The Professional Restaurant Gas
Tandoor
Use and Installation Guide
Models:
DCS-CGT
Inhaltszusammenfassung zur Seite Nr. 2
A Message To Our Customers “CONGRATULATIONS”. You have selected the World’s First UL, CUL, and NSF tested and Certified Restaurant Quality Ceramic Interior Gas Operated Tandoor. Because of this appliance’s unique features we have developed this Use and Installation Guide. It contains valuable information on how to properly operate and maintain your new appliance for years of safe and enjoyable operation. To help serve you better, please fill out and return the Ownership Registration Card and
Inhaltszusammenfassung zur Seite Nr. 3
Introduction/Safety Precautions Thank you for choosing your new Dynamic Cooking Systems Professional Restaurant Gas Tandoor. Our prod- ucts are designed to be safe and reliable when properly cared for and used reasonably. Periodical inspections are recommended by your service agency or dealer. Installation, maintenance, and repairs should be performed by your local authorized service agency. This equipment is for commercial use by trained professionals familiar with Tandoor cooking equipment
Inhaltszusammenfassung zur Seite Nr. 4
Fe a t u re s The Professional Tandoor by DCS comes with these standard features. ● Input rating = 70,0000 BTU/HR ● Overall dimensions 34” wide x 36” high x 35” deep. ● 1 inch thick ceramic bowl to retain heat longer and more evenly. ● All stainless steel exterior. ● Ceramic bowl preheats to 800F in approx. 45 minutes. ● Two heavy round cast iron burners each controlled separately for complete temperature control. ● 100% safety shut off standing pilot. (Main burner shuts off if pilot goes out).
Inhaltszusammenfassung zur Seite Nr. 5
Medallion Series Specification s EXTERIOR DIMENSION ● WIDTH: 34” (864mm) ● HEIGHT (w/6” legs): 36” (915mm) ● DEPTH: 35” (889mm) SHIPPING WEIGHT DIMENSIONS ● MINIMUM ENTRY CLEARANCE: Crated 39 1/4” - Uncrated 34 1/4” GAS REQUIREMENTS ● MANIFOLD PRESSURE: 6” W.C. Natural Gas - 10” W.C. Propane Gas ● MANIFOLD SIZE: 3/4” NPT ● INPUT RATING 70,000 BTU / HR CLEARANCES ● NON-COMBUSTIBLE: Sides 0” - Back 0” ● COMBUSTIBLE: Sides 6” - Back 6” FIG.01 Top View 3” 12.5 ” 35 ” 18 ” FIG.02 Front View
Inhaltszusammenfassung zur Seite Nr. 6
Pre-Installation Important: Safe and satisfactory operation of your equipment depends on its proper installation. Installation must conform to local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-1988 (or latest edition). The Canadian CAN/CGA-B149.1 Natural Gas Installation code, and CAN / CGA B149.2 Propane installation code. NOTE: Installation of any gas fired equipment should be perf0rmed by a licensed plumber. A manual gas shut off valve must be ins
Inhaltszusammenfassung zur Seite Nr. 7
Installing The Tandoor UNPACKING Check that the container is upright. Use outward prying no hammering to remove the carton. Check the Tandoor for visible damage. If such damage has occurred, do not refuse shipment, but contact the carrier and file the appropriate freight claims. Do not contact the factory, as responsibility for shipping damage is between the carrier and dealer or end user. Remove, unwrap, and temporarily set aside any accessories shipped with the Tandoor. POSITIONING Do not
Inhaltszusammenfassung zur Seite Nr. 8
Installing The Tandoor PRESSURE REGULATING The Tandoor and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1/2 psig. The Tandoor must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping at pressures equal or less than 1/2 psig. Tandoor must have a pressure regulator on the incoming service line f
Inhaltszusammenfassung zur Seite Nr. 9
Initial Start-up / Operation PLACEMENT OF LAVA ROCK Place a layer of lava rock on the stainless steel pan located directly above the burners. PILOT & MAIN BURNERS All Tandoors are tested and adjusted before leaving the factory, effectively matching them to sea level condi- tions. Adjustments to assure proper operation may be necessary on installation to meet local conditions; low gas pres- sure, differences in altitude, variations in gas characteristics, possible problems caused by rough handli
Inhaltszusammenfassung zur Seite Nr. 10
Cleaning and Maintenance GENERAL New units are wiped clean at the factory to remove any visible signs of dirt, oil, grease remaining from the man- ufacturing process. They should be washed thoroughly with hot soapy water to remove any installation dust or debris before being used for food preparation. Also wash any accessories shipped with the Tandoor. Any piece of equipment works better and last longer when maintained properly and kept clean. Tandoor is no exception. The Tandoor must be kept
Inhaltszusammenfassung zur Seite Nr. 11
Medallion Series Parts List ITEM DESCRIPTION PART NO. 11 Crumb Tray Slide L/H 20065-02 12 Front Panel 20068 13 Body Side Panel R/H 20071-01 1Manual Valve 3/8 13034 14 Body Side Panel L/H 20071-02 2 Knob Chrome 14020-02 15 Back Panel 20072 3 Ceramic Bowl 14272 16 Lava Rock Bag 10312 4 Logo DCS Medallion Series 17301 17 Orifice 13005-05 5 Leg Assembly 18036-1 18 Regulator 13006-5 6 Lid W/Assembly 20047 19 Thermocouple 13007-01 7 Lid Handle 20049 20 12 Burner Assembly 20078 8 Manifold W/
Inhaltszusammenfassung zur Seite Nr. 12
Troubl e shooting These troubleshooting procedures must be carried out only by a factory authorized agency for warranty repair. The problems and possible solutions given below cover those most commonly encountered. PILOT BURNER MALFUNCTION Pilot will not ignite; no evidence of gas at pilot burner: ● Check that the gas valve is open and gas is present at the valve. ● Check pilot burner adjustment. Adjust the pilot flame to extend above the top of the pilot. Pilot adjustment screw is located on
Inhaltszusammenfassung zur Seite Nr. 13
War ranty For warranty service, contact your local DCS authorized service agency. Provide him with the Model Number, Serial Number, and date of installation, and a brief description of the problem. If you need assistance in locating the authorized service agency in your area please contact our DCS Customer Service Department for an authorized service agent near you, our number is (888) 281-5698. Your satisfaction is of the utmost importance to us. If a problem cannot be resolved to your satisfa
Inhaltszusammenfassung zur Seite Nr. 14
As product improvement is an ongoing process at DCS, we reserve the right to change specifications or design without notice. 5800 Skylab Road, Huntington Beach, CA. 92647 Tel: (714) 372-7000 Part No. 17331 Fax: (714) 372-7001 Parts/Customer Service (888) 281-5698 Litho in USA 08/2000