Inhaltszusammenfassung zur Seite Nr. 1
D268, D269 Independent Zone Control
Operation and Installation Manual
Inhaltszusammenfassung zur Seite Nr. 2
D268, D269 Notice Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable. However, Radionics, Inc. assumes no responsibility for inaccuracies and reserves the right to modify and revise this manual without notice. It is our goal at Radionics to always supply accurate and reliable documentation. If a discrepancy is found in this documentation, please mail a photocopy of the corrected material to: Radionics, Inc., Radion
Inhaltszusammenfassung zur Seite Nr. 3
D268, D269 Description Description The D268/269 Independent Zone Control Modules are accessory devices for use with Radionics control/ communicators. You can use the D268/D269 to arm and disarm a single 1k Ω zone of a D4112, D6112, or D8112 or single 1k Ω point of a D7112 or D9112 Control/Communicator panel. The D268/D269 features a user programmable passcode and can initiate Opening/Closing reports by zone or point when the panel is programmed for this response. You can install up to four D269
Inhaltszusammenfassung zur Seite Nr. 4
D268, D269 Operation Operation (continued) Open/Close Output This output presents an open circuit to the panel when the D268/D269 is disarmed, and a normal circuit when the D268/D269 is armed and not in alarm. Alarm Output Terminals Two form C contacts, each rated at 2 Amps, are provided for an optional alarm device, such as a bell. This relay is activated when the D268/D269 goes into alarm, and is reset when the D268/D269 is disarmed. A D136 Relay needs to be installed in the D268 for this o
Inhaltszusammenfassung zur Seite Nr. 5
D268, D269 Programming Programming or Changing the Passcode (continued) 1. Press the center bottom blank key once (see Figure 1). 2. Enter the old passcode once (1234 or 2222 when first installed). 3. Enter the new four digit passcode twice. 4. Arm and disarm the D268/D269 to test the new passcode. 5. Place jumper J1 in the desired position (“B” to prevent passcode changes, “A” to enable passcode changes). Note: After programming the passcode, loss of power to the D268 for 24 hours or more
Inhaltszusammenfassung zur Seite Nr. 6
D268, D269 Programming Figure 2: D268 Module Using the D268 Module with the D8112 Control/Communicator The D268 controls arming/disarming and entry/exit delay for the zone input to which it is connected. Sub-control zones use distinctive zone codes which do not follow typical zone code programming rules. The first two digits of the zone code follow Special Zone Code programming. The last two digits follow standard programming parameters. (See the 8112: MAIN Program Entry Guide, Section 22.4 for
Inhaltszusammenfassung zur Seite Nr. 7
D268, D269 Programming D8112 Control/Communicator Audible Alarms The D8112 can be programmed to sound an audible alarm from its alarm output when the D268/D269 is tripped while armed. The D8112 must be programmed with a bell time and the D8112 zone code must be programmed for audible alarms. RECOMMENDED ZONE CODES FORMAT J2* on D268 Digit 1 Digit 2 Digit 3 Digit 4 No Opening /Closing Audible A or B 3 4 3 or 7 1 - 8 Silent A 3 4 1 or 5 1 - 8 Priority Zone B 3 4 1, 3, 5, 7 3, 4, 7, 8 Opening/Clos
Inhaltszusammenfassung zur Seite Nr. 8
D268, D269 Installation D268 Module Installation Mounting the D268 The D268 Independent Zone Control Module is suitable for installation in a D8103 Enclosure or a D8108A Attack Resistant Enclosure. Both enclosures available for UL certified Local and Central Station Grade A or B, and Police connected burglar alarm applications. Align the D268 Module with any of the four mounting locations, and fasten the module in place with the three mounting screws provided. Wiring the D268 Three wires are use
Inhaltszusammenfassung zur Seite Nr. 9
D268, D269 Installation Figure 4: Wiring the D268/D269 D268, D269 Operation and Installation Copyright © 2001 Radionics Page 9 74-04758-000-H
Inhaltszusammenfassung zur Seite Nr. 10
D268, D269 Installation D268, D269 Operation and Installation Manual 74-04758-000-H Page 10 Copyright © 2001 Radionics
Inhaltszusammenfassung zur Seite Nr. 11
D268, D269 Installation D269 Keypad Installation The D269 Keypad is shipped with a faceplate, a backbox/circuit assembly, a 4-wire cable, two mounting screws, two collapsible clips, and two wall mounting plates. The keypad installs flush to the wall surface, and may be installed into a single-gang box, if desired. Do not mount the D269 in a location exposed to direct sunlight, this may make the LEDs less visible. Follow the directions below for mounting. 1. To install the D269 flush with the wal
Inhaltszusammenfassung zur Seite Nr. 12
D268, D269 Installation Wiring the D269 Keypads You can wire up to four D269 Keypads in parallel to the D268 Module (see Figure 4). You must install at least one D269. A cable with a four pin connector and four wire leads is supplied with each keypad. The furthest D269 can be located a maximum of 500 feet away from the panel enclosure. Using a larger gauge wire does NOT increase this distance. UL certificated installations: UL certifications require a D8108A Attack Resistant Enclosure, and a 1
Inhaltszusammenfassung zur Seite Nr. 13
D268, D269 Installation Figure 8: Zone Control Outside the Main Protected Premises You can connect up to eight D268 modules to a single panel. Each D268 can be connected to a D269 that has a unique combination. This configuration is useful in multiple premises applications (see Figure 9). Instant zones can be used for sub-zone protection, and delay zones can be used for premises entry. Protected wiring (Figure 5) is required for the connection of the D268 sub-zones. Figure 9: Multiple Premises
Inhaltszusammenfassung zur Seite Nr. 14
D268, D269 Installation D268/D269 Configurations (continued) For applications requiring more than four D268 Modules, install a second enclosure to house the additional modules (see Figure 10). Wires for the additional Modules feed through rigid conduit or electrical metallic tubing installed on the outside of both enclosure. Figure 10: Multiple D268 Module Installation D268, D269 Operation and Installation Manual 74-04758-000-H Page 14 Copyright © 2001 Radionics
Inhaltszusammenfassung zur Seite Nr. 15
D268, D269 Specifications Specifications Operating Voltage: Nominal 12 VDC supplied from the panel auxiliary power supply. Current Requirements: D268: 20mA, zones normal 50mA, sub-system in alarm D269: 30mA , sub-system armed 60mA, entry delay Optional Alarm Device Contacts: Form C contacts, 2 Amps maximum D269 Keypad Dimensions (H x W x D): 4.6 in. x 3.1 in. x 1.8 in. (11.7 cm. x 7.9 cm. x 4.6 cm.) Keypad Wiring: 22 AWG 4-wire cable is required. A maximum of 500 feet of cable may be used to c
Inhaltszusammenfassung zur Seite Nr. 16
© 2001 Radionics, a division of Detection Systems, Inc. 74-04758-000-H 8/01 PO Box 80012, Salinas, CA 93912-0012 USA Operation and Installation D268, D269 Customer Service: (800) 538-5807 Page 16 of 16