Inhaltszusammenfassung zur Seite Nr. 1
DR4300
Circular Chart Recorder
Product Manual
44-01-25-14
12/03
Revision I
Industrial Measurement and Control
Inhaltszusammenfassung zur Seite Nr. 2
DR4300 Circular Chart Recorder Copyright, Notices, and Trademark Printed in U.S.A. – © Copyright 2003 by Honeywell Revision I – December 2003 WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing
Inhaltszusammenfassung zur Seite Nr. 3
About This Document Abstract This manual contains instructions for installation, operation, and troubleshooting of the DR4300 Circular Chart Recorder. References The following list identifies all documents that may be sources of reference for material discussed in this publication. Document Title Doc ID How to Apply Digital Instrumentation in Severe Electrical 51-52-05-01 Noise Environments Modbus® RTU Serial Communications User Manual 51-52-25-66 Modbus® RTU Serial Communication
Inhaltszusammenfassung zur Seite Nr. 4
DR4300 Circular Chart Recorder Symbol Definitions The following table lists those symbols used in this document to denote certain conditions. Symbol Definition This CAUTION symbol on the equipment refers the user to the Product Manual for additional information. This symbol appears next to required information in the manual. WARNING PERSONAL INJURY: Risk of electrical shock. This symbol warns the user of a potential shock hazard where HAZARDOUS LIVE voltages greater than 30 V
Inhaltszusammenfassung zur Seite Nr. 5
Contents 1. OVERVIEW .............................................................................................................. 1 1.1 Introduction .................................................................................................................................. 1 1.2 Model Number Breakdown ..........................................................................................................4 1.3 About This Manual....................................................
Inhaltszusammenfassung zur Seite Nr. 6
DR4300 Circular Chart Recorder 4.2 Operator Interface on Recorder with Display and Keypad......................................................... 72 4.3 Configuration (Recording and Output Set Up)........................................................................... 74 4.3.1 Overview ....................................................................................................................... 74 4.3.2 Configuration Prompts ......................................................
Inhaltszusammenfassung zur Seite Nr. 7
6.1 Overview .................................................................................................................................. 157 6.2 Replacing the Chart .................................................................................................................. 158 6.3 Replacing the Ink Cartridge...................................................................................................... 159 6.4 Maximizing Pen Life ........................................
Inhaltszusammenfassung zur Seite Nr. 8
DR4300 Circular Chart Recorder A. ACCURACY......................................................................................................... 199 A.1 Overview .................................................................................................................................. 199 A.2 Typical Reference Accuracy..................................................................................................... 200 B. AVAILABLE 10-INCH CHARTS ................................
Inhaltszusammenfassung zur Seite Nr. 9
Tables Table 2-1 Operating Limits and Condensed Specifications .......................................................................................12 Table 2-2 Mounting Flush in a New Panel Cutout.....................................................................................................17 Table 2-3 Procedure for Mounting Recorder with NEMA4 or Heavy Duty Door.....................................................18 Table 2-4 Pipe Mounting Procedure.........................
Inhaltszusammenfassung zur Seite Nr. 10
DR4300 Circular Chart Recorder Table 4-33 Procedure for Resetting Totalizer ..........................................................................................................137 Table 4-34 Procedure for Starting Timer .................................................................................................................138 Table 4-35 Procedure for Resetting Limit Controller...............................................................................................139
Inhaltszusammenfassung zur Seite Nr. 11
Figures Figure 1-1 Guide to Manual’s Organization...............................................................................................................10 Figure 2-1 Overall Dimensions ..................................................................................................................................15 Figure 2-2 Plug Locations ..........................................................................................................................................
Inhaltszusammenfassung zur Seite Nr. 12
DR4300 Circular Chart Recorder DR4300 Circular Chart Recorder Product Manual 12/03 xii
Inhaltszusammenfassung zur Seite Nr. 13
Overview 1. Overview 1.1 Introduction Function The DR4300 recorder is a one or two pen microprocessor-based circular chart recorder. The basic DR4301 (one pen) and DR4302 (two pen) recorders provide reliable, convenient pen-drawn analog traces on preprinted 10 inch (250 mm) charts. Both the chart and the pens are driven by stepper motors controlled by the microprocessor. Chart speed and range are configurable. The basic recorder is also available in CE models DR4321 (one pen) and DR43
Inhaltszusammenfassung zur Seite Nr. 14
DR4300 Circular Chart Recorder Communications The Modbus communication option permits configuration of the unit and monitoring of process variables over a standard multi-drop serial communications link. Relay outputs for control and alarms The models with display and keypad are available with output relays, two for each pen channel. These relays can be wired for Normally Open (NO) and Normally Closed (NC) terminals. ON-OFF control can be performed using one relay (relay simplex control)
Inhaltszusammenfassung zur Seite Nr. 15
Overview The six keys are used to select the real time value to be displayed, and to select set up parameters and their values during configuration. The display and keypad are behind the door, protecting them from dirt. A supplementary external keypad is also available. For more information about the operator interface on models having a display and keypad, see Subsection 4.2. Configuration The models without a display are configured with two switchbanks: one for configuration, the o
Inhaltszusammenfassung zur Seite Nr. 16
DR4300 Circular Chart Recorder 1.2 Model Number Breakdown Introduction The model number breakdown is presented in the tables that follow. Note that not all options are available with all recorders. Check the “Availability” column for each model. A star ( ) in the Availability column means unrestricted availability of the feature for that model. N/A indicates the feature is not available for that model. A letter in the Availability column denotes restricted availability. The meaning of eac
Inhaltszusammenfassung zur Seite Nr. 17
Overview Model Number Table I - OUTPUT Description Model No. Availability 4301 4302 4311 4312 4321 4322 4331 4332 Pen One None 0 _ _ _ 2 Outputs (Alarm/On-Off Control) 2 _ _ _ N/A N/A d d 1 PID Control with Accutune II (see Note 1) 3 _ _ _ N/A N/A d d 1 PID Control/Setpoint Program/Timer(see Note 1) 4 _ _ _ N/A N/A d d 2 Outputs (Alarm 1 and Timer) 5 _ _ _ N/A N/A d d 4 to 20 mA Retransmission Output (see Note 4) A _ _ _ N/A N/A d d FM Approved Limit Control F _
Inhaltszusammenfassung zur Seite Nr. 18
DR4300 Circular Chart Recorder Model Number Table II - INSTRUMENT OPTIONS Description Model No. Availability 4301 4302 4311 4312 4321 4322 4331 4332 Door Options Gray Door G _ _ _ _ Blue Door B _ _ _ _ Gray Door with External Keypad H _ _ _ _ N/A N/A Blue Door with External Keypad C _ _ _ _ N/A N/A Black Door K _ _ _ _ Black Door with External Keypad L _ _ _ _ N/A N/A SST Door R _ _ _ _ NEMA 4 SST Door S _ _ _ _ Standard Latch _ 0 _
Inhaltszusammenfassung zur Seite Nr. 19
Overview Model Number Table III - PEN 1 OPTIONS Description Model No. Availability 4301 4302 4311 4312 4321 4322 4331 4332 No Digital Inputs 0 _ _ _ Digital Inputs (See Note 3) D _ _ _ N/A N/A f g None _ 0 _ _ No Totalizer Function _ _ 0 _ Totalizer _ _ T _ N/A N/A h h Future _ _ _ 0 Model Number Table IV - PEN 2 OPTIONS Description Model No. Availability 4301 4302 4311 4312 4321 4322 4331 4332 No Digital Inputs 0 _ _ _ Digital Inputs (See Note
Inhaltszusammenfassung zur Seite Nr. 20
DR4300 Circular Chart Recorder NOTE 1: PID control options include current output plus two discrete outputs for alarms. If ON-OFF or time-proportioned simplex control is used, only one discrete output is available for an alarm. Time-proportioned duplex control requires the use of both outputs and therefore no relay outputs are available for alarms on that pen channel. Accutune II tuning is a standard feature with PID control options. NOTE 2: Customer must supply the input actuation and ra