Inhaltszusammenfassung zur Seite Nr. 1
ETA-S20RT
AC Distribution & Suppressor Unit
ETA-S20RT
AC Power Distribution &
AC Suppressor Unit with Remote Activation
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
– 1 – ETAsys.com
Specifications are subject to change without notice.
Inhaltszusammenfassung zur Seite Nr. 2
ETA-S20RT AC Distribution & Suppressor Unit TABLE OF CONTENTS Important Safety Instructions .................................................................................................................. 3 Introduction ........................................................................................................................................... 5 Key Features and Applications .....................................................................................................
Inhaltszusammenfassung zur Seite Nr. 3
ETA-S20RT AC Distribution & Suppressor Unit IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing)
Inhaltszusammenfassung zur Seite Nr. 4
ETA-S20RT AC Distribution & Suppressor Unit WARNING – WHEN THE DEVICE IS IN USE • T o prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to ETA Systems. • Should any of the following irregularities occur during use, immediately switch off the power , disconnect the power cord from the AC outlet and contact ETA Systems. Do not to attempt to continue operation with the product as this may cause fire or electric s
Inhaltszusammenfassung zur Seite Nr. 5
ETA-S20RT AC Distribution & Suppressor Unit INTRODUCTION Thank you for purchasing the ETA Systems ETA-S20RT AC Distribution and Suppressor Unit. The ETA-S20RT has been designed to meet most installation requirements for AC power distribution and equipment power protection. To light your rack, the ETA-S20RT incorporates a front panel USB port for lighting and equipment charging. The rear of the rack can be illuminated by the optional AP-GNL18 gooseneck LED lamp connec
Inhaltszusammenfassung zur Seite Nr. 6
ETA-S20RT AC Distribution & Suppressor Unit KEY FEATURES • 9 T otal Outlets • 6 Rear Panel Switched Outlets • 2 Rear Panel Unswitched Outlets • 1 Front Panel Unswitched Convenience Outlet • Remote Activation via Latched Dry Contact Closure or DC V oltage • Remote Status LED Power T erminals • Rear Mounted Remote Activation Bypass Switch • EPD (Emergency Power Down) to Incorporate With Fire Control Panels • EVS (Extreme V olt
Inhaltszusammenfassung zur Seite Nr. 7
ETA-S20RT AC Distribution & Suppressor Unit FRONT PANEL FEATURES 1 2 3 5 6 7 4 1. Unswitched AC Outlet The 120VAC outlet is always live when the ETA-S20RT power cord is plugged into an AC mains power source and voltage is present. Note: The AC mains power switch does not affect the Unswitched AC Outlet but it is protected with surge protection circuitry. 2. AC Mains Breaker The 20A rated breaker will open if the combined draw of all AC outlets exceeds 20A. Note: The breaker is designed to ex
Inhaltszusammenfassung zur Seite Nr. 8
ETA-S20RT AC Distribution & Suppressor Unit REAR PANEL FEATURES 5 4 3 2 1 1. AC Mains Input Connect the 14 Gauge 9' (3m) power cord to a 20A 120V AC outlet to provide power to the ET A-S20R T . 2. AC Power Outlets These six outlets are “Live” when the front panel power switch is activated. The two Unswitched Outlets are always live if the power cord is connected to 120VAC. 3. XLR Light Socket A 12VDC XLR light socket provides power for the optional AP-GNL18 lig
Inhaltszusammenfassung zur Seite Nr. 9
ETA-S20RT AC Distribution & Suppressor Unit INSTALLATION Before installing, it is recommended to read the entire manual to ensure proper operation and that all features are being utilized. The ETA-S20RT can be placed on a shelf or rack mounted in a standard 19" width rack. When rack mounted, placement within the rack is flexible however the ET A-S20R T should be within 6' of a dedicated 20A AC outlet. When rack mounting, use Rack Rail type screws of 10 ⁄32" x 1". Always make sure the 20A ou
Inhaltszusammenfassung zur Seite Nr. 10
ETA-S20RT AC Distribution & Suppressor Unit SPECIFICATIONS T ype Power Conditioner & Suppressor Load Rating 20A Safety Listings ETL (UL 60065 Standard) Front Panel Outlets 1 Unswitched USB Port 1 USB Charge/Light Port (5VDC, 1A) Activation Switch Rocker Circuit Breaker 20A Resettable Indicators AC Power On, AC Fault, EVS Protect Rear Panel AC Outlets 8 Outlets Total LED Light Socket XLR Socket to Provide 12VDC for Optional AP-GNL18 Gooseneck La
Inhaltszusammenfassung zur Seite Nr. 11
ETA-S20RT AC Distribution & Suppressor Unit NOTES: 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800-321-6699 • Fax: 800-996-3821 – 11 – ETAsys.com Specifications are subject to change without notice.
Inhaltszusammenfassung zur Seite Nr. 12
ETA-S20RT AC Distribution & Suppressor Unit LIMITED WARRANTY All products manufactured by ETA Systems are warranted to the original dealer/installer, industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications, if any. This warranty shall extend from the date of purchase for a period of one year. Additionally, fuses and lamps carry no warranty. ETA Systems will solely at its discretion, replace at no charge