Inhaltszusammenfassung zur Seite Nr. 1
SSA-R2001
RFID Reader
User Manual
imagine the possibilities
Thank you for purchasing this Samsung product.
To receive more complete service,
please visit our website.
www.samsungsecurity.com
Inhaltszusammenfassung zur Seite Nr. 2
safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit. This exclamation point symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accom
Inhaltszusammenfassung zur Seite Nr. 3
SAFETY INFORMATION 5. Keep out of direct sunlight and heat radiation sources. It may cause fi re. 6. Install it in a place with good ventilation. 7. Avoid aiming the controller directly towards extremely bright objects such as sun. 8. Apparatus shall not be exposed to dripping or splashing and no objects fi lled with liquids, such as vases, shall be placed on the apparatus. 9. The Mains plug is used as a disconnect device and shall stay readily operable at any time. FCC Statement This device comp
Inhaltszusammenfassung zur Seite Nr. 4
contents 5 Features PRODUCT INTRODUCTION 5 What’s included 6 At a Glance 7 Cable Color Scheme 5 7 Cable Selection 8 Installation INSTALLATION AND EXTERNAL 9 Precautions on installation CONNECTION 10 External Connection 8 11 Output Format INITIALIZATION 12 Basic Operations 11 13 WIEGAND Output OUTPUT FORMAT 14 RS-232 Output 15 4/8 BIT BURST Output Format 13 16 Trouble Shooting TROUBLE SHOOTING 16 17 Product Specifi cation PRODUCT SPECIFICATION 17 4_ Contents
Inhaltszusammenfassung zur Seite Nr. 5
PRODUCT INTRODUCTION product introduction FEATURES This product is an elegant-looking proximity reader equipped with the built-in keypad, which has the maximum of 10cm (4”) read range. It is also supported by backlighting on the keypad, enabling stable operation at night. This product permits user access through authentication of the contactless card and personal identifi cation number using the keypad. Red, green and orange LED indicators and the built-in buzzer ensure reliable and accurate
Inhaltszusammenfassung zur Seite Nr. 6
product introduction AT A GLANCE Front/Rear 6 5 7 4 3 8 1 LED Displays the status of the system operation. 2 Keypad Used to enter the ID/password. 2-PIN Connector Can be connected to the power cable. 3 6-PIN Connector Can be connected to Wiegand, RS-232 communication cables. 4 8-PIN Connector Connected to the tamper, LED and buzzer control connection cables. 5 Output Selection Switch Switch that allows you to select an output from 8 bit, 4 bit Burst and Wiegand. 6 7 Tamper Switch Tam
Inhaltszusammenfassung zur Seite Nr. 7
PRODUCT INTRODUCTION CABLE COLOR SCHEME ❖ 2-PIN Connector I/O Pins Signal Cable Color Power (+12V) DC +12V Red Earth-grounding GND (-) Black ❖ 6-PIN Connector I/O Pins Signal Cable Color Wiegand Data Output 0 WIK_DATA0 Green Wiegand Data Output 1 WIK_DATA1 White Not Used Not Used Orange RS-232 TX TX OUT Purple Not Used Not Used Brown RS-232-GND GND Black ❖ 8-PIN Connector I/O Pins Signal Cable Color Tamper Switch NC Tamper NC Green with White Stripes Tamper Switch COM Tamper COM Gray LED Contro
Inhaltszusammenfassung zur Seite Nr. 8
installation and external connection INSTALLATION 1. Attach the provided rear panel to the wall and drill two 6-32 holes and one 1/2 inch hole on it. (See [Figure 1]) 2. Refer to [Figure 2] below on how to secure the rear panel to the wall using the provided screws. 3. Apply each of 5 O-rings to the corresponding point as shown in [Figure 2]. 4. Fix the main unit with the rear panel by inserting the main unit’s cables into the center hole and pushing the main unit towards the rear panel.
Inhaltszusammenfassung zur Seite Nr. 9
INSTALLATION AND EXTERNAL CONNECTION PRECAUTIONS ON INSTALLATION IF INSTALLING ON A METAL WALL If you install the reader on a metal wall, the read range may be reduced. To avoid this problem, it is recommended to insert the spacer between the metal wall and the reader as shown below. Metal Wall Spacer Reader IF INSTALLING MORE THAN ONE READER SIDE BY SIDE OR FRONT AND BACK If you install more than one reader side by side or front and back, the read range may be reduced. In this
Inhaltszusammenfassung zur Seite Nr. 10
installation and external connection EXTERNAL CONNECTION WIRING DIAGRAM SSA-R2001 Wiegand Data 0 Out Green Wiegand Data 1 Out White Tamper Switch Out(NC) Green with white stripes Tamper Switch Out(COM) Gray RS-232(TX) Purple PC CONTROLLER Buzzer Control In Blue White with red stripes LED Control In(Red) RS-232(GND) Black LED Control In(Green) Yellow LED Control In(Orange) Blue with white stripes Red Black DC +12V GND POWER Category Cable Color Connect the DC+12V to the red line. Po
Inhaltszusammenfassung zur Seite Nr. 11
INITIALIZATION initialization OUTPUT FORMAT You can adjust the output format of the numeric values from the keypad. You can select 4/8 bit Burst or 34bit Wiegand. Adjust the format according to the controller receiving the keypad input. 1. To change the output format, use the switch on the rear of the product. ON 12 2. See the table below to make adjustment as needed. ❖ Output Format SW #1 SW #2 Output Format of Card Output Format of Keypad ON ON 34bit Wiegand + RS-232 34bit Wiegand+RS-232 ON O
Inhaltszusammenfassung zur Seite Nr. 12
initialization BASIC OPERATIONS Initial State (when the power is supplied) When you apply power to the product, it will sound beep three times before entering Standby with the red indicator turned on. Using the card Present the card to the product until you hear a beep and the green indicator turns on. The reader keeps the green indicator turned on while transferring the card data to the controller. When it is done, the green indicator turns off and for receiving the next
Inhaltszusammenfassung zur Seite Nr. 13
OUTPUT FORMAT output format WIEGAND OUTPUT Timing Diagram Data Format (34-bit) • Bit 1 : Even Parity (bit 2 ~ bit 17) • Bit 2~Bit33 : 4-byte ID Number • Bit 34 : Odd Parity (bit 18 ~ bit 33) English13
Inhaltszusammenfassung zur Seite Nr. 14
output format RS-232 OUTPUT Output Waveform Indeterminate Region 8 Data Bits 2 Stop Bits Start Bit Data packet corresponding to ASCII character ‘A’ Data Type START (0X02H) DATA (10 Char) END (0x03H) LRC START(0X02H) DATA (10 Char) END (0x03H) LRC Check the following settings: M Baud Rate : 9600bps Data Bit : 8 Parity Bit : None Stop Bit : 1 LRC : This is the result of XOR operation of each byte from Start to End. 14_ Output Format
Inhaltszusammenfassung zur Seite Nr. 15
OUTPUT FORMAT 4/8 BIT BURST OUTPUT FORMAT 4Bit Burst Output Format Keypads Binary Hexa Keypads Binary Hexa 0 0000 0 6 0110 6 1 0001 1 7 0111 7 2 0010 2 8 1000 8 3 0011 3 9 1001 9 4 0100 4 ESC 1010 A 5 0101 5 ENT 1011 B 8Bit Burst Output Format Keypads Binary Hexa Keypads Binary Hexa 0 11110000 F0 6 10010110 96 1 11100001 E1 7 10000111 87 2 11010010 D2 8 01111000 78 3 11000011 C3 9 01101001 69 4 10110100 B4 ESC 01011010 5A 5 10100101 A5 ENT 01001011 4B English15
Inhaltszusammenfassung zur Seite Nr. 16
troubleshooting TROUBLESHOOTING If the product does not function properly, please see the below for trouble shooting. If the trouble persists, please contact the SAMSUNG Customer Service near you. PROBLEM SOLUTION My card is not read properly. 1) Check the rated voltage specifi ed in the user manual and the catalog. 2) Ensure that you are using an ISO14443 Type A card. - Cards of 125 kHz format can not be used. However, the 13.56 MHz card can not be used if it is of Type B, ISO15693. (
Inhaltszusammenfassung zur Seite Nr. 17
product specifi cations PRODUCT SPECIFICATIONS Item SSA-R2001 Power / Current DC 12V / Max.75mA Reading Time (Card) 30ms Input Port 2 ea : External LED Control, External Buzzer Control Output Port 34bit Wiegand, 4/8bit Burst for PIN (Selectable) LED Indicator 3 LED Indicators (Red, Green and Orange) Beeper Piezo Buzzer Keypad 12 Key Numeric Keypad with Back Lighting Operating Temperature -25°C to +50°C Operating Humidity 10% to 90% Relative Humidity Non-Condensing Color / Material Silver with
Inhaltszusammenfassung zur Seite Nr. 18
Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the environment or human health from uncontrolled waste dispos