Inhaltszusammenfassung zur Seite Nr. 1
Build-up Unit
Model AK-HBU931P
Before attempting to connect, operate or adjust this product, please read these
instructions completely.
Inhaltszusammenfassung zur Seite Nr. 2
Safety precautions FCC Note: CAUTION This device complies with Part 15 of the FCC Rules. RISK OF ELECTRIC SHOCK To assure continued compliance follow the attached DO NOT OPEN installation instructions and do not make any unauthorized modifications. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. This equipment has been tested and found to comply REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. with the limits for a class A digital
Inhaltszusammenfassung zur Seite Nr. 3
Contents Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Operating precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inhaltszusammenfassung zur Seite Nr. 4
Controls and their functions Front Panel Top Panel 1 5 4 6 3 2 1 Lens guide 4 Camera mounting base The 2/3z box-type lens is attached by hooking it onto this This is used to attach the camera. For details, refer to guide. Align the guide pin of the lens with the center the operating instructions of the camera concerned. groove, and attach. 5 Optical fiber cable for connecting camera [CAM] 2 Lens anchoring knob Use this to connect the unit to the optical fiber connector This is rotated clockwis
Inhaltszusammenfassung zur Seite Nr. 5
Controls and their functions Bottom Panel Right Side Panel 7 8 9 7 Screw hole for mounting tripod (3/8-16UNC) 8 Hook for securing cable This is used to attach the unit to a tripod or other The optical fiber cable from the CCU is fastened to this accessory. hook. 9 Clip This is used to attach the accessories. 5
Inhaltszusammenfassung zur Seite Nr. 6
Controls and their functions Left Side Panel Operation panel ;: < 78 9 G H I 2 4 1 3 5 6 D E F BREAKER AC OUT(200VA) MAIN ALARM RESET 12OV AC 80Hz CCU = > @ ; : = ?@ B C JK L > A : Cable clamp 1 VF power switch [VF POWER] This is used to clamp the optical fiber cable from the This is used to set the viewfinder’s power to ON or OFF. CCU. When it is lighted, the viewfinder’s power is OFF. ; Optical fiber connector 2 Front tally ON/OFF switch [FRONT TALLY] OPT FIBER connector (EDW.3K.93C.CLC mad
Inhaltszusammenfassung zur Seite Nr. 7
Controls and their functions ; 4:3 MARKER switch E RET B switch [RET B] This is the 4:3 marker ON/OFF switch. When the 4:3 This is used to select the RET B switch. When it is marker is ON, the brightness modulation can be set to lighted, the video signals of RET B selected by the ON or OFF. camera are output to the viewfinder. < 4:3 brightness modulation level control F User switch [USER SEL] This is used to vary the brightness modulation level This enables control to be exercised over the ON/
Inhaltszusammenfassung zur Seite Nr. 8
Mounting methods Mounting the lens Mounting the camera 1 Mount the camera on the camera mounting base, and U-shaped groove slide the camera toward the front along the groove until it Lens guide clicks into place. Y /C NAM R G B FILTER LOCAL MONI SEL Lens clamp 1 A lever CAM ON /ON VTR GAIN LOW OUTPUT CAM W.BAL B MID BAR A STBY SAVE HIGH TEST PRST SD CARD PTT USER SEL Detaching the camera from the camera mounting base Lens#Release Lens#Lock While pushing the red lever, move the black lever
Inhaltszusammenfassung zur Seite Nr. 9
Connections ≥ Connect the multi-format camera (and lens) to the build-up unit as shown in the figure below. ≥ Connect the cable from the CCU to the connector on the build-up unit. ≥ Connect the cable of the build-up unit to the connector on the multi-format camera. 8z LCD viewfinder R Y /C NAM G B (AK-HVF931P) FILTER LOCAL MONI SEL 1 A CAM/VTR GAIN OUTPUT W.BAL ON ON LOW CAM B MID BAR A STBY SAVE HIGH TEST PRST SD CARD PTT USER SEL Multi-format camera (AK-HC931P) Cable Build-up unit Cable
Inhaltszusammenfassung zur Seite Nr. 10
External dimension drawings VF POWER FRONT TALLY MARKER CENTER ON/OFF CURSOR 1 2 RET A RET B USER SEL VF MARKER H–POSI V–POSI WIDTH HEIGHT VF DETAIL MONI SEL RG ON Y/G B EXT OFF FILTER MENU SELECT PIP 12345 A B C D E LOCAL x0.8 ND CC 23-1/15z (585 mm) 12-5/8z (320 mm) 10 13-5/16z (337.5 mm)
Inhaltszusammenfassung zur Seite Nr. 11
Specifications Power supply: AC 220 V (supplied from CCU) Power consumption: 8 W (main unit only) 1indicates safety information. Switch functions: AC OUT reset, viewfinder power, front tally ON/OFF, CENTER marker, CURSOR, cursor memory 1, cursor memory 2, 4:3 MARKER, ND filter selection, LOCAL, CC filter selection, menu ON/OFF, menu JOG, RET A switch, RET B switch, user, VF DETAIL, MONITOR output selection, P in P function ON/OFF, P in P position selection Adjustment functions: H-POSI, V-POSI, W
Inhaltszusammenfassung zur Seite Nr. 12
PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY UNIT COMPANY OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA Executive Office: 3330 Cahuenga Blvd W., Los Angeles, CA 90068 (323) 436-3500 EASTERN ZONE: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7621 Southeast Region: 1225 Northbrook Parkway, Ste 1-160, Suwanee, GA 30024 (770) 338-6835 Central Region: 1707 N Randall Road E1-C-1, Elgin, IL 60123 (847) 468-5200 WESTERN ZONE: 3330 Cahuenga Blvd W., Los Angeles, CA 90068 (323) 436