Inhaltszusammenfassung zur Seite Nr. 1
Operating Instructions
Touch Panel
Model No. TY-TP42P30K
TY-TP50P30K
TY-TP60P30K
TY-TP65P30K
Before connecting, operating or adjusting this product, please read these instructions completely.
Please keep this manual for future reference.
English
Inhaltszusammenfassung zur Seite Nr. 2
Contents Precautions with regard to setting up ........................2 Operating Conditions .................................................8 Maintenance .............................................................3 Touch Operation ........................................................9 Components .............................................................4 Before Calling for Service ........................................10 Touch Panel Assembly ...........................
Inhaltszusammenfassung zur Seite Nr. 3
Maintenance Setup location Places where the touch panel should not be setup include: • Locations exposed to direct sunlight, and locations near powerful light sources (The equipment is an optical touch panel utilizing infrared rays and may function incorrectly when adversely affected.) • Dusty or humid locations • Locations that may be exposed to impact or vibration • Locations near emissions of chemicals or steam, or locations where contact may be made with chemicals • Locations near sourc
Inhaltszusammenfassung zur Seite Nr. 4
(Check the components and their quantities.) Components Touch panel (1) Mounting bracket A Mounting bracket B (4) (for top side) (2) Mounting screw A (8) Mounting bracket A (for bottom side) (2) Mounting screw B (8) Accessories Operating Instructions USB extension cable (1)CD-ROM (1) (1) • Operating Instructions • Driver software Touch pen (2) Illustrations are conceptual views and may differ in shape from the actual equipment. The specifications of the product a
Inhaltszusammenfassung zur Seite Nr. 5
Touch Panel Assembly Note • Place the touch panel making its front surface face down on a clean cloth or blanket to prevent the front surface of the touch panel from getting scratched or dirty during work. Mounting in horizontal posture Attach the mounting brackets A (for top and bottom sides) to the touch panel with the mounting screws A (2 each). See the gure below for the screw holes of attachment positions. The procedure for vertical posture is the same. Mounting screw A Mounting
Inhaltszusammenfassung zur Seite Nr. 6
Mounting Touch Panel Notes • Two or more people are always required for mounting. • Never mount the main device in the way that is overlapped from above the touch panel while the touch panel is laid down. Doing so may damage the touch panel. Fit the assembled touch panel from the front side of the main device. 1 Note • There should not be a space between the touch panel and the front surface of main device. The procedure for vertical posture is the same. Mount in the way that t
Inhaltszusammenfassung zur Seite Nr. 7
4 Referring to the alignment mark shown in the figure below, adjust the position seeing from the front so that the touch panel does not lean to one side. End of the screen Touch panel alignment mark Power lamp window 5 After adjusting the position, completely tighten the screws which were temporarily fixed. • Note that tightening the screws too tight may deform the bracket. Notes • There should not be a space between the touch panel and the front surface of the main device. • Con
Inhaltszusammenfassung zur Seite Nr. 8
Connection with Computer USB connector type A USB connector type A (Female) (Male) Connect to the Touch panel USB port on your computer. Computer Main device USB connector type A To connect to your computer, (Male) see the instruction manual of the main device. Caution • If the infrared transmissive part on the screen is shaded by your ngers or other things when connecting the USB extension cable, that may be detected as a failure during initialization and, if no corrective action is tak
Inhaltszusammenfassung zur Seite Nr. 9
Touch Operation Use the supplied touch pen. The touch operations are different depending on the OS used. Dual touch is not possible on Windows XP and Vista. Windows Function XP/ 7 Vista Single tap Applicable Applicable Functions as a left click of mouse. Functions as a double-click by quickly touching twice. The pen or a finger should be set apart enough from the panel Double tap Applicable Applicable window before the second touch is made. If the distance is not enough, the double tap may no
Inhaltszusammenfassung zur Seite Nr. 10
Before Calling for Service If you think the touch panel is broken or if it is not operating correctly, check the following before calling for service. When using Windows XP or Vista, refer also to “Troubleshooting” of the installation manual of the touch panel included in the supplied CD-ROM. For Windows XP, Vista and 7 *1 Windows 7 only Problem Check point Action to take Page Check that the USB cable is connected. If using a USB hub, check that the power is supplied 8 from the
Inhaltszusammenfassung zur Seite Nr. 11
Problem Check point Action to take Page This equipment is a touch panel using infrared rays. Incident light containing infrared rays may hinder operation of the touch panel. Sunlight: It is not a problem as long as the infrared transmissive part of the touch panel is not directly exposed to sunlight. Fluorescent light: It can be a problem because some Response is Are strong light sources or types of fluorescent light (particularly inverter type) lost during devices that use infrared – pr
Inhaltszusammenfassung zur Seite Nr. 12
Problem Check point Action to take Page The touched Perform calibration in “General” of “Tablet PC Settings” Has calibration been point is of the Control Panel. For more information, see the – performed? *1 help information of Windows. displaced If the touch panel was removed and mounted again, the mounting position may not be the same as the previous one, and thus the touching position and cursor position may not match. If the touch panel was removed, be sure to perform calibration. For
Inhaltszusammenfassung zur Seite Nr. 13
Speci cations Model Number TY-TP42P30K TY-TP50P30K TY-TP60P30K TY-TP65P30K Type Touch Panel Voltage +5V DC±10% Electric current +5V DC Max. 500 mA Supply method From USB bus Detection system Infrared ray interruption detection 934.1 mm (W) × 1124.1 mm (W) × 1348.1 mm (W) × 1468.1 mm (W) × Panel window 524.1 mm (H) 638.1 mm (H) 766.1 mm (H) 839.1 mm (H) 925 mm (W) × 1105 mm (W) × 1330 mm (W) × 1435 mm (W) × Detection range 520 mm (H) 615 mm (H) 750 mm (H) 805 mm (H) Effective detection range
Inhaltszusammenfassung zur Seite Nr. 14
External Dimensions (Unit: mm) (Unit: mm) External Dimensions Table of external dimensions 42V 50V 60V 65V A 1028.2 1218.2 1442.2 1562.2 A 79.2 B 618.2 732.2 860.2 933.2 *(89) C 621.4 735.4 863.4 936.4 12 47 47 B C * The dimensions may vary depending on the *(89) device to be mounted to or the status of tightening. 79.2 (Mounting in vertical posture) Drawing of Screw Holes • Refer to page 5 for 42V. 123 4 5 6 For 50V Top Bottom 123 4 5 6 34 8 12 56 7 9 For 60V
Inhaltszusammenfassung zur Seite Nr. 15
Customer’s Record The model number and serial number of this product can be found on its bottom side. You should note this serial number in the space provided below and retain this book, plus your purchase receipt, as a permanent record of your purchase to aid in identi cation in the event of theft or loss, and for Warranty Service purposes. Warranty conditions are managed by distributors to meet the standards set by each country. For details, contact your dealer where you made your purchas