Inhaltszusammenfassung zur Seite Nr. 1
Installation Instructions / Warranty
Electronic
15100XX1
15101XX1
90576601 07/2005
Inhaltszusammenfassung zur Seite Nr. 2
Electronic Lavatory Faucet with Adjustable Temperature 15100XX1 Electronic Lavatory Faucet 15101XX1 Technical Data Recommended water pressure 14.5 – 116 psi o o Max. incoming hot water temp 120 F – 140 F* Max. flow rate 2.2 gpm Automatic turnoff after 35 sec. Battery Lithium CR-P2/6V Hole size 1 3/16” Max. countertop depth 1 3/4” Installation Considerations • This unit cannot be used with a continuous flow water heater. • Large differences in pressure between the hot and cold water supplies shou
Inhaltszusammenfassung zur Seite Nr. 3
Installation Instructions • Remove the mounting nut, metal washer, and fiber washer from the faucet. • Place the faucet with sealing gasket on top of the sink.(1) • From beneath the sink, install the fiber washer, metal washer, and mounting nut (2). • Install the adapters to the hot and cold stops (3). Attach the check valves and filter screens to the adapters (4). Attach the hoses to the check valves (5) using two wrenches, as shown. Take care not to twist or kink the supply hoses. Model 1510
Inhaltszusammenfassung zur Seite Nr. 4
Model 15101XX1 • Turn on the water supplies (1). Remove the protective cover from the sensor (2). Wait 15 seconds (3). • Place your hand in front of the sensor to turn the water on (4). Check the temperature of the water. • If adjustment of the temperature is necessary, turn the water off at the supplies (1). Remove the set screw from the rear of the faucet using a 2.5 mm allen wrench (2). • Pull the faucet housing off (1). • Use a slot-head screwdriver to adjust the temperature control screw
Inhaltszusammenfassung zur Seite Nr. 5
Change the Battery • Turn the water off at the supplies. • Both models: Remove the set screw from the rear of the faucet with a 2.5 mm allen wrench (1). • Model 15100 only: Remove the temperature control handle (2) • Pull the faucet housing off • Pull the out battery out and put the new one in (3, 4). • Reassemble the faucet and test. If the flow is unsatisfactory: Clean the aerator • Cover the sensor for 5 seconds (1). • Remove the aerator (2). • Flush the aerator thoroughly and reinstall. Cle
Inhaltszusammenfassung zur Seite Nr. 6
Replacement Parts 1 1 aerator 96788XXX 2 solenoid valve 96904000 3 fixation set 97812000 4 connection hose 96405001 5 adapter 6 electronics 96905000 7 battery Lithium CR-P2/6V or equivalent 7 8 check valve 2 6 3 4 8 5 Cleaning Recommendation for Hansgrohe Products Modern faucetry and shower products utilize a combination of materials to comply with the needs of the market with regard to design and functionality. To avoid damage, it is necessary to use some caution when cleaning. Damage caused by
Inhaltszusammenfassung zur Seite Nr. 7
Cleaning Procedures • Clean your faucets and shower products as and when required. Regular cleaning will prevent scale buildup and water spotting. • Follow the label instructions. Do not allow any cleaner to remain on the product for longer than necessary. • When using spray cleaners, spray first onto a sponge or cloth – do not spray directly onto the product. • After cleaning, rinse thoroughly with clear water to remove any cleaner residue. Important • Soap and shampoo residue can also cause
Inhaltszusammenfassung zur Seite Nr. 8
Or, call Hansgrohe toll-free at (800) 334-0455. In requesting warranty service, you will need to provide 1. The sales receipt or other evidence of the date and place of purchase. 2. A description of the problem. 3. Delivery of the product or the defective part, postage prepaid and carefully packed and insured, to Hansgrohe Inc. 1492 Bluegrass Lakes Parkway, Alpharetta, Georgia 30004, Attention: Technical Service, if required by Hansgrohe. When warranty service is completed, any repaired or repla