Inhaltszusammenfassung zur Seite Nr. 1
D9412GV2/D7412GV2
Operation and Installation Guide
EN Control Panels
Inhaltszusammenfassung zur Seite Nr. 2
D9412GV2/D7412GV2 | Operation and Installation Guide | Trademarks Trademarks Federal Communications ® CoBox is a registered trademark of Lantronix . Commission (FCC) Rules ® Windows is a registered trademark of Microsoft Part 15 Corporation in the United States or in other countries. This equipment was tested and found to comply with ® Molex is a registered trademark of Molex the limits for a Class A digital device, pursuant to Part Incorporated. 15 of the FCC rules. These limits a
Inhaltszusammenfassung zur Seite Nr. 3
D9412GV2/D7412GV2 | Operation and Installation Guide | Federal Communications Commission (FCC) Rules . If the D9412GV2 or D7412GV2 Control Panel causes harm to the telephone network, the telephone company attempts to notify you in advance. If advance notice is not practical, the telephone company notifies you as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilit
Inhaltszusammenfassung zur Seite Nr. 4
D9412GV2/D7412GV2 | Operation and Installation Guide | Contents 4.6.5 Poweringing Up................................................ 18 4.7 Programming the Control Panel .................... 19 Contents 4.8 Installing the Point Chart Label ..................... 19 1.0 Introduction.......................................................7 4.9 Testing the System ........................................... 19 2.0 Lightning Strikes ..............................................8 5.0 Power S
Inhaltszusammenfassung zur Seite Nr. 5
D9412GV2/D7412GV2 | Operation and Installation Guide | . 8.5 Wiring Information for Installations 11.2.2 Installation......................................................... 53 Using the Ademco AB-12 Bell/Housing........32 11.3 D268/D269 Independent Zone Control, 9.0 Off-Board Points .............................................34 D279A Independent Zone Control................ 55 9.1 Point (Zonex) Bus: D9412GV2 Terminals 11.4 Keyswitch..................................................
Inhaltszusammenfassung zur Seite Nr. 6
D9412GV2/D7412GV2 | Operation and Installation Guide | 1.0 Introduction Figure 35: D9412GV2, Input Points and Peripheral Devices .................................... 65 Figures Figure 36: D9412GV2, SDI Devices......................... 66 Figure 1: System Configuration .................................9 Figure 37: D7412GV2, Power Supply Side.............. 67 Figure 2: Enclosure Mounting..................................15 Figure 38: D7412GV2, Input Points and Figure 3: Ground Fault D
Inhaltszusammenfassung zur Seite Nr. 7
D9412GV2/D7412GV2 | Operation and Installation Guide | Tables . 1.0 Introduction This manual addresses the operation and installation of the D9412GV2 and D7412GV2 Control Panels. Throughout this guide, the words “control panel” refer to both control panels (D9412GV2 and D7412GV2). Table 2 on page 9 provides an overview of the differences between the D9412GV2 and D7412GV2 control panels. Table 1: Related Documentation ∗ Name of Documentation Part Number D1255 Installation Instructions 7
Inhaltszusammenfassung zur Seite Nr. 8
D9412GV2/D7412GV2 | Operation and Installation Guide | 2.0 Lightning Strikes 2.0 Lightning Strikes The control panels are designed to significantly reduce electromagnetic interference and malfunction generally caused by lightning. 2.1 Effects Any electronic system can be struck directly by lightning or be adversely affected by a lightning strike near the system. When lightning strikes, several things happen: • An electromagnetic wave spreads from the point of the strike inducin
Inhaltszusammenfassung zur Seite Nr. 9
D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview . 3.0 Overview 3.1 Configuration and Parts Figure 1: System Configuration D8129 OctoRelay provides alarm D9210B Modules can be and auxiliary relay output. used for access control. (Other functions available.) Each D8128D OctoPOPIT combines DX4020 allows communciation eight POPIT points in one module. over a Local or Wide Area Network (LAN/WAN). Control Panel D8125, D8125INV, or D8125MUX Interface D928 Module allows the cont
Inhaltszusammenfassung zur Seite Nr. 10
D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview 3.1.2 Parts Available by Separate Order 3.1.1 Parts List Order the following components separately to The D9412GV2 andD7412GV2 Control Panels are complete a basic eight-point installation. shipped assembled from the factory with the following parts: • D1255, D1256, D1257, D1260, or D720 Command Center (or keypad) Literature Pack • D1640 Transformer • D9412GV2/D7412GV2/D7212GV2 Installation and • D126 or D1218 Batt
Inhaltszusammenfassung zur Seite Nr. 11
D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview . 3.2 Accessories Refer to the Bosch Security Systems product catalog for additional information. Table 3: Compatible Accessories Model Title Model Title D122/D122L Dual Battery Harness D1260 Alpha V Command Center D125B Powered Loop Interface Module D1640 16.5 VAC 40 VA Transformer D127 Reversing Relay D5200 Programmer D129 Dual Class A Initiation Circuit D5500 Remote Programming Software (RPS) Module D130 Relay Mo
Inhaltszusammenfassung zur Seite Nr. 12
D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview 3.3.5 Points 3.3 Features in the D9412GV2 and The Bosch Security Systems D9412GV2 Control Panel D7412GV2 provides up to 246 points of protection. The 3.3.1 SDI Molex Connector D7412GV2 Control Panel provides up to 75 points of Use the SDI Molex Connector to connect easily an protection. Point programming parameters determine SDI device with the SDI bus, without needing to the control panel response to open and short
Inhaltszusammenfassung zur Seite Nr. 13
D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview . The system can route groups of Event Reports to four • Request to enter (RTE) or request to exit (REX) different destinations. Each report group can be input programmed to send reports to one or more • Keypad destinations. Primary and backup reporting paths can The access control features of the D9412GV2 and be programmed for each destination and each report D7412GV2 can deny access during armed periods. The group.
Inhaltszusammenfassung zur Seite Nr. 14
D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview 3.3.15 NetCom Functions 3.3.17 Other Features The D6600 NetCom System supports data network D9412GV2 and D7412GV2 Control Panels have many communications. NetCom allows the D6600 receiver to programmable features. Some of the features are listed connect to various network topologies, specifically below. Complete details on all features are in the Ethernet and token-ring. NetCom also allows this D9412GV2/D7412GV2 Prog
Inhaltszusammenfassung zur Seite Nr. 15
D9412GV2/D7412GV2 | Operation and Installation Guide | 4.0 Installation . 4.2 Enclosure Options 4.0 Installation Mount the control panel assembly in any of the Bosch Security Systems enclosures listed: 4.1 Installation Preparation • D8103 Universal Enclosure (tan) This section contains a general installation procedure • D8109 Fire Enclosure (red) and refers to other sections of the document for • D8108A Attack Resistant Enclosure (tan) detailed instructions. Refer to the D9412GV2/D7
Inhaltszusammenfassung zur Seite Nr. 16
D9412GV2/D7412GV2 | Operation and Installation Guide | 4.0 Installation • If a ground fault condition occurs, the keypads 4.4 Installing the Control Panel display SERVC GND FAULT and the control panel 1. Place the control panel over the inside back of the transmits a GROUND FAULT TROUBLE, AREA 1 enclosure, aligning the large rectangular openings 2 (Modem IIIa format only). of the mounting skirt with the mounting hooks of When the control panel recognizes that the ground the enclosur
Inhaltszusammenfassung zur Seite Nr. 17
D9412GV2/D7412GV2 | Operation and Installation Guide | 4.0 Installation . Releasing the reset pin from the closed position resets 4.5.3 Enabling Ground Fault Detection the control panel. The control panel resets all its timers, To configure the D9412GV2 and D7412GV2 Control counters, indexes, and buffers. Any points that restore Panels to enable ground fault detection: after a reset do not generate Restoral Reports. 1. Set the silent relay in Area 5 to any value from 1 If the reset pin
Inhaltszusammenfassung zur Seite Nr. 18
D9412GV2/D7412GV2 | Operation and Installation Guide | 4.0 Installation 4.6.3 Installing Modules and Relays 4.6 Completing the Installation 1. Power down the unit by unplugging the If not already complete, make the earth ground transformer and disconnecting the battery. connection to Terminal 10 and lock the reset pin in the closed position. Always power down the unit when installing 4.6.1 Charging the Battery modules or relays, or when making wiring connections to the control pane
Inhaltszusammenfassung zur Seite Nr. 19
D9412GV2/D7412GV2 | Operation and Installation Guide | 4.0 Installation . 4.7 Programming the Control Panel If the control panel is not already programmed, review the D9412GV2/D7412GV2 Program Entry Guide (P/N: F01U003636). Ensure that all accessory modules for desired features are available for installation. Place the reset pin in the locked position to copy or send information to and from the control panel. Use the D5200 Programmer or the RPS to load a custom program into the contro
Inhaltszusammenfassung zur Seite Nr. 20
D9412GV2/D7412GV2 | Operation and Installation Guide | 5.0 Power Supply 5. Secure the transformer to the outlet with the screw provided. 5.0 Power Supply D8004 Transformer Enclosure Required for Fire 5.1 Primary Power Terminals 1 and 2 Systems: Use the D8004 Transformer Enclosure for the D1640 Transformer in fire and combined fire and 5.1.1 Primary (AC) Power Circuit burglary applications. The primary source is a 16.5 VAC, 40 VA, internally- Check with the Authority Having Jurisdic