Inhaltszusammenfassung zur Seite Nr. 1
BARCODE IMAGER
Programming Manual
International Edition, Rev. C5
Inhaltszusammenfassung zur Seite Nr. 2
Revision History Rev. No. Released Date Description Rev.B Beta Apr. 16, 2009 First Release Page 22 Code 128/EAN-128 Setting – Modify ISBT Concatenation Off option code to “4” and ISBT Concatenation On option code to “5”. Rev.B May 05, 2009 Page 25 GS1 Databar Setting – All GS1 databar default values are changed to Enable. Page 46 Add “Symbology ID Table”. Page 34 Add “Presentation Scanning Mode”. Rev.B1 June 22, 2009 Page 37 Add “Time Delay to Low Power Mode”. Page 9
Inhaltszusammenfassung zur Seite Nr. 3
Revision History Rev. No. Released Date Description Rev. B6 May 27, 2010 Page 33 Baud Rate – Add 57.6K BPS and 115.2K BPS. Page 17 Add “UPC/EAN Security Level”. Rev. B7 Jun 25 , 2010 Page 38 Add “Immediate” parameter (option 5) to "Time Delay to Low Power Mode" and change the default value from 5 seconds to immediate. Page 15,16 Add “ Supplement Scan Voting”. Page 17 Add “EAN Supplement Control”. Page 28 Keyboard Layout – Add “Czech (QWERTY)”, remove “Unive
Inhaltszusammenfassung zur Seite Nr. 4
© Copyright Cino Group © Copyright PC Worth Int’l Co., Ltd Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information that is protected by copyright. Al
Inhaltszusammenfassung zur Seite Nr. 5
LED Eye Safety IEC62471 Exempt group Laser Eye Safety IEC60825-1 Class 1 FuzzyScan Programming Manual
Inhaltszusammenfassung zur Seite Nr. 6
Table of Contents Getting Started Getting Familiar with Your FuzzyScan 1 Connecting to Your Host 1 Using Accessories 2 Configure Your FuzzyScan Bar Code Programming Manual 3 Programming Procedures 4 Host Interface Selection 8 Symbology Reading Control 9 Keyboard Interface Control 23 Serial Interface Control 32 Wand/Laser Emulation Control 35 Operation Control 36 Condensed DataWizard 41 Appendix Symbology ID Table 48 Keyboard Function Code Table 49 ASCII Input Sh
Inhaltszusammenfassung zur Seite Nr. 7
Getting Started Getting Familiar with Your FuzzyScan Connecting to Your Host Thank you for choosing Cino FuzzyScan Imager. All FuzzyScan imagers support PS/2(DOS/V) Keyboard FuzzyScan imagers deliver world-class performance for a Wedge, RS-232 Serial, and USB interfaces. Please broad range of applications to unleash your productivity. This choose your desired interface cable, then plug it into the document provides an easy reference for installation and cable interface port of the imager an
Inhaltszusammenfassung zur Seite Nr. 8
Getting Started Using Accessories You can enhance productivity of your workforce by using various accessories to fulfill a wide variety of application demand. Universal Holder A stylish Universal Holder is designed for storing your imager when not in use. It serves to protect the imager from lens-scratched or falling. Moreover, its artistic-design enhances the entire value of the imager. Hand-free SmartStand A SmartStand is specifically designed for hand-fr
Inhaltszusammenfassung zur Seite Nr. 9
Configure Your FuzzyScan Bar Code Programming Menu The FuzzyScan bar code commands are specially designed S S S Sy y y ys s s st t t te e e em m m m C C C Co o o om m m mm m m ma a a an n n nd d d d Proprietary bar code labels which allow you to set the The System Command is the highest level bar code FuzzyScan internal programming parameters. There are command which directs FuzzyScan to perform immediate System Command, Family Code and Option Code for operations, such as enterin
Inhaltszusammenfassung zur Seite Nr. 10
Configure Your FuzzyScan P Pr ro og gr ra am mm miin ng g P Pr ro oc ce ed du ur re es s P Pr ro og gr ra am mm miin ng g P Pr ro oc ce ed du ur re es s As you scan the bar code command to select the desired If the programming family must take multiple scans parameters, information about the final selected parameters selection, cycling scan selection, or dual level selection represented by the bar code commands are stored in the procedures, the family of the programming menu will
Inhaltszusammenfassung zur Seite Nr. 11
Configure Your FuzzyScan P Pr ro og gr ra am m & & E En nd d S Sy ys st te em m L Liis st t,, G Gr ro ou up p & & M Ma as st te er r D De ef fa au ullt t P Pr ro og gr ra am m & & E En nd d S Sy ys st te em m L Liis st t,, G Gr ro ou up p & & M Ma as st te er r D De ef fa au ullt t Scan Scan “ ” “PROGRAM” SYSLIST FuzzyScan will list the product information and FuzzyScan will enter programming mode, revision number to host via selected host interf
Inhaltszusammenfassung zur Seite Nr. 12
Configure Your FuzzyScan S Siin ng glle e s sc ca an n s se elle ec ct tiio on n M Mu ullt tiip plle e s sc ca an ns s s se elle ec ct tiio on n S Siin ng glle e s sc ca an n s se elle ec ct tiio on n M Mu ullt tiip plle e s sc ca an ns s s se elle ec ct tiio on n Scan Scan Enter programming mode. “PROGRAM” Enter programming mode. “PROGRAM” Select one of desired Select one of desired Scan programming families. Scan programming families. One of Fam
Inhaltszusammenfassung zur Seite Nr. 13
Configure Your FuzzyScan C Cy yc clliin ng g s sc ca an n s se elle ec ct tiio on n D Du ua all lle ev ve ell s se elle ec ct tiio on n C Cy yc clliin ng g s sc ca an n s se elle ec ct tiio on n D Du ua all lle ev ve ell s se elle ec ct tiio on n Scan Scan “PROGRAM” Enter programming mode. Enter programming mode. “PROGRAM” Select one of desired Select one of desired Scan Scan programming families. programming families. One of Codes Family One of Fa
Inhaltszusammenfassung zur Seite Nr. 14
Configure Your FuzzyScan Host Interface Selection PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code MS IBM PS/2, 25-30 series keyboard wedge interface 02 Host Interface Selection MS Standard/TTL RS-232 peer-to-peer serial 06 MS Wand emulation 08 MS USB Com Port Emulation 09 MS PS/2 (DOS/V) direct link (keyboard replacement) 10 MS PS/2 (DOS/V) keyboard wedge turbo mode 13 MS PS/2 (DOS/V) keyboard wedge standard mode 14 MS Laser emulation 17 MS USB HI
Inhaltszusammenfassung zur Seite Nr. 15
Configure Your FuzzyScan Symbology Reading Control ♦ ♦ ♦ ♦ User Defined Symbol ID ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code 2nd Option Code DS Code 128 (default=B) 00 (1 character) Symbol ID : 1 character GS1-128 (default=C) 01 (1 character) UPC-A (default=A) 02 (1 character) EAN-13 (default=F) 03 (1 character) Codabar/NW-7 (default=D) 04 (1 character) Code 39/Code 32 (default=G) 05 (1 character) Code 93 (default=H) 06 (1 character)
Inhaltszusammenfassung zur Seite Nr. 16
Configure Your FuzzyScan Symbology Reading Control ♦ ♦ ♦ ♦ Symbology ID Transmission ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code SS Disable symbology ID transmission 0 Symbology ID Transmission SS Enable prefix CINO symbology ID transmission 1 SS Enable suffix CINO symbology ID transmission 2 SS Enable both prefix and suffix CINO symbology ID transmission 3 SS Enable prefix AIM symbology ID transmission 4 SS Enable suffix AIM symbology
Inhaltszusammenfassung zur Seite Nr. 17
Configure Your FuzzyScan Symbology Reading Control ♦ ♦ ♦ ♦ Readable Bar Code Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code SS Auto 00 Readable Symbology Setting CS Code 128 * 01 CS UPC-A * 02 CS UPC-E * 03 CS EAN-13 * 04 CS EAN-8 * 05 CS Codabar/NW-7 * 06 CS Code 39 * 07 CS Trioptic Code 39 47 CS Standard/Industrial 2 of 5 08 CS Matrix 2 of 5 38 CS Interleaved 2 of 5 * 48 CS China Postal Code 58 Remember to scan “FIN”
Inhaltszusammenfassung zur Seite Nr. 18
Configure Your FuzzyScan Symbology Reading Control ♦ ♦ ♦ ♦ Code 39/Code 32 Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code SS Disable Code 39 0 Code 39 Family Setting SS Enable Code 39 1 SS Select Standard Code 39 as primary format 2 SS Select Full ASCII Code 39 as primary format 3 SS Select Code 32 (PARAF, Italian Pharmaceutical) as primary format 4 SS Disable start/stop symbol transmission 5 SS Enable start/stop symbol tra
Inhaltszusammenfassung zur Seite Nr. 19
Configure Your FuzzyScan Symbology Reading Control ♦ ♦ ♦ ♦ Code 39 Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code SS Level 0 0 Code 39 Security Level SS Level 1 1 SS Level 2 2 SS Level 3 3 Code 39 Security Level The scanner offers four levels of decode security for Code39 bar codes: Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1, please select level 0. Level
Inhaltszusammenfassung zur Seite Nr. 20
Configure Your FuzzyScan Symbology Reading Control ♦ ♦ Codabar/NW-7 Setting ♦ ♦ ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code SS Disable Codabar 0 Codabar Setting SS Enable Codabar 1 SS Select Codabar standard format 2 SS Select Codabar ABC format 3 SS Select Codabar CLSI format 4 SS Select Codabar CX format 5 SS Disable start/stop symbol transmission 6 SS Enable ABCD/ABCD start/stop symbol transmission 7 SS Enable abcd/abcd start