Inhaltszusammenfassung zur Seite Nr. 1
SE-2151MA
Battery
15/2/100 Amp
Charger
Automatic Battery Charger
Models:
With Engine Start
Owner's Manual
–Save–
Important Safety Instructions
Read Rules for Safe Operation and Instructions Carefully
Working in vicinity of a lead-acid battery is dangerous. Batteries generate explosive gases during normal
battery operation. For this reason, it is of utmost importance that each time before using your charger, you
read this manual and follow the instructions exactly.
WARNING: Handling the cord on t
Inhaltszusammenfassung zur Seite Nr. 2
B. PERSONAL PRECAUTIONS AND SAFETY 1. WARNING: Wear complete eye protection and clothing necklaces, and watches when working with a lead-acid protection, when working with lead-acid batteries. battery. A lead-acid battery can produce a short-circuit 2. Make sure someone is within range of your voice or close current high enough to weld a ring (or the like) to metal, enough to come to your aid when you work with or near a causing a severe burn. lead-acid battery. 6. Take care not to drop a metal
Inhaltszusammenfassung zur Seite Nr. 3
D. METER AND SWITCH FUNCTIONS BATTERY TYPE: You may select between two basic Battery Types: Regular or Deep Cycle Battery. Both settings operate automatically and will shut off when the battery is fully charged. DC AMPS Use the Regular for all wet-cell, lead-acid batteries. (This charger CHARGING START is not recommended for Gel-Cell and AGM batteries.) Use the Deep Cycle setting for all Deep Cycle wet-cell, lead-acid batter- 0 100 5 10 15 ies. How can you tell your battery type? Deep
Inhaltszusammenfassung zur Seite Nr. 4
E. OPERATING INSTRUCTIONS: CHARGING BATTERY IN VEHICLE When charging battery in the vehicle, take care to determine the battery type and which post is grounded. To reduce risk of a spark near battery, follow these steps when battery is installed in vehicle. WARNING: A spark near battery may cause battery explosion. 1. Position AC power cord and DC charging cords to reduce WARNING: Do not connect clip to carburetor, fuel lines, or sheet- risk of damage by hood, door, or moving engine parts. metal
Inhaltszusammenfassung zur Seite Nr. 5
G. CHARGE PERIOD H. TROUBLESHOOTING The approximate time required to bring a battery to a full charge If a problem does occur, check the following: state depends upon the number of ampere hours (AH’s) de- PROBLEM POSSIBLE CAUSE SOLUTION pleted from the battery. AH’s are determined by multiplying the number of hours times the number of amps supplied by a bat- No meter reading. Clips are not making Rock clips back and tery to a load. For example - if a load was connected to a battery a good connec
Inhaltszusammenfassung zur Seite Nr. 6
MANUAL DEL PROPIETARIO B. PRECAUCIONES Y SEGURIDAD PERSONALES EL TRABAJAR CERCA DE BATERIAS DE PLOMO-ACIDO ES 1. ADVERTENCIA: Al trabajar con baterías de plomo-ácido, use protección PELIGROSO. LAS BATERIAS GENERAN GASES EXPLOSIVOS DU- completa de los ojos y protección de la ropa. RANTE LA OPERACION NORMAL DE LA BATERIA. POR ESTA RAZON 2. Cuando usted trabaje con o esté cerca de una batería de plomo-ácido, ES SUMAMENTE IMPORTANTE QUE LEA ESTE MANUAL Y OBSERVE asegúrese que alguien esté al alcance
Inhaltszusammenfassung zur Seite Nr. 7
batería. Nunca lo conecte a un receptáculo remoto ni a otro dispositivo para MEDIDOR: El medidor indica en amperios la cantidad de corriente que la cargar la batería desde un lugar distante. Los cables podrían ser batería está sacando del cargador. Al nivel de carga de 15 Amperios, una inadecuados para resistir la corriente de este cargador y podrían recalen- batería típicamente descargada puede al principio sacar más de 15 Amperios tarse. A menudo estos cables vienen unidos con otros cable
Inhaltszusammenfassung zur Seite Nr. 8
8. Cuando el acumulador está completamente cargado, desenchufe el calcule aproximadamente un 25% más del tiempo de carga. En nuestro ejemplo, aumente 50 minutos al tiempo de 3 hora y 20 minutos, lo que dará cargador de la toma de corriente alterna. 9. Quite las pinzas en el siguiente orden: (1) del chasis y (2) del terminal del como resultado un tiempo de recarga total de 4 hora y 10 minutos. acumulador. IDENTIFICACIÓN Y SOLUCIÓN DE PROBLEMAS Si ocurre un problema, revise lo siguiente: F.INSTRUC