Inhaltszusammenfassung zur Seite Nr. 1
Operations Manual
Operational instructions for Humminbird Legend 1000 Series
including the Legend –1000, 1005, 1000 Deep and 1005 Deep
Inhaltszusammenfassung zur Seite Nr. 2
THANK YOU Thank you for choosing Humminbird®, America's#1 name in fishfinders. Humminbird has built its reputation by designing and manufacturing top-quality, thoroughly reliable marine equipment. Your Humminbird is designed for trouble-free use in even the harshest marine environment. In the unlikely event that your Humminbird does require repairs, we offer an exclusive Service Policy - free of charge during the first year after purchase, and available at a reasonable rate after the one-year pe
Inhaltszusammenfassung zur Seite Nr. 3
TABLE OF CONTENTS Section 1: USING THE LEGEND 1000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Deep Models Additional Performance . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Powering Up the Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Simulator and Feature Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 User Int
Inhaltszusammenfassung zur Seite Nr. 4
USING THE LEGEND 1000 SERIES PERFORMANCE / SIMULATOR / POWERING UP THE UNIT Powering Up the Unit Legend Models 4000 Watts Peak to Peak After installation, turn the LEGEND 1000 SERIES on by momentarily pressing the North International* GAIN knob. An audible chirp sounds as the unit turns on. If the unit detects American 1000 Series Single that the transducer is connected and is in water, the LEGEND 1000 SERIES 160 x 160 pixels 1000 1005 Beam 8 levels grayscale begins to show sonar information on
Inhaltszusammenfassung zur Seite Nr. 5
USING THE LEGEND 1000 SERIES USER INTERFACE / KNOBS / LCD DISPLAY Range Knob USER INTERFACE The RANGE knob adjusts the The LEGEND 1000 SERIES User Interface is depth ranges used on the made up of the following components: display. The RANGE knob has Push ON / OFF knobs and the LCD Display, which in slightly different capabilities in turn is made up of the RTS (Real Time each mode of operation. See Sonar™) and the Chart Windows. MODES OF OPERATION for specific Knobs information. In all modes, Thr
Inhaltszusammenfassung zur Seite Nr. 6
USING THE LEGEND 1000 SERIES REAL TIME SONAR™ / CHART WINDOW The sonar returns received by the LEGEND 1000 SERIES are Fish appear as smaller groupings of sonar returns displayed along the depth range scale in a REAL TIME between the bottom and surface. Often, large fish SONAR™ (RTS) WINDOW and CHART WINDOW. The RTS WINDOW within a structure will show as a strong return within a displays new sonar information within the transducer grouping of smaller returns. When the boat is cone in an expanded,
Inhaltszusammenfassung zur Seite Nr. 7
USING THE LEGEND 1000 SERIES CHART WINDOW / BOTTOMS / FISH APPEARANCE of many gray levels moving across the display at the same depth. Thermoclines always appear above the Thermocline bottom. Slope Second Return Bait fish Fish Arch Partial Fish Sloped Bottoms Arch Bottoms having a large degree of slope also present a Structure unique picture. These generally have a thicker black band representing the bottom directly under the boat. Equal areas of gray above and below the black band Fish Appeara
Inhaltszusammenfassung zur Seite Nr. 8
USING THE LEGEND 1000 SERIES SONAR VIEWS / CONTROL PANELS Note: It is important to remember that sonar cannot distinguish CONTROL PANELS are displayed by using the CONTROL PANEL knob and adjusted by using the RANGE knob. The active between a fish and some other object suspended in the water. CONTROL PANEL consists of three parts: the CONTROL PANEL NAME, Regardless of the object the sonar detects, it has the SETTING INDICATOR, and SETTING READOUT. possibility of being drawn as an arch. The CONTRO
Inhaltszusammenfassung zur Seite Nr. 9
USING THE LEGEND 1000 SERIES MODES OF OPERATION / OPTIMIZING THE DISPLAY In AUTOMATIC mode, the LEGEND 1000 SERIES selects the depth range best suited to keep recent sonar returns visible; however, the depth range can be adjusted to optimize the display for viewing the second return. The display can also be optimized for maximum Adjustment Indicator display resolution, making Optimized Display showing second return it possible to distinguish fish very close together or close Optimizing the Depth
Inhaltszusammenfassung zur Seite Nr. 10
USING THE LEGEND 1000 SERIES BOTTOM LOCK ZOOM MODE / MANUAL MODE Bottom Lock Zoom Mode Manual Mode BTM LOCK (Bottom Lock) MANUAL mode turns off mode tracks the bottom automatic bottom tracking, similarly to Automatic leaving control of the mode; however, the depth range to the user. Both the upper and lower display shows a full range depth ranges can be adjusted to show the bottom, or view on right and a any other desired depth, in greater detail. When first zoomed window on the switched to MANU
Inhaltszusammenfassung zur Seite Nr. 11
USING THE LEGEND 1000 SERIES CHART SPEED / SONAR VIEW / LIGHT / CONTRAST / RTS WINDOW screen. If the depth is deeper or shallower than the ranges Light on the display, the bottom contour will not be visible. LIGHT activates the display backlight and selects the The manual range settings made to the LEGEND 1000 SERIES brightness level. The default to factory settings after the unit is turned off. backlight is manually-controlled except when the unit Chart Speed first powers up. During initial pow
Inhaltszusammenfassung zur Seite Nr. 12
USING THE LEGEND 1000 SERIES SURFACE CLUTTER / WHITE LINE / FILTER / DEPTH ALARM / TEMP ALARM Surface Clutter Filter SURFACE CLUTTER eliminates FILTER (DEEP Models only) most sonar returns turns the filtering near the water surface algorithms on and off. caused by trapped air, boat wakes and Select ON to filter excess sonar noise. Select OFF temperature inversions. Most surface clutter to show the greatest amount of sonar appears on the display because the strongest information. sonar returns co
Inhaltszusammenfassung zur Seite Nr. 13
USING THE LEGEND 1000 SERIES UPPER TEMP / LOWER TEMP / FISH ALARM / FISH SENSITIVITY / FISH ID for and or are feeding zones for fish. Upper and lower one large and one medium fish symbol), or all sizes of temperatures are set depending on the species of fish fish (displayed as one large, one medium, and one being sought. Two basic actions can be selected to small fish symbol). trigger an alarm, either entering inside a temperature The FISH ALARM setting is retained in memory after the 1000 range
Inhaltszusammenfassung zur Seite Nr. 14
MAINTENANCE AND WARRANTY CONTROL PANELS / MAINTENANCE/TROUBLESHOOTING Simulator Language SIMULATOR allows the LEGEND 1000 LANGUAGE (International Models SERIES to operate in simulated only) selects the language for sonar mode. This is useful for text used in the CONTROL PANELS learning the features and functionality of the LEGEND 1000 and for messages. See the LEGEND 1005/1005 DEEP SERIES when not on the water. Settings to Control Specifications for included languages. Panels that are retained i
Inhaltszusammenfassung zur Seite Nr. 15
MAINTENANCE AND WARRANTY TROUBLESHOOTING disconnecting the cable from both the unit and the TROUBLESHOOTING transducer. Also, make sure that the transducer is fully Repairs submerged in water. If the transducer is connected to Do not attempt to repair the LEGEND 1000 SERIES yourself. the unit through a switch, temporarily connect it There are no user-serviceable parts inside, and directly to the unit and try again. If none of these special tools and techniques are required for items identifies a
Inhaltszusammenfassung zur Seite Nr. 16
MAINTENANCE AND WARRANTY TROUBLESHOOTING / WARRANTY / SERVICE POLICY 5. The unit comes on before I press POWER, and won’t turn off. TECHSONIC INDUSTRIES, INC. ONE YEAR Check the transducer cable—if the outer jacket of the cable has been cut LIMITED WARRANTY and the cable is in contact with bare metal, you need to disconnect the We warrant the original retail purchaser that products made by Techsonic cable from the unit, then repair the cut with electrical tape. If there is no Industries have bee
Inhaltszusammenfassung zur Seite Nr. 17
CUSTOMER RESOURCE CENTER SERVICE POLICY / SERVICE PROCEDURES Techsonic Industries Service Policy Returning Your Unit for Service Even though you'll probably never need to take advantage of our Before sending your unit in for repair, please contact the factory, either by incredible service policy, it's good to know that we back our products this phone or by email, to obtain a Repair Authorization Number for your unit. confidently. We do it because you deserve the best. We will make every Please h
Inhaltszusammenfassung zur Seite Nr. 18
SPECIFICATIONS 1000/1005 SPECIFICATIONS 1000 DEEP/1005 DEEP SPECIFICATIONS Operating Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 kHz Operating Frequencies . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/200 kHz Power Output . . . . . . . . . . . . . . . . . . . . . . .4000 Watts (Peak to Peak) Power Output . . . . . . . . . . . . . . . . . . . . . . .4000 Watts (Peak to Peak) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .