Inhaltszusammenfassung zur Seite Nr. 1
Installation Manual
P/N 20002298, Rev. C
September 2007
®
Micro Motion
F-Series Sensor
Installation Manual
Inhaltszusammenfassung zur Seite Nr. 2
Inhaltszusammenfassung zur Seite Nr. 3
Before You Begin Before You Begin ® This manual describes how to install a Micro Motion F-Series sensor. The following information is provided in this manual: Customer service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1 Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2 European installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inhaltszusammenfassung zur Seite Nr. 4
Before You Begin Specifications Full product specifications can be found in the F-Series Product Data Sheet, which is available from the Micro Motion web site at www.micromotion.com. Definitions ™ The term MVD transmitter refers to the following transmitter models: � Models 1500, 1700, 2500, and 2700 � Models 3500 and 3700 The term high-temperature sensor refers to the following F-Series models: � F025A and F025B � F050A and F050B � F100A or F100B The term extreme high-temperature sensor refe
Inhaltszusammenfassung zur Seite Nr. 5
Before You Begin Figure 1 F-Series sensor with core processor Calibration tag Core processor housing Approval tag Flow direction arrow Process connection Sensor with purge fittings Purge fitting Core processor housing Purge fitting Approval tag Calibration tag Sensor Installation: F-Series 3
Inhaltszusammenfassung zur Seite Nr. 6
Before You Begin Figure 2 F-Series sensor with integrally mounted Model 1700/2700 transmitter Model 1700/2700 transmitter Core processor housing Calibration tag Approval tag Process connection Flow direction arrow Sensor with purge fittings Model 1700 or 2700 transmitter Purge fitting Purge fitting Approval tag Calibration tag 4 Sensor Installation: F-Series
Inhaltszusammenfassung zur Seite Nr. 7
Before You Begin Figure 3 F-Series sensor with junction box Approval tag Junction box Calibration tag Process connection Flow direction arrow Sensor with purge fittings Purge fitting Junction box Purge fitting Approval tag Calibration tag Sensor Installation: F-Series 5
Inhaltszusammenfassung zur Seite Nr. 8
Before You Begin Figure 4 F-Series sensor with integrally mounted IFT9701 transmitter Model IFT9701 transmitter Calibration tag Approval tag Process connection Flow direction arrow Sensor with purge fittings Model IFT9701 transmitter Purge fitting Purge fitting Approval tag Calibration tag 6 Sensor Installation: F-Series
Inhaltszusammenfassung zur Seite Nr. 9
Before You Begin Figure 5 High-temperature or extreme high-temperature F-Series sensor with flexible conduit Transmitter, core processor, or junction box (core processor shown) Flexible conduit Approval tag Calibration tag Process connection Flow direction arrow Sensor Installation: F-Series 7
Inhaltszusammenfassung zur Seite Nr. 10
Determining a Location Step 1 Determining a Location Choose a location for the sensor based on the requirements described in this section. The following general guidelines can help you select an appropriate location for the sensor. Full flow tubes For optimal performance, the sensor tubes should remain full of process fluid. Hazardous area installations Make sure the hazardous area specified on the sensor approval tag is suitable for the environment in which the sensor is installed (see Figur
Inhaltszusammenfassung zur Seite Nr. 11
Determining a Location Figure 6 F-Series sensor ambient and process temperature limits (all models except high-temperature and extreme high-temperature models) Mount electronics remotely; use junction box 176 (80) 158 (70) 140 (60) 104 (40) 91 (33) 68 (20) 32 (0) –4 (–20) –40 (–40) –76 (–60) Mount electronics remotely; use junction box –112 (–80) –148 (–100) Maximum process temperature in °F (°C) Notes: 1. When ambient temperature is below –40 °F (–40 °C), a core processor must be heated to bri
Inhaltszusammenfassung zur Seite Nr. 12
Determining a Location Figure 7 F-Series sensor ambient and process temperature limits (high-temperature and extreme high-temperature models) 176 (80) 140 (60) 104 (40) High-temp. models 68 (20) 32 (0) Extreme high-temp. models –4 (–20) –40 (–40) –76 (–60) Mount electronics remotely; use junction box –112 (–80) –148 (–100) Maximum process temperature in °F (°C) Notes: 1. When ambient temperature is below –40 °F (–40 °C), a core processor must be heated to bring its local ambient temperature t
Inhaltszusammenfassung zur Seite Nr. 13
Determining a Location Maximum wiring distances If the transmitter is mounted remotely from the sensor, the maximum distance between the sensor and transmitter depends on cable type. See Table 2. For high-temperature and extreme high-temperature F-Series sensors, note the following: � For sensors with a Model 1700/2700 transmitter, the transmitter is considered to be integrally mounted on the sensor, so Table 2 does not apply. � For sensors with a junction box or core processor, the limits in
Inhaltszusammenfassung zur Seite Nr. 14
Orienting the Sensor Step 2 Orienting the Sensor The sensor will function properly in any orientation if the sensor tubes remain filled with process fluid. Micro Motion recommends orienting F-Series sensors as shown in Figure 8. Figure 8 Recommended sensor orientations Slurries and Gases Liquids self-draining applications Tubes up Tubes down Flag mount Horizontal pipeline Horizontal pipeline Vertical pipeline Flow Self-draining applications The F-Series sensor is self-draining when it is ins
Inhaltszusammenfassung zur Seite Nr. 15
Mounting the Sensor Step 3 Mounting the Sensor Use your common practices to minimize torque and bending load on process connections. Figure 9 illustrates how to mount the sensor. To reduce the risk of condensation or excessive moisture, the conduit opening should not point upward (if possible). The conduit opening of the junction box or core processor can be rotated freely to facilitate wiring. Figure 9 Mounting an F-Series sensor Sensor Installation: F-Series 13
Inhaltszusammenfassung zur Seite Nr. 16
Mounting the Sensor Mounting the electronics of high-temperature and extreme high-temperature sensors High-temperature and extreme high-temperature F-Series sensors come with a 32 ″ (812 mm) pre-installed flexible conduit. This conduit is required for agency approval. A factory-supplied Model 1700/2700 transmitter, core processor, or junction box is connected to the end of the flexible conduit. Mount the electronics to a wall or instrument pole using the supplied bracket (Figure 10). Figure
Inhaltszusammenfassung zur Seite Nr. 17
Wiring Step 4 Wiring Improperly sealed housings can expose electronics to moisture, which can cause measurement error or flowmeter failure. Inspect and grease all gaskets and O-rings. Fully close and tighten all housing covers and conduit openings. Installation options The sensor has one of the following electronics configurations: � An integral Model 1700/2700 or IFT9701 transmitter. No wiring is required between the sensor and the transmitter. Skip to Grounding on page 19. � A core processo
Inhaltszusammenfassung zur Seite Nr. 18
Wiring Figure 11 Micro Motion cable gland and heat shrink 4 1/2 in (114 mm) 3/4 in (19 mm) Gland clamping Gland nut insert 7/8 in (22 mm) 7/8 in (22 mm) Gland body Shielded heat shrink 4. For connection at the core processor housing, prepare shielded cable as follows (for armored cable, omit steps d, e, f, and g): a. Strip 4 1/2 inches (114 mm) of cable jacket. b. Remove the clear wrap that is inside the cable jacket, and remove the filler material between the wires. c. Remove the foil shi
Inhaltszusammenfassung zur Seite Nr. 19
Wiring Figure 13 Applying the heat shrink g. Position gland clamping insert so the interior end is flush with the heat shrink. h. Fold the cloth shield or braid and drain wires over the clamping insert and approximately 1/8 inch (3 mm) past the O-ring. Figure 14 Folding the cloth shield i. Install the gland body into the core processor housing conduit opening. Figure 15 Gland body and core processor housing 5. Insert the wires through the gland body and assemble the gland by tightening the glan
Inhaltszusammenfassung zur Seite Nr. 20
Wiring Figure 16 Connecting the wires at the core processor Terminal 1 Power supply + (Red wire) Terminal 4 RS-485B (Green wire) Terminal 3 RS-485A (White wire) Terminal 2 Power supply – (Black wire) Core processor housing internal ground screw � For connections to earth ground (if core processor cannot be grounded via sensor piping and local codes require ground connections to be made internally) � Do not connect shield drain wires to this terminal 7. Reinstall and tighten the core processor