PurePac
Electronic Air Purification System
PB1900-0604
filtration.Optional TechSorb High Mass Zero Dust
General
bonded activated carbon is available for gas
The Flanders-Precisionaire PurePac Electronic Air
phase/odor control, making PurePac the IDEAL
Purification System is designed for reliable, high effi-
SOLUTION for quality indoor air.
ciency air filtration required in today's commercial
building environments. It is available in both side Configuration
access housings and front access units,
Inhaltszusammenfassung zur Seite Nr. 2
The operating cost to move ventilation air through a fil- Today's IAQ Challenges tration system is directly related to the filter is resist- The effort to increase performance and efficiency of ance. PurePac's low and constant 0.25î w.g. resist- buildings has resulted in tighter construction and ance results in reduced fan horsepower and a signifi- reduced air infiltration. Airborne particulate and gas cant energy savings compared to conventional filtra- phase contaminants released from pain
Inhaltszusammenfassung zur Seite Nr. 3
PurePac Delivers charging and collecting stages. This assures that all available floor space, up to 30% in some instances. system air is filtered. PurePac's low resistance to airflow results in reduced Conventional media filters rely on fiber density for par- fan horsepower and fan energy cost. Over a period of ticulate removal efficiency. A media filter is rated effi- time, this reduction amounts to significant savings in ciency is based on the average efficiency over the fil- energy costs.
Inhaltszusammenfassung zur Seite Nr. 4
PurePac Front Access Units PLC Control automatic 30 Gallon Detergent or manual operation. Dispenser liquid level sen- sor and flow control valve. Model FA-0604 (metal mesh System Accessories prefilters removed) solenoid valve, backflow preventer, Y- strainer and ball valve. Options Utilities PurePac is available with TechSorb HMZD bonded, Electrical activated carbon panels for gas phase contaminant Standard: 120 Vac, 1 ph, 60 Hz and odor control. Since the granules are locked Optional: 208-230
Inhaltszusammenfassung zur Seite Nr. 5
PurePac Front Access Units Model Number Development Unit Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Front Nominal Nominal Access Height Width 1. From the Size Selection Table below, select the Model FA with Air Volume and Dimensions that meet the required efficiency. FA 06 06 2. Multiple Model FA units of the same height may be Represents a PurePac Front Access unit, model grouped together to create larger, multi-section units. FA0606,
Inhaltszusammenfassung zur Seite Nr. 6
PurePac Side Access Units PLC Control automatic 30 Gallon Detergent or manual operation. Dispenser liquid level sen- sor and flow control valve. Conforms to ANSI/UL System Accessories STD 867 for Electrostatic Model FA-0604 (metal mesh solenoid valve, backflow preventer, Y- Air Cleaners prefilters removed) strainer and ball valve. System Description System Accessories PurePac Side Access Model (SA) is a factory pack- Each PurePac Side Access system is furnished with aged system including the si
Inhaltszusammenfassung zur Seite Nr. 7
PurePac Side Access Units Model Number Development Unit Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1. From the Size Selection Table below, select the Model Side Nominal Nominal SA with Air Volume and Dimensions that meet the Access Height Width required efficiency. 2. Multiple Model SA units of the same height may be SA 02 03 arranged side-by-side to create a larger, multi-section unit. Specify one unit with left hand and one unit wit
Inhaltszusammenfassung zur Seite Nr. 8
Engineering Specifications A. General manifolds containing brass spray nozzles, located on both the air entering and air leaving side of each The electronic air cleaner shall be the two stage, module tier. Complete, effective washing of all ion- dual voltage, plate type electrostatic precipitator, izing-collector cell surfaces and all appurtenances sized to clean the airflow capacities scheduled on shall be provided. Drive motors, used to oscillate the Contract Documents at an efficiency of at l