Inhaltszusammenfassung zur Seite Nr. 1
F300 Electronic Air Cleaner
PRODUCT DATA
FEATURES
Media postfilters (optional) provide enhanced filtration.
Available in five sizes to fit most ducts; adapts to
airflow from either side.
3
Capacity varies from 1000 cfm (2040 m /hr) to 2000 cfm
3
(3400 m /hr), depending on size.
Solid state power supply is self-regulating and
maintains peak efficiency during a wide range of cell
dirt loading conditions.
Low pressure drop.
Optional W8600F Air Cleaner Monitor indicates air
cleaner
Inhaltszusammenfassung zur Seite Nr. 2
F300 ELECTRONIC AIR CLEANER SPECIFICATIONS IMPORTANT Table 1. Current Draw. The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifica- Size Max Current (A) No. tions. This product is tested and calibrated under in. mm Cells 120V 220/240V closely controlled conditions, and some minor differ- ences in performance can be expected if those con- 16 x 25 406 x 635 2 0.4 0.2 ditions are changed. 20 x
Inhaltszusammenfassung zur Seite Nr. 3
F300 ELECTRONIC AIR CLEANER AIR CLEANER EFFICIENCY AND PRESSURE DROP AT VARIOUS AIRFLOW RATES. WITHOUT POST FILTERS .25 (62.2) 16 x 20 in. (406 x 508 mm) .20 (49.7) 20 x 25 in. 16 x 25 in. .15 (508 x 635 mm) (406 x 635 mm) (37.3) 20 x 20 in. (508 x 508 mm) 20 x 12-1/2 in. .10 (508 x 318 mm) (24.9) 4 .05 (12.4) 1 2 3 0 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 (680) (850) (1020) (1190) (1360) (1530) (1700) (1870) (2040) (2210) (2380) (2550) (2720) (2890) (3060
Inhaltszusammenfassung zur Seite Nr. 4
F300 ELECTRONIC AIR CLEANER Accessories: Repair Parts: 203365A Conversion Kit for changing 120V, 60 Hz power See Replacement Parts/Exploded View section. supply to 240V, 60 Hz or 220/240V, 50 Hz. W8600F Air Cleaner Monitor. W8600A AIRWATCH Indicator. Table 3. Shipping and Installed Weight. Weight 16 x 20 in. 16 x 25 in. 20 x 12-1/2 in. 20x 20 in. 20 x 25 in. (406 x 508 mm) (406 x 635 mm) (508 x 318 mm) (508x 508 mm) (508 x 635 mm) Item lb kg lb kg lb kg lb kg lb kg Electronic Cell 5 2.25 6 2.7
Inhaltszusammenfassung zur Seite Nr. 5
F300 ELECTRONIC AIR CLEANER 3 6 8 (162) ELECTRONIC AIR CLEANER DIM. E (SEE TABLE) DIM. B DIM. A (SEE TABLE) (SEE TABLE) 7 7 8 5 3 8 (22) DIM. C (SEE TABLE) 6 8 4 (22) (16) (172) DIM. D (SEE TABLE) DIM. D DIM. E F50F SIZE DIM. A DIM. B DIM. C IN. MM IN. MM IN. MM IN. MM IN. MM IN. MM 16 X 25 406 X 635 14 7/16 367 16 3/16 411 23 1/4 591 25 1/2 2 3/4 648 70 16 X 20 406 X 508 14 7/16 367 16 3/16 411 18 1/4 457 20 1/2 2 3/4 521 70 20 X 25 508 X 635 18 7/16 468 20 3/16 513 23 1/4 591 25 1/2 2 3/4 648
Inhaltszusammenfassung zur Seite Nr. 6
F300 ELECTRONIC AIR CLEANER Applications with a Humidifier Choose Location An evaporative humidifier can be mounted upstream from the Choose a location that is readily accessible for regular air cleaner. An atomizing humidifier should be mounted inspection and cleaning. Allow at least 13 in. (330 mm) in front downstream from the air cleaner, even though hard water salts of the access door for removing the metal mesh prefilter, media will be blown into the living space and deposited as dust. I
Inhaltszusammenfassung zur Seite Nr. 7
F300 ELECTRONIC AIR CLEANER A B D C E F G M19777 Fig. 3. Mounting positions with variety of furnace installations. Determine Duct Design Requirements The air cleaner is adaptable to all new or existing forced air CHANGE DUCT SIZE GRADUALLY TO MINIMIZE TURBULENCE. heating, cooling and ventilating systems used in residential 20 DEGREE EXPANSION PER SIDE PER applications. Transitions, turning vanes, or offsets may be FITTING (4 in. PER LINEAR FOOT needed in some applications for effective oper
Inhaltszusammenfassung zur Seite Nr. 8
EL ECTRO NIC AIR CLEANER F300 ELECTRONIC AIR CLEANER Offsets Clean Blower Compartment If the duct connection to the furnace in a side installation allows ! Remove and discard the existing furnace filter. less than 7 in. (178 mm) for mounting the air cleaner cabinet, ! Thoroughly clean the blower compartment. add an offset to the elbow. See Fig. 5. ! If possible, power vacuum the ductwork to remove accumulated dust in an existing home, or construction dirt in a new home. The electronic air cl
Inhaltszusammenfassung zur Seite Nr. 9
F300 ELECTRONIC AIR CLEANER Install Turning Vanes ! Mount turning vanes inside the elbow or angle fitting that is directly against the air cleaner cabinet. See Fig. 7. Fasten Cabinet To Ductwork DOWNSTREAM AIRFLOW ! Install a transition when the opening in the air cleaner cabinet and the duct are different sizes. See Fig. 4. CELL KEY CELL ! Fasten the other side of the cabinet to the elbow using SCREW KEY CELL KEY sheet metal screws, rivets, or slip joints as appropriate. If drilling holes,
Inhaltszusammenfassung zur Seite Nr. 10
F300 ELECTRONIC AIR CLEANER Assure all wiring complies with local codes and ordinances. Reassemble Air Cleaner The line voltage power source must match the voltage and ! Insert the electronic cells with the gray contact board toward frequency printed on the label inside the access door. the power supply and the airflow arrow pointing When the System fan comes on, the Air Flow Switch (AFS) downstream. If the cell does not slide easily into the cabinet, senses the negative pressure in t
Inhaltszusammenfassung zur Seite Nr. 11
F300 ELECTRONIC AIR CLEANER 1. Open access door. OPERATION 2. Remove and retain the two screws from the front of the power box and the two screws from the sides of the Large particles (lint, hair) are caught by the prefilter. As the power box. See Fig. 11. dirty air passes through the intense high voltage electric field 3. In the power box, remove and retain two wire nuts that surrounding the ionizer wires, all particles are given an connect the line cord leads to the power box wiring. ele
Inhaltszusammenfassung zur Seite Nr. 12
F300 ELECTRONIC AIR CLEANER NOTE: To let the heating or air conditioning system operate Check Air Cleaner Operation normally while the cells are being washed, simply turn With all components in place, turn on air cleaner switch and off the air cleaner switch. energize system blower. Check following points of operation: 1. The neon light next to the On-Off switch is on. The neon IMPORTANT light shows that the air cleaner is energized and the high Vacuum the prefilter or brush or soak it in a
Inhaltszusammenfassung zur Seite Nr. 13
F300 ELECTRONIC AIR CLEANER 7. Wipe ionizer wires and contact board on end of cell using Washing Cells in a Container your thumb and forefinger with a small, damp cloth. Washing Cells at the Car Wash CAUTION Use the hand sprayer at a coin-operated do-it-yourself car Hazardous Chemical. wash to clean the cells. Hold the nozzle at least two feet away Can cause personal injury. from the unit to avoid damage (such as broken ionizer wires or Do not splash detergent solution in eyes. Wear rubber
Inhaltszusammenfassung zur Seite Nr. 14
F300 ELECTRONIC AIR CLEANER Replacing Ionizer Wires COLLECTOR Broken or bent ionizer wires can cause an electrical short to TERMINAL ground, often resulting in visible arcing or sparking. Do not use IONIZER cells until broken wires are removed. Cells can be used TERMINAL temporarily with one wire missing, but replace the wire as soon COLLECTOR as possible. TERMINAL Replacement wires are supplied cut to length with eyelets on both ends for easy installation. See Parts and Accessories Not I
Inhaltszusammenfassung zur Seite Nr. 15
F300 ELECTRONIC AIR CLEANER a. Unplug or disconnect power supply to the air cleaner. b. Open the access door. WARNING c. Remove the power box cover. See Fig.17. Electric Shock Hazard. d. Locate J5 shorting bar on the power supply. See Fig. Can cause personal injury. 18. Remove the shorting bar and reinstall on only Only a trained service technician should perform the one pin. following procedure. NOTE: The ozone will be reduced, but the shorting bar is 2. Move J5 shorting bar. This will red
Inhaltszusammenfassung zur Seite Nr. 16
F300 ELECTRONIC AIR CLEANER P3 J5 SHUNT P4 IN OZONE REDUCTION POSITION E5 E6 J4 J5 IN NORMAL E4 E3 POSITION E2 E1 J3 P2 P1 M15099 Fig. 18. Move J5 shorting bar to reduce ozone production about 20 to 25 percent. 68-0240EF-5 16 J1 J5
Inhaltszusammenfassung zur Seite Nr. 17
F300 ELECTRONIC AIR CLEANER REPLACEMENT PARTS (TABLE 4)/EXPLODED VIEW (FIG. 19) Table 4. Replacement Parts. Nominal Return Air Opening 16 x 20 in. 16 x 25 in. 20 x 12-1/2 in. 20 x 20 in. 20 x 25 in. No. Description (406 x 508 mm) (406 x 635 mm) (508 x 318mm) (508 x 508 mm) (508 x 635 mm) 1 F300 Door includes No. 2 32007528-003 32007528-003 N/A 32007528-002 32007528-002 2 Test Button Assembly 137980A (1) 137980A (1) 137980A (1) 137980A (1) 137980A (1) 3 Electronic Cell FC37A1114 (2) FC37A1130 (
Inhaltszusammenfassung zur Seite Nr. 18
F300 ELECTRONIC AIR CLEANER 10 14 20 17 13 12 7 11 19 8 22 21 6 5 4 3 2 1 M18846D Fig. 19. F300 Electronic Air Cleaner (2-cell model shown) exploded view of components. Part Numbers are keyed to Parts List. 68-0240EF-5 18
Inhaltszusammenfassung zur Seite Nr. 19
F300 ELECTRONIC AIR CLEANER PARTS AND ACCESSORIES NOT ILLUSTRATED (TABLE 5) Table 5. Parts and Accessories Not Illustrated. Nominal Return Air Opening 16 x 20 in. 16 x 25 in. 20 x 12-1/2 in. 20 x 20 in. 20 x 25 in. Description (406 x 508 mm) (406 x 635 mm) (508 x 318) (508 x 508 mm) (508 x 635 mm) Air Cleaner 32002109-001 32002109-001 32002109-001 32002109-001 32002109-001 Cabinet Gasket Kit Ionizer Wires 136434BA 136434BA 136434AA 136434AA 136434AA (Multiples of 5) Premier White® W8600A1007 W
Inhaltszusammenfassung zur Seite Nr. 20
F300 ELECTRONIC AIR CLEANER SERVICE REMINDER SCHEDULE ELECTRONIC AIR CLEANER WASH REMINDER AND POSTFILTER REPLACEMENT SCHEDULE INSTALLATION DATE: , YEAR JF M A M J J A S O N D M19779 68-0240EF-5 20