Inhaltszusammenfassung zur Seite Nr. 2
1 i a j b k c l d e f m g h 234 567 MACRO 5SLR 10 0.2x 0.4x 1x 2x 3x POWER RESET MACRO 5 SLR SET SEL MOD
Inhaltszusammenfassung zur Seite Nr. 3
MACRO 5SLR 89 10 11 0.2x 0.4x 1x 2x 3x POWER RESET 10 MACRO 5 SLR abcdefghi 12 13 14 3x 15 16 17 0.2x 0.4x 1x 2x MAC MAC SET SEL MOD
Inhaltszusammenfassung zur Seite Nr. 4
18 19 20 21 22 23 R 24 25 26 0.2x 0.4 A BCD E F G H I J K L M N OP 1 2 3 4 POWER RESET 5 6 7 8 9 10 7 8 11 12 6 7 8 9 20 1 SET SEL MOD
Inhaltszusammenfassung zur Seite Nr. 5
English 3 English Introduction The Polaroid Macro 5 SLR is a simple to operate, fully automatic, portable camera designed for medical and dental docu- mentation of patient condition, manufac- turing, quality control, law enforcement, and other applications that require close-up photographs. The camera uses Polaroid self-developing instant color films, so you know right away that you have the picture you need. The camera produces reproductions at: 0.2X (20%), 0.4X (40%), 1X (100%), 2X (200%)
Inhaltszusammenfassung zur Seite Nr. 6
4 English Accessory filter kits Load the batteries • Polarizer kit to reduce reflections from the The camera requires four AA batteries to flash units when photographing glossy or provide power for the ranging lights. Alka- glass subjects (PID No. 619909) line batteries (standard or rechargeable) are recommended; rechargeable NiCad • Fluorescein kit for external ophthalmic batteries also can be used. photography includes a #8 yellow barrier The battery compartment is located in filter and #47A
Inhaltszusammenfassung zur Seite Nr. 7
English 5 Load the film The control panel (11) The camera uses Polaroid HighDefinition a Power button instant self-developing color films. Type Press to turn on the camera. The flash 990 film is recommended; GridFilm and units will begin charging, and the green Spectra/Image films also can be used. indicators will light up when the camera Each film pack contains 10 sheets of film is ready for picture-taking. and a battery that provides power for the The camera will turn off if the power exposu
Inhaltszusammenfassung zur Seite Nr. 8
6 English Set the magnification Take the picture Turn the magnification selector knob to Look through the viewfinder, and reframe the desired setting (12). The knob will the subject as needed. click into position at each magnification; Press the shutter button all the way to the camera will not function if the knob is take the picture (16). between lens settings. The picture will be automatically In addition to the magnification, the ejected from the front of the camera selector shows the camer
Inhaltszusammenfassung zur Seite Nr. 9
English 7 Date display module Flash control (23) The date display module (21) allows you The two built-in electronic flash units are to print the date or the day/time on pic- designed to provide even illumination at tures (22). all reproduction scales. You can turn off either flash unit if side lighting is needed Setting the date to show texture or elevation. The light 1 Press MOD (mode) repeatedly until the output from the remaining flash unit will desired date sequence is displayed: be increa
Inhaltszusammenfassung zur Seite Nr. 10
8 English GridFilm Troubleshooting Difficulty focusing This film has a grid pattern which is created during manufacture. The grid The ranging lights may be difficult to see pattern appears as an overlay on any when using the camera in very bright picture taken with the film. light, or when photographing very dark The pattern consists of 17 vertical and subjects. If you have difficulty seeing the 13 horizontal lines. ranging lights: To help you define location on the grid, • Check that the cam
Inhaltszusammenfassung zur Seite Nr. 11
English 9 Care and Maintenance EMC statement Lens care: Avoid touching the lens. To Polaroid Corporation certifies that this remove dust or fingerprints, breathe on product conforms to the following the lens and wipe it gently with a clean, standards: soft facial tissue. Do not use silicone- Safety: Low Voltage Directive 73/23/EEC treated eyeglass tissues. EMC: EN55022, Class B; EN50082-1; IEC Temperature: The camera and film are 801-2, 801-3, 801-4 designed for use at temperatures of 55-95
Inhaltszusammenfassung zur Seite Nr. 12
10 English Free technical assistance Battery cautions If you need assistance or additional infor- • The batteries used in this device may pre- mation about specific applications, call sent a risk of one or more of the following toll free at 1-800-225-1618, Mon.-Fri., 8 AM occurrences: Release of toxic materials, to 8 PM (Eastern time). Or, write to the release of flammable vapors, rise in Customer Care Center, Polaroid Corpora- surface temperature. Do not recharge, tion, 201 Burlington Road, Bed
Inhaltszusammenfassung zur Seite Nr. 13
English 11 FCC Notice (U.S.A. only) Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are de- signed to provide reasonable protection against harmful interference in a residen- tial installation. This equipment generates, uses and ca
Inhaltszusammenfassung zur Seite Nr. 14
Note to printer: Update Polaroid addresses on the gatefold of the manual. Reverse the band text to white; background: PMS 403 grey. Polaroid Offices and Service Centers Africa Deutschland México Puerto Rico Polaroid (Europa) B.V. Polaroid GMBH Polaroid de México S.A. de Polaroid Caribbean Jozen Place Sprendlinger Landstrasse C.V. Corporation Northdowns Office Park 109 Paseo de la Reforma 195, Centro de Seguros 17 Georgian Crescent 63069 Offenbach, Germany Piso 17 Ave. Ponce de León 701 Bryanston