Inhaltszusammenfassung zur Seite Nr. 1
Aluminum Electrolytic Capacitor/FA
Radial lead type
Discontinued
Type :
Series: FA A
n Features Endurance :105 C 2000 to 5000h
Smaller than Series HFQ
Low impedance (20 to 40 less volume than
Series HFQ)
n Specification
-55 to + 105 C
Operating Temp. Range
6.3 to 63 V .DC
Rated W.V. range
68 to 15000 μ F
Nominal cap. range
±20 % (120Hz/+20 C)
Capacitance tol.
DC leakage current I < 0.01 CV (μ A) after 2 minutes application of rated working voltage at +20 C.
W.V. 6.3
Inhaltszusammenfassung zur Seite Nr. 2
Aluminum Electrolytic Capacitor/FA n Case size / Impedance / Ripple current Discontinued W.V.(V.DC) 6.3 (0J) 10 (1A) 10 (1A) Ripple current Ripple current Impedance(100kHz) Impedance(100kHz) Capacitance (100kHz) Capacitance (100kHz) (W ) (W ) (+105 C) (+105 C) (f D· L) (μF) (μF) -10 C +20 C (mA) (mA) -10 C +20 C 8 11.5 560 0.234 0.117 555 · 390 0.234 0.117 555 0.170 0.085 730 8 · 15 820Li 680L 0.170 0.085 730 0.130 0.065 995
Inhaltszusammenfassung zur Seite Nr. 3
Aluminum Electrolytic Capacitor/FA Discontinued n Case size / Impedance / Ripple current W.V.(V.DC) 35 (1V) 50 (1H) Ripple current Ripple current Impedance(100kHz) Impedance(100kHz) Capacitance (100kHz) Capacitance (100kHz) (f D· L) (W ) (W ) (+105 C) (+105 C) (μF) (μF) -10 C +20 C (mA) -10 C +20 C (mA) 8 150 0.234 0.117 555 · 11.5 82 0.468 0.234 485 0.170 0.085 730 8 · 15 220Li 120Li 0.310 0.155 635 0.130 0.065 8 · 20 3
Inhaltszusammenfassung zur Seite Nr. 4
Aluminum Electrolytic Capacitor Application Guidelines 1.2 Operating Temperature and Life Expectancy (1) Expected life is affected by operating temperature. Generally, each 10 C reduction in temperature 1. Circuit Design will double the expected life. Use capacitors at Ensure that operational and mounting conditions the lowest possible temperature below the follw the specified conditions detailed in the catalog maximum guaranteed temperature. and specification
Inhaltszusammenfassung zur Seite Nr. 5
Aluminum Electrolytic Capacitor n Typical failure modes and their factors Faliure mode Faliure mechanism (internal phenomenon) Production factor Application factor Overvoltage applied Increase in inter- Increase in Vent operates • • nal temperature internal pressure • Excessive ripple current Capacitance Reduced anode foil reduction capacitance Reverse voltage applied • • • • • • Reduced cathode tan d increase foil capacitance Severe charging-discharging • AC volta
Inhaltszusammenfassung zur Seite Nr. 6
Aluminum Electrolytic Capacitor 1.3 Common Application Conditions to Avoid The vinyl sleeve of the capacitor can be damaged The following misapplication load conditions will if solder passes through a lead hole for cause rapid deterioration to capacitor electrical subsequently processed parts. Special care when parameters. ln addition, rapid heating and gas locating hole positions in proximity to capacitors is generation within the capacitor can occur causing recommen
Inhaltszusammenfassung zur Seite Nr. 7
Aluminum Electrolytic Capacitor (5)Clearance for Case Mounted Pressure 2.Capacitor Handling Techniques Relief Vents 2.1Considerations Before Using Capacitors with case mounted pressure relief vents (1) Capacitors have a finite life. Do not reuse or require sufficient clearance to allow for proper vent recycle capacitors from used equipment. operation. The minimum clearances are dependent (2) Transient recovery voltage may be generated in on capacitor diameters as follows. the
Inhaltszusammenfassung zur Seite Nr. 8
Aluminum Electrolytic Capacitor 2.4 Flow Soldering 2.6Other Soldering Considerations (1) Don not immerse the capacitor body into the Rapid temperature rises during the preheat solder bath as excessive internal pressure could operation and resin bonding operation can cause result. (2) Observe proper soldering conditions (temperature, cracking of the capacitor vinyl sleeve. For heat time, etc.). Do not exceed the specified limits. curing, do not exceed 150 C for a maximum time of (3) Do not allow
Inhaltszusammenfassung zur Seite Nr. 9
Aluminum Electrolytic Capacitor (3) A thorough drying after cleaning is required to 3.2Electrical Precautions remove residual cleaning solvents which may be trapped between the capacitor and the circuit (1) Avoid touching the terminals of the capacitor as board. Avoid drying temperatures which exceed possible electric shock could result. The exposed the maximum rated temperature of the capacitor. aluminium case is not insulated and could also (4) Monitor the contamination levels of the cleaning
Inhaltszusammenfassung zur Seite Nr. 10
Aluminum Electrolytic Capacitor 6.Capacitor Disposal When disposing of capacitors, use one of the following methods. l Incinerate after crushing the capacitor or puncturing the can wall (to prevent explosion due to internal pressure rise). Capacitors should be incinerated at high temperatures to prevent the release of toxic gases such as chlorine from the polyvinyl chloride sleeve, etc. l Dispose of as solid waste. l Local laws may have specific disposal requirements which must be follo