Inhaltszusammenfassung zur Seite Nr. 1
Inhaltszusammenfassung zur Seite Nr. 2
Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.
Inhaltszusammenfassung zur Seite Nr. 3
TABLE OF CONTENTS Introduction Product Overview............................................................................................. 1 Scanner and Accessories................................................................................. 2 Scanner Components....................................................................................... 4 Cable Removal................................................................................................. 4 Caution and Serial
Inhaltszusammenfassung zur Seite Nr. 4
TABLE OF CONTENTS Depth of Field Specifications Normal Scan Zone ..................................................................................... 21 Reduced Scan Zone................................................................................... 22 Depth of Field by Bar Code Element Width Normal Scan Zone ..................................................................................... 23 Reduced Scan Zone....................................................................
Inhaltszusammenfassung zur Seite Nr. 5
INTRODUCTION ™ QuantumE is a miniature, omni-directional scanning engine with optional single- line scanning capability. The self-contained device is fully enclosed eliminating the need for an external window or custom enclosure. It is designed for use in OEM equipment such as price lookup systems and kiosks. Its slim design makes it ideal for integration and use with flat-screens. Key Product Features • Fully Automatic Scanning Operation • Custom Configurable Scan Pattern •
Inhaltszusammenfassung zur Seite Nr. 6
INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No. Description ™ IS3480 QuantumE Scanner 00-02026 IS3480 Installation and User’s Guide * ® 00-02407 MetroSelect Configuration Guide * * Guides also available for download at www.metrologic.com. OPTIONAL ACCESSORIES Part No. Description AC to DC Power Transformer - Regulated 5.2VDC @ 650 mA output. 45-45593 120V United States and Canada 45-45591 220V-240V Continental European 45-45592 220V-240V United Kingdom
Inhaltszusammenfassung zur Seite Nr. 7
INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No. Description 54-54002x-3 Keyboard Wedge PowerLink cable 54-54020x-3 Stand Alone Keyboard PowerLink cable Low Speed USB Non-Locking Communication Cable 54-54235x-N-3 2.8 m (9.2') straight cord, short strain relief 49-00462 Utility Cable, 203 mm (8") Length Communication Cable, Host end Not Terminated 54-54249x-N-3 203 mm (8") straight cord, short strain relief REPLACEMENT PARTS Part No. Description 36-0182
Inhaltszusammenfassung zur Seite Nr. 8
INTRODUCTION Scanner Components Figure 1a. Scanner Components ITEM NO. DESCRIPTION 1 Utility Connector Located Under Rubber Seal The rubber seal protecting the utility connector should only be removed if the utility connector is to be used. 2 10-Pin RJ45, Female Socket 3 Blue, White and Yellow LED Indicators 4 Red Output Window (Laser Aperture) 5 Pin Hole for Cable Release 6 Speaker 7 Three M2.5 x 0.45 Threaded Mounting Points 8 Two M2.5 x 0.45 Threaded Mounting Points
Inhaltszusammenfassung zur Seite Nr. 9
INTRODUCTION Caution and Serial Number Labels Figure 2. Mounting Specifications Figure 3. Maintenance Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. 1. Spray glass cleaner onto a lint free, non-abrasive cleaning cloth. 2. Gently wipe the scanner window. 5
Inhaltszusammenfassung zur Seite Nr. 10
INSTALLATION RS232, RS232 TTL, Light Pen or Laser Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS3480. 3. Connect the 9-pin female end of the PowerLink cable to the host device. Note: Skip to step 6 if receiving power from the host device. 4. Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the v
Inhaltszusammenfassung zur Seite Nr. 11
INSTALLATION IBM 46xx or OCIA 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the IS3480. 3. Connect the other end of the MVC cable to the host device. 4. Turn on the host device. Figure 5. When the scanner first receives power, the blue LED will turn on; the scanner will simultaneously beep once and flash the white LED. Plugging the scanner into the serial port of the PC does not guarantee
Inhaltszusammenfassung zur Seite Nr. 12
INSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS3480. 3. Disconnect the keyboard from the host device. 4. Connect the “Y” end of the PowerLink cable to the keyboard and the keyboard port on the host device. If necessary, use the male/female adapter cable supplied with the scanner for proper connections. 5. Plug the external power supply into the power jack on the PowerLink cab
Inhaltszusammenfassung zur Seite Nr. 13
INSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS3480. 3. Connect the other end of the PowerLink cable to the keyboard port on the host device. 4. Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet must be located near the equipment and
Inhaltszusammenfassung zur Seite Nr. 14
INSTALLATION Low Speed USB (Integrated) 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB PowerLink cable into the 10-pin socket on the IS3480. 3. Plug the other end of the USB interface cable into the host device’s USB port. 4. Turn on the host device. As a default, the IS3480-38 leaves the factory with USB Keyboard Emulation Mode enabled. For information on configuring the IS3480-38 for USB Serial Emulation Mode, please refer to Section P: Low
Inhaltszusammenfassung zur Seite Nr. 15
INSTALLATION Notes for Laser Emulation IS3480-104 Only The IS3480-104 leaves the factory with the Laser Emulation Mode enabled. If the Recall Defaults bar code is scanned while reconfiguring the scanner the laser emulation mode will no longer be enabled. Scan the following barcode to re-enable the laser emulation interface. This feature is only supported for IS3480-104 models. Enable Laser Emulation Mode ³ 9 9997 9 11
Inhaltszusammenfassung zur Seite Nr. 16
SCANNER OPERATION Configurable Primary and Secondary Scan Pattern Modes There are two configurable scan pattern modes available with the IS3480. • The primary scan pattern mode is the default scan pattern active when the scanner starts. • The secondary scan pattern mode is activated by pressing the button located on the side of the scanner. This mode is also referred to as the button mode. For additional information on QuantumE’s button modes and an example of each, please re
Inhaltszusammenfassung zur Seite Nr. 17
SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED For illustration purposes the unit’s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 10 second button click timeout configured. 1. The primary scan pattern is active when the scanner starts. 2. To activate the secondary scan pattern, press and release the button
Inhaltszusammenfassung zur Seite Nr. 18
SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED For illustration purposes the unit’s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 10 second button click timeout configured. 1. The primary scan pattern is active when the scanner starts. 2. To activate the secondary scan pattern, press and release the butt
Inhaltszusammenfassung zur Seite Nr. 19
SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE ENABLED For illustration purposes the unit’s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 10 second button click timeout configured. 1. The primary scan pattern is active when the scanner starts. 2. To activate the secondary scan pattern, press and hold the button.
Inhaltszusammenfassung zur Seite Nr. 20
SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE DISABLED For illustration purposes the unit’s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 10 second button click timeout configured. 1. The primary scan pattern is active when the scanner starts. 2. To activate the secondary scan pattern, press and hold the button.