Inhaltszusammenfassung zur Seite Nr. 1
Administrator’s Guide
and
Operating Instructions
Real Time Digital Video Recorder
eDR1680 Series
V 1.0
1
Inhaltszusammenfassung zur Seite Nr. 2
CAUTION DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. WARNING TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. Safety Precautions Refer all work related to the installation of this product to qualified service personnel or system installers. Do not block the ventilation opening or slots on the cover. Do not drop metallic parts through slots.This could permanently damage the appliance. Turn
Inhaltszusammenfassung zur Seite Nr. 3
Safety Precautions Warning: The lightning flash with an arrowhead symbol, within an Electrostatic-sensitive device. Use proper equilateral triangle, is intended to alert the user to the CMOS/MOSFET handing precautions to avoid presence of uninsulated ” dangerous voltage” within the electrostatic discharge. product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons UNPACKING Unpack carefully. The exclamation point within an equilateral triang
Inhaltszusammenfassung zur Seite Nr. 4
Important Safeguards Read Instruction---All the safety and operating instructions should be read before the init is operated Retain Instructions---The safety and operating instructions should be retained for future reference. Heed Warnings—All warnings on the unit and in the operating instructions should be adhered to. Follow Instructions—All operating and use instructions should be followed Cleaning—Unplug the unit from the outlet before cleaning. Do not use liquid cleaners or aerosol cleaner
Inhaltszusammenfassung zur Seite Nr. 5
Table of Contents 1. Product Features………………………………………………………..………….1 2. Part Names………………………………………………………..…………………2 2.1 Front panel……………………………………………………..………………...2 2.2 Back panel…………………………………………..……………………………3 2.3 Remote Controller…………………………………..……………………………4 3. Installation..........……………………………..…………………………….....…….5 4. Function keys illustration………………………..………………………………..7 5. Live Display………………………………………….………………….…………..10 5.1. System Login……………………………………….…………………………..10 5.2. Live Display and Basic Operat
Inhaltszusammenfassung zur Seite Nr. 6
1. Product Features 16/8 CH Real-Time Digital Video Recorder Quadruple operation: Recording, Live view, Playback & Remote viewing 16/8 Color and/or B/W camera inputs (NTSC/PAL) MPEG-4 compression with resolution up to 720*480 (NTSC) / 720*576 (PAL) Real time recording (up to 25/30 FPS) per channel Real time live display (up to 25/30 FPS) per channel Real time playback (up to 25/30 FPS) per channel 16/13/10/9/7/4 windows or full-screen display 4 audio inputs, 1 audio output. Synchroniz
Inhaltszusammenfassung zur Seite Nr. 7
2. Part Names 2.1 Front Panel 5 4 3 2 1 7 15 14 13 12 11 10 9 8 6 1 7 Jog Dial (inner) and Shuttle Ring (outer) Playback Buttons Jog Dial: Press to start playback A. Rotate in paused playback to move Press to pause playback forward or backward to the next recorded Press to stop playback image Press to fast forward playback B. In Setup Menu, rotate to select the Press to fast rewind playback options in the column (Same as keys) Press to mute status On/Off 8 Shuttle Ring: LAN Active I
Inhaltszusammenfassung zur Seite Nr. 8
2.2 Back Panel Video 1-8 Video 9-16 In In 1 3 5 V1 V2 V3 V4 V5 V6 V7 V8 V9 V10 V11 V12 V13 V14 V15 V16 Out Out Power 2 4 Audio In Call Monitor 1 2 3 4 SCSI 75 75 Ω Ω NTS C /P AL 23 9-16 1-8 Alarm Out Alarm In Main Monitor USB Audio C 4 3 2 1 8 7 6 5 4 3 2 1 22 RS232#1 LAN RS232#2 CVBS Y/C VGA Out NO NC C 8 7 6 5 16 15 14 13 12 11 10 9 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 1 Video Input Connectors (Video In 1-8): BNC connector
Inhaltszusammenfassung zur Seite Nr. 9
2.3 Remote Controller The ERC100 remote controller is an accessory to enhance the handy operations. You can do all the settings and operations by the remote controller. The effective distance is up to 10 meters without any obstacle. 1 2 Power Button 1 Main Power ON/OFF 3 4 Eject Button 2 Press to control the ejection insertion of the CD-RW disc tray. ID Buttons 3 One Remote Controller can control up to 4 DVRs. Press the buttons to switch the controlled ID (DVR1~DVR4). The default setting
Inhaltszusammenfassung zur Seite Nr. 10
3. Installation Camera In 1~8 Camera In 9~16 Audio In 1~4 Call Monitor Video 1-8 Video 9-16 In In V1 V2 V3 V4 V5 V6 V7 V8 V9 V10 V11 V12 V13 V14 V15 V16 Out Out Power Audio In Call Monitor 1 2 3 4 SCSI 75 75 Ω Ω NTS C /P AL 9-16 1-8 Alarm Out Alarm In Main Monitor USB Audio C 4 3 2 1 8 7 6 5 4 3 2 1 RS232#1 LAN RS232#2 CVBS Y/C VGA Out NO NC C 8 7 6 5 16 15 14 13 12 11 10 9 Audio Out Ethernet Modem Disk Array Main Monitor (Y/C) Alar
Inhaltszusammenfassung zur Seite Nr. 11
Optional Connection VGA Monitor Connect the VGA monitor output connector to a VGA monitor. The VGA monitor displays selected live or recorded cameras in any available format. Call Monitor Connect the Call monitor output connector to a TV monitor. This monitor displays the full screen images of cameras associated with alarms or images from the installed cameras sequentially. Alarm In Connect Alarm In 1-16 to NC or NO type of alarm signals. Please make sure to setup the software configurations
Inhaltszusammenfassung zur Seite Nr. 12
4. Function Keys Illustration Full/Zoom Seq. Z+ Z- Go Pr. Event Status Menu The Function Key Panel can operate 2 levels function-General Mode and PTZ Control Mode. F+ F- Seq. Pr. Live/Play Search Archive The levels are distinguished by icon colors: I- Set Pr. I+ General Mode – White ( For EDR1680 operation) CH Set Del PTZ Control Mode– Cyan (For extensional PTZ camera if connected) Auto Pan Set Pan The default panel function is under General Mode. Press “PTZ” button to switch to PTZ contr
Inhaltszusammenfassung zur Seite Nr. 13
Status There are four types of status display on the bottom of the screen. Press to display Date/Time & HDD storage status. Press again to display Date/Time & Camera Status. Press again to display Date/Time & Alarm Inputs. .Press again to control the Date/Time & Alarm Outputs Press again to close the display. Date/Time HDD recorded percentage Show the details if motion or alarm triggered. From left to right, each light stand for camera 1~16 (eDR880=1~8) Green=Recording, Grey=Not Recording, Wh
Inhaltszusammenfassung zur Seite Nr. 14
A. Press to move focus window Up, Down, Left & Right in live display mode. B. In setup Menu Dialog, press to move between columns (Same as Shuttle), press to select options (Same as Jog). C. Once the Simulated keyboard pop up, use to move among the alphanumeric keys. (Same as JOG) (Enter) A. In Main Menu Setup, press to enter the Menu Dialog. B. Press to save the configuration. C. In Motion Detection Setup, press to toggle the Detect Area. D. Press to confirm th
Inhaltszusammenfassung zur Seite Nr. 15
5. Live Display 5.1 System Login If the user does not login the system, he will be treated as a guest and can only view the live video and system status. To login the system, press (Menu) button, the system login dialog and simulated keyboard will appear on screen as below allowing user to enter appropriate Login name and password. (For Operator, the factory default value for both is operator, for Supervisor, the factory default value for both is supervisor, for Administrator, the fact
Inhaltszusammenfassung zur Seite Nr. 16
There is always a focus window surrounded by a white frame and it can be moved among split windows by using buttons. Full/Zoom Switch the focus window to full screen mode. Press again to Digital Zoom-in (X2) the selected area (Show X2 at the right lower corner on the display). Press again to return to previous static display. On Full screen display, you may also press to return to previous static display. Multi-window display Press to change display differe
Inhaltszusammenfassung zur Seite Nr. 17
6. Setup Menu For entering the system setup menu, the user has to login as an Administrator level. To setup the behaviors of the system, please press “Menu” button on the front panel. The Setup Menu shown as below will appear on screen. Use buttons or “Jog” to switch items in the row. Use buttons or “Shuttle” to enter the submenu or return to upper level. Press “Enter” button to close Setup Menu and enter the selected Configuration Dialog. The “>” shows on the item means a
Inhaltszusammenfassung zur Seite Nr. 18
6. 1 Menu flowchart Camera > General Advanced Motion Detection Global Motion Action Calendar VLoss Action System > General Hard Disk Alarm Input > Alarm Action Network Dial-up E-mail Display > Main Monitor Seq Call Monitor Seq Password Logout 18
Inhaltszusammenfassung zur Seite Nr. 19
6.2 Camera Setup 6.2.1 Camera-General Setup Figure 1 Camera Tag Default settings are Cam1~Cam16 (Cam1~Cam8 for eDR880). User may move to “Edit” icon and press “Enter” button (Simulated keyboard will pop up once you start the edit function- Figure 1) to edit the camera title (total 10 characters available). Move to “OK”icon after finished and press “Enter” to confirm editing. Press “Exit” button to return to previous dialog. Installed Select “ON” if the corresponding camera is installed. All the
Inhaltszusammenfassung zur Seite Nr. 20
6.2.2 Camera-Advanced Setup Camera Tag Select the corresponding camera Cam1~Cam16 for further setting. Time Type 4 options of time type are available. Default value is “On Duty”. The setting of each time type please refer Chapter 7 Calendar setup menu. Motion Select “ON/OFF” to enable/disable the Motion detection for corresponding camera.Default value is “ON”. While the “ON” option is selected, the Config icon will be enabled for user -> to configure the motion detection behavior. Mov