Inhaltszusammenfassung zur Seite Nr. 1
Lighting Systems Baselyte-BSL2
Page 1 of 8 3 Light T8 Direct/Indirect
angled lamp
Weight = 3.0 lb/ft
Ordering Information
Family Distribution Lamp Type No. of Lamps Housing Module Length Wiring Voltage Ballast Finish
BSL 6 T 03 CN
1 = 120V
T = T8 03 = 3 Light
6 = Direct/ CN = Cutout 04 = 4’ 1 = 1cct. E = Standard C = Custom Color
2 = 277V
Indirect w/baffles 08 = 8’ 2 = 2cct. <20% THD W = Standard
12 = 12’ 3 = 1cct. w/EC/NL F = Standard White
4 = 2cct. w/EC/NL <20% THD
5
Inhaltszusammenfassung zur Seite Nr. 2
Lighting Systems Baselyte-BSL2 Page 2 of 8 3 Light T8 Direct/Indirect COEFFICIENTS OF UTILIZATION Performance Candlepower Curve Candlepower Summary Coefficients of Utilization COEFFICIENTS OF UTILIZATION % EFFECTIVE CEILING CAVITY REFLECTANCE CANDLEPOWER SUMMARY 80 70 50 ZONE CANDLEPOWER % EFFECTIVE CEILING CAVITY REFLECTANCE % WALL REFLECTANCE DEG. 0 22.5 45 67.5 90 80 70 50 180 1740 1740 1740 1740 1740 50 30 10 50 % WALL REFLECTANCE 30 10 50 30 10 175 1730 1730 1733 1729 1730 50 30 10
Inhaltszusammenfassung zur Seite Nr. 3
Lighting Systems Baselyte-BSL2 Page 3 of 8 3 Light T8 Direct/Indirect Mounting Options Mount Type: T-Bar 15/16” (On-Grid)* 1-Power Mount Non-Power Mount Supension Length 1-Power Mount 2’ 4’ 8’ 12’ 3 Conductor BSLM6102P13 BSLM6104P13 BSLM6108P13 BSLM6112P13 4 Conductor BSLM6102P14 BSLM6104P14 BSLM6108P14 BSLM6112P14 7 Conductor BSLM6102P17 BSLM6104P17 BSLM6108P17 BSLM6112P17 • 65 lbs maximum load • Canopy: Diameter of 3 3/4“x 7/32” BSLM6102N BSLM6104N BSLM6108N BSLM6112N Non-Power Mou
Inhaltszusammenfassung zur Seite Nr. 4
Lighting Systems Baselyte-BSL2 Page 4 of 8 3 Light T8 Direct/Indirect Mount Type: T-Bar Fixed Position (1/4-20 Threaded Rod) 1-Power Mount 2-Power Mount Non-Power Mount Supension Length 1-Power Mount 2’ 4’ 8’ 12’ 3 Conductor BSLM2102P13 BSLM2104P13 BSLM2108P13 BSLM2112P13 4 Conductor BSLM2102P14 BSLM2104P14 BSLM2108P14 BSLM2112P14 • Meets UBC, OSHPD and DSA seismic requirements 2-Power Mount • Canopy: Diameter of 5 1/4“x 3/4” (power) BSLM2102P23 BSLM2104P23 BSLM2108P23 BSLM2112P23 3
Inhaltszusammenfassung zur Seite Nr. 5
Lighting Systems Baselyte-BSL2 Page 5 of 8 3 Light T8 Direct/Indirect Mount Type: Non-Accessible Ceilings (concrete, gypsum etc.) 1-Power Mount 2-Power Mount Non-Power Mount Supension Length 1-Power Mount 2’ 4’ 8’ 12’ 3 Conductor BSLM1102P13 BSLM1104P13 BSLM1108P13 BSLM1112P13 4 Conductor BSLM1102P14 BSLM1104P14 BSLM1108P14 BSLM1112P14 • Meets UBC, OSHPD and DSA seismic requirements 7 Conductor BSLM1102P17 BSLM1104P17 BSLM1108P17 BSLM1112P17 1/4 3/4 • Canopy: Diameter of 5 “x ” (powe
Inhaltszusammenfassung zur Seite Nr. 6
Lighting Systems Baselyte-BSL2 Page 6 of 8 3 Light T8 Direct/Indirect Wiring Options: 1 Circuit 1 Circuit Type 1: 1cct. Type 8: 1cct. w/1cct. thru wire Type H: 1cct. w/2cct. thru wire Type 7: 1cct. w/dimming All lamps wired on one circuit. 1 Circuit with Emergency Circuit/Night Light (EC/NL) Type 3: 1cct. w/EC/NL One 4’ section in a one circuit fixture to be wired on a separate thru circuit. Leads for both normal circuit and EC/NL circuit wired to fixture ends. All lamps in
Inhaltszusammenfassung zur Seite Nr. 7
Lighting Systems Baselyte-BSL2 Page 7 of 8 3 Light T8 Direct/Indirect Wiring Options: 2 Circuit Center/Outer Switching 2 Circuit Center/Outer Switching Type 2: 2cct. Type 9: 2cct. w/1cct. thru wire Type I: 2cct. w/2cct. thru wire Fixture wired for two circuit. Lamps wired for center/outer switching. 2 Circuit Center/Outer Switching with Emergency Circuit/Night Light (EC/NL) Type 4: 2cct. w/EC/NL One 4’ section in two circuit fixture (center/outer switching) to be wired on a s
Inhaltszusammenfassung zur Seite Nr. 8
Lighting Systems Baselyte-BSL2 Page 8 of 8 3 Light T8 Direct/Indirect Wiring Options: 2 Circuit A/B Switching (alternate 4’ sections) 2 Circuit A/B Switching (alternate 4’ sections) Type B: 2cct. Type A: 2cct. w/1cct. thru wire Type S: 2cct. w/2cct. thru wire Fixture wired for two circuit. Lamps wired for A/B switching in alternate 4’ sections. 2 Circuit A/B Switching (alternate 4’ sections) with Emergency Circuit/Night Light (EC/NL) Type C: 2cct. w/EC/NL One 4’ section in