Inhaltszusammenfassung zur Seite Nr. 1
PROGRAM
PRESET
IRIS RESET
System Controller WV-CU
ALARM
OPERATE
AUTO PATROL
PLAY
1
SHIFT B/W UP
PATROL STOP PATROL LEARN
ALARM
WIPER DEF
RESET
SUSPEND
AUX 1 AUX 2
CAMERA
NEAR FAR L R
SETUP
SETUP FOCUS
PROGRAM
AUTO FOCUS
HOME
PRESET
SLOW
WIDE TELE
ZOOM
CAMERA
FUNCTION
IRIS DOWN
ESC
SET CLOSE
OPEN
3
2
4
5 6
7
8 9
0
System Controller
Operating Instructions
Model No. WV-CU161
Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for futur
Inhaltszusammenfassung zur Seite Nr. 2
ENGLISH VERSION Caution: Before attempting to connect or operate this product, please read the label on the bottom. For U.S.A NOTE: This equipment has been tested and found to com- ply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to pro- vide reasonable protection against harmful interference CAUTION when the equipment is operated in a commercial environ- RISK OF ELECTRIC SHOCK ment. This equipment generates, uses, and can radiate
Inhaltszusammenfassung zur Seite Nr. 3
CONTENTS PREFACE ..................................................................................................................................................................................... 4 FEATURES ................................................................................................................................................................................... 4 PRECAUTIONS ..............................................................................................
Inhaltszusammenfassung zur Seite Nr. 4
PREFACE The WV-CU161 System Controller is designed for one-to-one use with the Combination Camera such as the WV-CS854/WV- CS654/WV-CS604 Combination Camera or the WV-RC100/WV-RC150 Receiver. Camera control is performed by multiplexing the control signal with the video signal by connecting an AV Codec or the like, or 1 via RS-485 site communication* . Alarm signals, such as motion detector signals, can be supplied to external equipment from a built-in alarm output connector. An alarm input conne
Inhaltszusammenfassung zur Seite Nr. 5
PRECAUTIONS • Refer all work related to the installation of this • Do not expose the appliance to water or moisture, product to qualified service personnel or system nor try to operate it in wet areas. installers. Do take immediate action if the appliance becomes wet. Turn the power off and refer servicing to qualified • Do not block the ventilation opening or slots on the service personnel. Moisture can damage the appliance cover. and also cause electric shock. To prevent the appliance temperat
Inhaltszusammenfassung zur Seite Nr. 6
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS Front View q w u y r t System Controller WV-CU OPERATE ALARM PATROL AUTO PLAY !3 1 2 3 SHIFT B/W UP PATROL STOP PATROL LEARN ALARM RESET WIPER DEF !4 4 5 6 SUSPEND AUX1 AUX2 CAMERA L R NEAR FAR SETUP e !5 7 8 9 FOCUS SETUP AUTO FOCUS PROGRAM HOME PRESET WIDE TELE DOWN SLOW ZOOM !6 0 CAMERA IRIS FUNCTION CLOSE OPEN ESC SET IRIS RESET PROGRAM PRESET !2 !0 !1 i o q Operate Indicator (OPERATE) r Patrol Play/Patrol Learn Button (PATROL PLAY/ Lights up wh
Inhaltszusammenfassung zur Seite Nr. 7
SET: This button is used to execute the currently high- y Auto Panning/Black and White Selection/Patrol Stop lighted setting in the Setup menu. Button (AUTO/B/W/PATROL STOP) PROGRAM PRESET: Pressing this while holding down AUTO: Pressing this button will activate the auto pan- the CAMERA SETUP/SETUP/PROGRAM button will ning function of cameras provided with this feature. program a preset position. B/W: Pressing this after pressing the SHIFT button will display the picture in black and white on t
Inhaltszusammenfassung zur Seite Nr. 8
Rear View e ALARM RS485 DATA VIDEO CAMERA POWER ALARM IN IN OUT ALARM OUT RECOVER IN T R TERM LINE ON OFF RESET OUT G B A B A ON 4 COAX OFF 2 RS485 4 3 G 2 1 ALARM IN SIGNAL GND y t r q u i !0 !1 !2 !3 !4 !5 w o q Alarm Input Terminal (ALARM IN) o Line Selection Switch (LINE 4/2) Accepts the alarm signals from external devices such This switch is used to select either Full-duplex (4-lines) as alarm sensor when the alarm switch y is in the or Half-duplex (2-lines) for the communication lines. u
Inhaltszusammenfassung zur Seite Nr. 9
SETUP The WV-CU161 can be programmed by setting switches or from the interactive Setup menu as described below. 1. DIP Switch Setting (See page 10) 2. Data Switch Setting For setting the mode of communication between the WV-CU161 and the combination camera. 3. Alarm Switch Setting For setting up the alarm terminal. Turn off the power before setting this switch. 4. Setup of WV-CU161 Display the Setup menu (see page 17) to setup the WV-CU161. Data Switch Setting Set this switch to specify the mo
Inhaltszusammenfassung zur Seite Nr. 10
CONNECTIONS Check the DIP switch settings before connecting this controller. They need to be changed only if you want to change the sys- tem settings. The following setting procedure should be made by qualified service personnel or system installers. DIP Switch Setting Caution: Unplug the AC cord before changing any DIP switch setting. Removing the Bottom Cover for SW1 Remove two screws. 1. Take off the bottom cover by removing the two screws. Bottom Cover SW1 Panasonic Removing the Botto
Inhaltszusammenfassung zur Seite Nr. 11
SYSTEM CONNECTION The WV-CU161 can be connected with a camera, a video monitor and a Time Lapse VCR. A typical connection example is shown below. Basic System Connection WV-CS854 Camera Site 900 m or less (Using RG-59U, BELDEN 9259 or equivalent cable) (Coaxial Multiplex Communication) WV-CU161 System Controller WV-CU OPERATE ALARM CAMERA AUTO PATROL PLAY 1 2 3 SHIFT B/W Control Site UP ALARM IN RESET WIPER DEF 4 5 6 SUSPEND AUX1 AUX2 CAMERA NEAR FAR L R SETUP SETUP 7 8 9 FOCUS PROGRAM AUTO FO
Inhaltszusammenfassung zur Seite Nr. 12
Connection with a Video Switcher Connected with a video switcher, the WV-CU161 allows you to control multiple combination cameras. Camera Camera Housing WV-CS854 Receiver Video Switcher System Controller DATA WV-CU161 System Controller WV-CU OPERATE ALARM PATROL AUTO 1 2 3 PLAY CAMERA SHIFT B/W UP ALARM RESET WIPER DEF SUSPEND 4 5 6 IN AUX1 AUX2 CAMERA NEAR FAR L R SETUP 7 8 9 SETUP FOCUS AUTO FOCUS PROGRAM HOME PRESET RESET WIDE TELE COAX DOWN 0 CAMERA IRIS FUNCTION ESC SET CLOSS OPEN IRIS RE
Inhaltszusammenfassung zur Seite Nr. 13
RS-485 Site Communication Connection via Codec for Camera Distance of 1 200 m (4 000 ft) or More RS-485 Cable Coaxial Cable DATA PORT WV-CS854 AV Codec Public lines AV Codec VIDEO OUT DATA PORT System Controller WV-CU OPERATE ALARM AUTO PATROL PAY 1 2 3 SHIFT B/W CAMERA IN UP ALARM RESET WIPER DEF 4 5 6 SUSPEND AUX1 AUX2 CAMERA NEAR FAR L R SETUP SERUP 7 8 9 FOCUS PROGRAM AUTO FOCUS HOME PRESET WIDE TELE RESET DOWN CAMERA 0 FUNCTION CLOSS IRIS OPEN ESC SET IRIS RESET PROGRAM PRESET VIDEO OUT V
Inhaltszusammenfassung zur Seite Nr. 14
Connection with a Time Lapse VCR Connect the time lapse VCR as shown in the example below. Make sure the polarity of the buzzer matches the terminal. Connect the positive (+) terminal of the buzzer to the Alarm Output Terminal. The Alarm Output Terminal is an Open Collector terminal with a capacity of 16 V DC, 100 mA or less. (1) Connect the buzzer as shown below if its rating lies within the capacity of the Alarm Output Terminal. (2) Use an external relay unit as shown below if the buzzer rat
Inhaltszusammenfassung zur Seite Nr. 15
RS-485 Terminal Control data is transmitted and received to and from other peripherals. Use a data grade, double-shielded, twisted pair cable, suitable for the RS-485. Cable length may be extended up to 1 200 m (4 000 ft). TR G B A B A RS485 5 432 1 TB TA RB RA GND Internal Diagram 4 TB 3 TA 2 RB 1 RA 15
Inhaltszusammenfassung zur Seite Nr. 16
SETUP MENU The Setup menu has four main submenus: Alarm Setup, System Setup, Preset Data Load, and Communication. All of these main menus are further divided into submenus. SETUP MENU 1 ALARM SETUP* ALARM TERMINAL 2 SYSTEM SETUP* 3 PRESET DATA LOAD* PRESET DATA LOAD CAM 1 PRESET DATA LOAD CAM 2 PRESET DATA LOAD CAM 3 PRESET DATA LOAD CAM 4 PRESET DATA LOAD CAM 5 PRESET DATA LOAD CAM 6 PRESET DATA LOAD CAM 7 PRESET DATA LOAD CAM 8 4 CO
Inhaltszusammenfassung zur Seite Nr. 17
• Joystick Controller Displaying the Setup Menu 1. Check that the camera, the monitor and peripherals are LR Up: To select modes. connected correctly and securely. DOWN 2. Switch all the system components on. UP The operate indicator of the WV-CU161 lights up. LR Down: To select modes. The picture of the camera appears on the monitor. 3. Press the SHIFT button, and then press the CAMERA UP SETUP/SETUP button for 2 seconds or more. 4. The SETUP MENU appears. R Left: To decrease the parameter. D
Inhaltszusammenfassung zur Seite Nr. 18
• For using alarm input terminals 1-4 3. Select the desired alarm output duration, 1S-30S, 40S 50S 1MIN 2MIN, 3MIN, 4MIN, 5MIN EXT, or OFF by ALARM SETUP moving the joystick to the right or left. The initial factory setting is 10S. ALARM DISPLAY ON SITE ALARM ON EXT: The alarm signal continues to be output from the TERM.ALARM ON alarm output connector till the alarm is reset. The ALARM OUTPUT 10S ALARM BUZZER ON alarm is not automatically reset. ALARM TERMINAL 1S-
Inhaltszusammenfassung zur Seite Nr. 19
• For using alarm input terminals 1-4 System Setup 1. Display the Setup menu. ALARM SETUP 2. Select SYSTEM SETUP by moving the joystick up or ALARM DISPLAY ON down. SITE ALARM ON 3. Press the PRESET/SET/PROGRAM PRESET button. TERM.ALARM ON ALARM OUTPUT 10S The SYSTEM SETUP menu appears on the monitor as ALARM BUZZER ON shown below. ALARM TERMINAL SYSTEM SETUP CABLE COMP S SWITCH BUZZER ON 1. Display the ALARM SETUP menu. 2. Select ALARM TERMIN
Inhaltszusammenfassung zur Seite Nr. 20
7. While downloading, the word LOADING blinks on the Preset Data Load Setting right. 1. Display the Setup menu. changing to in the progress bar indicates the P 2. Select PRESET DATA LOAD by moving the joystick up progress of downloading. or down. 8. When downloading is completed, END appears on the 3. Press the PRESET/SET/PROGRAM PRESET button. right. The progress bar disappears. The PRESET DATA LOAD screen appears on the moni- 9. Editing the DATA TITLE. tor as shown below. For further infor