Inhaltszusammenfassung zur Seite Nr. 1
METROLOGIC INSTRUMENTS, INC.
™
MS9590 VoyagerGS Series
Single-Line Hand Held Laser Scanner
Installation and User's Guide
Inhaltszusammenfassung zur Seite Nr. 2
Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc. Products identified in this documen
Inhaltszusammenfassung zur Seite Nr. 3
TABLE OF CONTENTS Introduction Product Overview............................................................................................. 1 Scanner and Accessories................................................................................. 2 Scanner Components....................................................................................... 4 Cable Installation and Removal........................................................................ 5 Labels.....................
Inhaltszusammenfassung zur Seite Nr. 4
TABLE OF CONTENTS Configuration Modes .......................................................................................... 21 Upgrading the Flash ROM Firmware.................................................................. 22 Depth of Field MS9590.......................................................................................................... 23 MS9591.......................................................................................................... 24 IR Activa
Inhaltszusammenfassung zur Seite Nr. 5
INTRODUCTION Product Overview ® The MS9590 VoyagerGS™ series is part of Metrologic’s extensive Voyager branded hand-held laser scanning product family. The VoyagerGS series is the ® first Voyager product to feature trigger scanning in its design. The VoyagerGS provides an aggressive solution for scanning all standard 1D bar codes in a new ergonomic form factor that maximizes comfort and reduces fatigue. Key product features include: • Rapid scan speed of 100 scans per secon
Inhaltszusammenfassung zur Seite Nr. 6
INTRODUCTION Scanner and Accessories BASIC KIT Part # Description MS9590 MS9590 Bar Code Scanner or or MS9591 MS9591 High-Density Bar Code Scanner 00-02544 MetroSelect Single-Line Configuration Guide MS9590 Series Single-Line Hand Held Laser Scanner 00-05150 Installation and User’s Guide Available for download at www.metrologic.com/corporate/download OPTIONAL ACCESSORIES Part # Description 46-00709 Flex Stand 46-00885 Wall Mount AC to DC Power Transformer- Regula
Inhaltszusammenfassung zur Seite Nr. 7
INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part # Description Cable Compatibility Warning Use only MS9590 series compatible product cables from the list below. Damage may occur to the scanner if incompatible cables are used. Any damage incurred from incorrect cable usage will void the limited warranty shown on page 35. RS232 PowerLink Cable with Built in Power Jack 53-53000x-3 Black Coiled Cord with Long Strain Relief Keyboard Wedge Cable with Adapter Cabl
Inhaltszusammenfassung zur Seite Nr. 8
INTRODUCTION Scanner Components No. Item Description 1 Window Laser Aperture 2 Trigger See How to use CodeGate on page 17 10-pin RJ45, Female Socket, 3 Cable Connection See Scanner Pinout Connections on page 32 4 Speaker See Audible Indicators on page 18 5 White LED See Visual Indicators on page 19 6 Blue LED See Visual Indicators on page 19 7 Yellow LED See Visual Indicators on page 19 8 Cable Release Pin-Hole See The PowerLink Cable on page 5 Figure 1. Scanner Components
Inhaltszusammenfassung zur Seite Nr. 9
INTRODUCTION Cable Installation and Removal Installation Important: If the cable is not fully latched, the unit can power intermittently. Figure 2. Connecting the Cable 1. Plug the 10-pin RJ45 end of the cable into the 10-pin socket on the scanner. There will be an audible click when the connector lock engages. 2. Gently pull on the cable strain relief to insure the cable is securely installed. Removal Before removing the cable from the scanner, Metrologic recommends
Inhaltszusammenfassung zur Seite Nr. 10
INTRODUCTION Labels Every MS9590 and MS9591 has a serial number label located on the underside of the scanner head and molded text on the scanner handle. The label and molded text provide important information such as the unit’s date of manufacture, serial number, CE and caution information. See Figure 4 for examples of these items and their location on the scanner. Figure 4 . Molded Text and Serial Number Label Caution: To maintain compliance with applicable standard
Inhaltszusammenfassung zur Seite Nr. 11
SCANNER INSTALLATION RS232 (-14) 1. Turn off the host device. 2. Plug the 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the scanner. There will be an audible click when the connector lock engages. 3. Connect the 9-pin D-type connector of the PowerLink cable to the proper COM port on the host device. If the scanner is receiving power from the host system, skip to step #6. 4. Plug the power supply into the power jack on the PowerLink cable. Ch
Inhaltszusammenfassung zur Seite Nr. 12
SCANNER INSTALLATION RS485 (-106) 1. Turn off the host device. 2. Plug the 10-pin RJ45 end of the MVC cable into the 10-pin socket on the scanner. There will be an audible click when the connector lock engages. 3. Connect the other end of the MVC cable to the host device. 4. Turn on the host device. 5. The blue LED on the scanner will turn on, the white LED will flash, and the scanner will beep once. 6. Scan the bar code below to activate the RS485 interface.
Inhaltszusammenfassung zur Seite Nr. 13
SCANNER INSTALLATION Keyboard Wedge (-47) 1. Turn off the host device. 2. Plug the 10-pin RJ45 end of the cable into the 10-pin socket on the scanner. There will be an audible click when the connector lock engages. 3. Disconnect the host device's keyboard. 4. Connect the "Y" ends of the cable to the keyboard and keyboard port on the host device. If necessary, use the male/female adapter cable supplied with the scanner cable to make the proper connections. If the sca
Inhaltszusammenfassung zur Seite Nr. 14
SCANNER INSTALLATION Stand-Alone Keyboard (-47) 1. Turn off the host system. 2. Plug the 10-pin RJ45 end of the cable into the 10-pin socket on the scanner. There will be an audible click when the connector lock engages. 3. Plug the other end of the cable into the host's keyboard port If the scanner is receiving power from the host system, skip to step #6. 4. Plug the power supply into the power jack on the PowerLink cable. Check the AC in input requirements o
Inhaltszusammenfassung zur Seite Nr. 15
SCANNER INSTALLATION USB (-106,-38-EAS, and -40-EAS) 1. Turn off the host system. 2. Plug the 10-pin RJ45 end of the USB cable into the 10-pin socket on the scanner. There will be an audible click when the connector lock engages. 3. Plug the USB Type A end of the cable into the host's USB port. Cables supplied with MS9590- 38-EAS and MS9590-40-EAS models have additional wires for Checkpoint device connections. Refer to page 12 Figure 9. for additional information o
Inhaltszusammenfassung zur Seite Nr. 16
SCANNER INSTALLATION Additional Settings for EAS Equipped Models All MS9590 models equipped with EAS capabilities have an EAS designation in their model numbers (example: MS9590-38-EAS). The cable supplied with these units will have additional wires for Checkpoint Device connections. Figure 10. EAS Cable Samples SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. The following is a list of Checkpoint recommended switch bank settin
Inhaltszusammenfassung zur Seite Nr. 17
STANDS Flex Stand Components (PN 46-00709) Item Item Description Qty. A Cradle Coupler 1 B Cradle 1 C Flexible Shaft 1 D Screw Cap 2 E Stand Base 1 F ¼" - 20 x ⅜" Flat Head Phillips Screw, 100° Undercut 2 G #8 Round Head Wood Screw 2 H M3 -.5 x 20 mm, Pan Head Phillips Screw 1 J M3 Flat Washer 1 K M3 Split Lock Washer 1 L Flexible Shaft Cover 1 Figure 12. Stand Components 13
Inhaltszusammenfassung zur Seite Nr. 18
STANDS Flex Stand Assembly (PN 46-00709) Figure 13. Stand Assembly 14
Inhaltszusammenfassung zur Seite Nr. 19
STANDS Optional Flex Stand Fixed Mount (PN 46-00709) 1. In the kit, two #8 wood screws have been provided for fixed mount applications. 2. When choosing the stand location, make sure to consider the front orientation of the stand (indicated in Figure 14). 3. On a centerline, drill two #39 pilot holes in the countertop spaced 125 mm (4.92") apart. The stand base can be used as a guide for the spacing of the pilot holes. 4. Secure the stand base to the countertop with the two
Inhaltszusammenfassung zur Seite Nr. 20
STANDS Optional Wall/Tabletop Stand Fixed Mount (PN 46-00885) 1. Drill two #39 pilot holes in the wall spaced 39 mm (1.54") apart on a horizontal centerline. 2. Install one #8 wood screw in each of the pilot holes, leaving a space between the head of the screw and the wall surface. 3. Locate the two slots marked as "A" on the stand base in Figure 16. 4. Match the "A" slots on the stand to the heads of the installed wood screws. 5. Slide the stand over the screw heads and down to