Working with the Application June 2000 Edition 2.2 Logging on 2.2.1 Logging on to the System 2.2.1.1 Logging on to the System with a Fingerprint Mask Description The mask with the Fingerprint tab is used to identify a user via a fingerprint. If the user has been saved in the archive, the mask is closed after about 2 seconds, and the PC can be used. If the user has not yet been stored in the archive, the mask remains open. Fingerprint Image A simple animation requ
Inhaltszusammenfassung zur Seite Nr. 17
User Guide Siemens ID Mouse V3.1 June 2000 Edition Working with the Application If the user is found in the archive, the First Name and Last Name of that user appear. “Repeat Logon” Button If the finger was not placed on the sensor in time or the user is not stored in the archive, or if an error occurs on identification, you can use this button to start the identification process again. “Shut Down” Button If no identification is possible, this button can be used to shut down the PC. 2.2.1.2 Logg
Inhaltszusammenfassung zur Seite Nr. 18
Siemens ID Mouse V3.1 User Guide Working with the Application June 2000 Edition User ID A unique user ID that is stored for each user in the User Manager and required for the logon. Password A password that can be stored for each user in the User Manager. The “Password” field may be left empty if the administrator has permitted the use of blank passwords in the User Manager. “Logon” Button This button can only be selected when the User ID and/or Password fields have been filled. On pressing this
Inhaltszusammenfassung zur Seite Nr. 19
User Guide Siemens ID Mouse V3.1 June 2000 Edition Administration 3 Administration 3.1 Providing Additional Security for the Computer via BIOS Settings Apart from the steps performed to secure the computer after the installation, the administrator should also make use of the security settings available in the BIOS of modern PCs. Almost all modern PCs include options to prevent the computer from being started with a floppy disk or to change the startup sequence so that the computer boots first fr
Inhaltszusammenfassung zur Seite Nr. 20
Siemens ID Mouse V3.1 User Guide Technical Data and Constraints June 2000 Edition 4 Technical Data and Constraints Mouse 3-button mouse with scroll wheel Supported operating systems Windows98 Port USB I/O level USB V1.0 Mouse function: optomechanical Fingerprint acquisition Capacitive scanning Resolution 224x288 pixels 513 dpi; data format: 8 bits/pixel Tracking speed 200 +/- 50 mm/sec Minimum actuations per switch 1 million Power consumption in mouse mode 30 mA Power consumption in scanning mod