Inhaltszusammenfassung zur Seite Nr. 1
The Chamberlain Group, Inc.
845 Larch Avenue
Elmhurst, Illinois 60126-1196
www.liftmaster.com
®
GARAGE DOOR OPENER
Model 3280M 1/2HP
3280M-267 1/2HP
For Residential Use Only
Owner’s Manual
■ Please read this manual and the enclosed safety materials carefully!
■ Fasten the manual near the garage door after installation.
®
■ The door WILL NOT CLOSE unless the Protector System is connected and
properly aligned.
■ Periodic checks of the opener are required to ensure safe operation.
■ Th
Inhaltszusammenfassung zur Seite Nr. 2
TABLE OF CONTENTS Adjustment 23-25 Introduction 2-5 Adjust the travel limits . . . . . . . . . . . . . . . . . . . . . . . . . .23 Safety symbol and signal word review. . . . . . . . . . . . . . . 2 Adjust the force . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Preparing your garage door . . . . . . . . . . . . . . . . . . . . . . . 3 Test the safety reversal system . . . . . . . . . . . . . . . . . . .25 Tools needed . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inhaltszusammenfassung zur Seite Nr. 3
1 Preparing your garage door Before you begin: To prevent possible SERIOUS INJURY OR DEATH: � Disable locks. • ALWAYS call a trained door systems technician if garage � Remove any ropes connected to garage door. door binds, sticks, or is out of balance. An unbalanced garage door may not reverse when required. � Complete the following test to make sure your garage • NEVER try to loosen, move or adjust garage door, door door is balanced and is not sticking or binding: springs, cables, pu
Inhaltszusammenfassung zur Seite Nr. 4
— — — — — — — — Planning Identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be required. You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener. FINISHED CEILING SECTIONAL DOOR INSTALLATION Support bracket & fastening hardware is required. Horizontal and vertical reinforcement See pag
Inhaltszusammenfassung zur Seite Nr. 5
Carton Inventory Your garage door opener is packaged in two cartons purchased. If anything is missing, carefully check the which contain the motor unit and all parts illustrated packing material. Parts may be stuck in the foam. below. Accessories will depend on the model Hardware for installation is also listed below. Belt Cap Retainer ® SECURITY✚ Remote Control 3-Button Remote Control Transmitter Visor Clip Models 3280M (1) 3280M-267 (2) Styrofoam Multi-Function Door Control Panel Belt Moto
Inhaltszusammenfassung zur Seite Nr. 6
ASSEMBLY STEP 1 Attach the Rail to the Motor Unit To avoid SERIOUS damage to opener, ONLY use bolts/ fasteners mounted in top of motor unit. To avoid installation difficulties, do not run the garage door opener until instructed to do so. � Remove the two washered bolts mounted in top of motor unit. � Align rail and styrofoam over sprocket. Cut tape from rail, belt and styrofoam. USE ONLY THIS TYPE AND SIZE � REMOVE STYROFOAM. BOLT � Insert washered bolts through the rail into the motor
Inhaltszusammenfassung zur Seite Nr. 7
ASSEMBLY STEP 3 Attach the Belt Cap Retainer To avoid possible SERIOUS INJURY to fingers from moving garage door opener: � Position the belt cap retainer over the motor unit • ALWAYS keep hand clear of sprocket while operating opener. sprocket so the two holes in cap align with the two holes • Securely attach sprocket cover BEFORE operating. in mounting plate. Attach with 8x3/8" hex screws provided. You have now finished assembling your garage door opener. Please read the following warnin
Inhaltszusammenfassung zur Seite Nr. 8
Unfinished OPTIONAL INSTALLATION STEP 1 Ceiling CEILING Determine the Header Bracket Location MOUNT FOR HEADER BRACKET Header Wall 2x4 Vertical Centerline To prevent possible SERIOUS INJURY or DEATH: of Garage Door • Header bracket MUST be RIGIDLY fastened to structural 2x4 Structural support on header wall or ceiling, otherwise garage door Supports might not reverse when required. DO NOT install header bracket over drywall. • Concrete anchors MUST be used if mounting header bracket or 2x4
Inhaltszusammenfassung zur Seite Nr. 9
INSTALLATION STEP 2 Install the Header Bracket Wall Mounting Holes You can attach the header bracket either to the wall above CEILING MOUNT ONLY the garage door, or to the ceiling. Follow the instructions The nail hole is for positioning only. which will work best for your particular requirements. Do You must use lag screws UP not install the header bracket over drywall. If installing to mount the header bracket. into masonry, use concrete anchors (not provided). WALL HEADER BRACKET INSTALLA
Inhaltszusammenfassung zur Seite Nr. 10
INSTALLATION STEP 3 Attach the Rail to the Header Bracket � Position the opener on the garage floor below the header bracket. Use packing material as a protective base. NOTE: If the door spring is in the way you’ll need help. Have someone hold the opener securely on a temporary support to allow the rail to clear the spring. Header Wall � Position the rail bracket against the header bracket. � Align the bracket holes and join with a clevis pin Header Bracket as shown. � Insert a ring fas
Inhaltszusammenfassung zur Seite Nr. 11
INSTALLATION STEP 4 Position the Opener To prevent damage to garage door, rest garage door opener rail on 2x4 placed on top section of door. Follow instructions which apply to your door type as illustrated. SECTIONAL DOOR OR ONE-PIECE DOOR WITH TRACK A 2x4 laid flat is convenient for setting an ideal Rail door-to-rail distance. � Remove foam packaging. � Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough. 2x4 is used to determine Door the
Inhaltszusammenfassung zur Seite Nr. 12
INSTALLATION STEP 5 Hang the Opener To avoid possible SERIOUS INJURY from a falling garage door opener, fasten it SECURELY to structural supports of the Three representative installations are shown. Yours may garage. Concrete anchors MUST be used if installing any be different. Hanging brackets should be angled (Figure 1) brackets into masonry. to provide rigid support. On finished ceilings (Figure 2 and Figure 3), attach a sturdy metal bracket to structural supports before installing the
Inhaltszusammenfassung zur Seite Nr. 13
LIGHT LIGHT LIGHT INSTALLATION STEP 6 Install the Door Control To prevent possible SERIOUS INJURY or DEATH from Locate door control within sight of door at a minimum electrocution: height of 5 feet (1.5 m) where small children cannot reach, • Be sure power is not connected BEFORE installing door and away from moving parts of door and door hardware. control. The installation surface must be smooth and flat. If • Connect ONLY to 24 VOLT low voltage wires. installing into drywall (Figure 1)
Inhaltszusammenfassung zur Seite Nr. 14
NOTICE INSTALLATION STEP 7 Install the Light To prevent possible OVERHEATING of the endpanel or light socket: � Press the release tabs on both sides of lens. Gently • DO NOT use short neck or specialty light bulbs. rotate lens back and downward until the lens hinge is in • DO NOT use halogen bulbs. Use ONLY incandescent. the fully open position. Do not remove the lens. To prevent damage to the opener: � Install a 100 watt maximum light bulb in each socket. • DO NOT use bulbs larger than
Inhaltszusammenfassung zur Seite Nr. 15
INSTALLATION STEP 9 Electrical Requirements To prevent possible SERIOUS INJURY or DEATH from electrocution or fire: To avoid installation difficulties, do not run the opener • Be sure power is not connected to the opener, and at this time. disconnect power to circuit BEFORE removing cover to To reduce the risk of electric shock, your garage door establish permanent wiring connection. opener has a grounding type plug with a third grounding • Garage door installation and wiring MUST be in
Inhaltszusammenfassung zur Seite Nr. 16
INSTALLATION STEP 10 ® Install The Protector System Be sure power is not connected to the garage door opener BEFORE installing the safety reversing sensor. The safety reversing sensor must be connected and To prevent SERIOUS INJURY or DEATH from a closing aligned correctly before the garage door opener will garage door: move in the down direction. • Correctly connect and align the safety reversing sensor. IMPORTANT INFORMATION ABOUT This required safety device MUST NOT be disabled.
Inhaltszusammenfassung zur Seite Nr. 17
INSTALLING THE BRACKETS Be sure power to the opener is disconnected. Install Figure 1 DOOR TRACK MOUNT (RIGHT SIDE) and align the brackets so the sensors will face each other across the garage door, with the beam no higher than 6" (15 cm) above the floor. They may be installed in one of Door Track three ways, as follows. Lip Garage door track installation (preferred): Indicator � Slip the curved arms over the rounded edge of each Light door track, with the curved arms facing the door. Sna
Inhaltszusammenfassung zur Seite Nr. 18
MOUNTING AND WIRING THE SAFETY REVERSING Figure 5 SENSORS Wing Nut 1/4"-20 � Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket Carriage Bolt extension (Figure 5). 1/4"-20x1/2" Lens � Finger tighten the wing nuts. � Run the wires from both sensors to the opener. Use TROUBLESHOOTING THE SAFETY REVERSING insulated staples
Inhaltszusammenfassung zur Seite Nr. 19
INSTALLATION STEP 11 Fasten the Door Bracket Fiberglass, aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket. Follow instructions which apply to your door type as Contact your door manufacturer for reinforcement kit. illustrated below or on the following page. A horizontal reinforcement brace should be long enough to be secured to two or three vertical supports. A vertical reinforcement brace should cover Header the height of the top p
Inhaltszusammenfassung zur Seite Nr. 20
ONE-PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page. They apply to one-piece doors also. � Center the door bracket on the top of the door, in line with the header bracket as shown. Mark either the left and right, or the top and bottom holes. � Metal Doors: Drill 3/16" pilot holes and fasten the bracket with the 1/4"-14x5/8" self-threading screws HARDWARE SHOWN ACTUAL SIZE provided. � Wood Doors: Drill 5/16" holes and use 5/16"x