Inhaltszusammenfassung zur Seite Nr. 2
www.jacksonmsc.com Many Jackson dishmachines are equipped with electrical STEPS solenoid valves to allow for automatic fill and rinse. These valves are designed to specific tolerances and design aspects that must 1. Remove the top screw with the 5/16” nutdriver. Remove the be met in order to function properly. screw and the data plate and set to the side. Jackson offers repair kits for replacing some of the wear items associated with solenoid valves which will allow you to save money in that re
Inhaltszusammenfassung zur Seite Nr. 3
www.jacksonmsc.com Prying open the coil wire cover Loosening the conduit nut 4. When replacing the coil, ensure that when removing the coil wire cover that care is taken not to damage the wires inside. Using the 7. Using a pair of channel locks, gently loosen the conduit retain- medium flathead screwdriver, gently use it to open the cover ing ring for the conduit nut. Once it is loosened, use your fingers to enough to where it could be pulled off. unscrew and remove it. 8. Pull the conduit away
Inhaltszusammenfassung zur Seite Nr. 4
www.jacksonmsc.com to remove the valve in order to perform this and any further steps. Be careful not to damage the plumbing assembly. Only use the pipe wrench enough to where you can spin the valve bonnet off with your hand. Removing the diaphragm Removing the valve bonnet 17. Remove the diaphragm retainer and then the diaphragm itself. Many problems associated with a solenoid valve can be traced to 13. Slowly remove the valve bonnet. Note: The spring for the a clogged pilot port in the diaphra
Inhaltszusammenfassung zur Seite Nr. 5
www.jacksonmsc.com 22. With the mesh screen removed, look down into the valve and verify it is not clogged. Remove any foreign objects from the valve body that would obstruct flow. 23. Reassemble the valve, reversing the steps needed to take it apart. Replace defective replacement parts with new parts from ordered kits. Ensure that components are sufficiently tightened to prevent leakage. AFTER MAINTENANCE ACTIONS Reconnect the incoming water (if disconnected) and turn on. Then restore power to