Packing List 1 What’s in the box • iCAM4100 - IrisCamera • Power Adapter Input: 110~240V AC - 1.5AMP 50/60Hz Output: 12V DC - 5.0AMP • Power Cable for 110V • CAT5 Ethernet Cable • Quick Start Guide • Security Screw Wrench Required Equipment (not included with iCAM4100) • Server Computer (refer to the Hardware Manual for details) • Ethernet Switch • Ethernet Wiring • Uninterruptible Power Supply
Inhaltszusammenfassung zur Seite Nr. 3
iCAM4100 in the IrisAccess System 2 Ethernet Door Control RS-422 Serial Network Switch ICU DCU The iCAM4100 is a two-eye iris camera used to capture the iris images of the user. The iCAM includes an alignment indicator behind the mirror and voice prompts to assist the user. A Vacuum Fluorescent Display (VFD) displays system time, date, and user guidance. When used in a typical access control application, the iCAM is placed near the secured portal to provide user identification. The option
Inhaltszusammenfassung zur Seite Nr. 4
Installation Requirements 3 bottom of mirror 61” 55” (155mm) (140mm) floor • The recommended mounting height for the iCAM4100 is 140cm (55 inches) from the floor to the bottom of the unit. This mounting height can be adjusted to accommodate the average user height at the installed location. • High amounts of ambient light must be avoided. Intense light sources such as sunlight or halogen lamps may reduce the image capture performance of the iCAM, this may result in an increas
Inhaltszusammenfassung zur Seite Nr. 5
iCAM4100 Installation 4 1. Remove the three security screws (use included security bit wrench) from the bottom of the iCAM. Front Back 2. While gently pulling the cover upward, pull forward simultaneously. Screw to fix the plate 2 1 3. Unscrew the installation plate screw and slide the body of iCAM4100 upward to separate from the installation plate. 4. Position the installation plate on the desired wall near the secured door and mark the holes as the figure below illustrate
Inhaltszusammenfassung zur Seite Nr. 6
iCAM4100 Installation (cont’d) 5 196 5 6.4801 156 15 16 Hole 6 45 2.2 7.6 Dimensions and Screw Holes in the Installation Plate (mm unit) 80 62.8 35.5 11 2.2 1 Installation Plate Rotation Part with Front Enclosure Dimensions of iCAM4100 (mm unit) 208 235.5 139 217 49.5 6 6 4 208 16.2 29
Inhaltszusammenfassung zur Seite Nr. 7
iCAM4100 Installation (cont’d) 6 6. Route the power line, network line, and other necessary cables through the installation plate hole. 7. Using the appropriate fasteners for the material in which the iCAM will be mounted, secure the installation plate. 8. Slide the iCAM4100 body into the installation plate and fasten it with the retaining screw. 9. Attach the wires from the 12VDC power supply to the screw terminal connections. The +12VDC (white wire) power connects to the + (p
Inhaltszusammenfassung zur Seite Nr. 8
iCAM4100 Configuration 7 Changing the IP Address of the iCAM * Note: The IP Address of each iCAM must be changed individually. Do not connect more than one un-configured iCAM to the network at any one time to avoid IP Address conflicts. Any computer with a web browser which supports graphics (ex. Internet Explorer) can be used to configure the iCAM4000/4100. 1. Set the computer to the static IP of 192.168.5.1 - subnet 255.255.255.0 2. Open the web brows
Inhaltszusammenfassung zur Seite Nr. 9
iCAM4100 Configuration (cont’d) 8 5. Select Network Settings. 6. Enter the new IP address for the iCAM (default = 192.168.5.100) 7. Enter the new Subnet Mask for the iCAM (default = 255.255.255.0) 8. Enter the new Broadcast Address for the iCAM (default = 192.168.5.255) 9. Enter the new Default Gateway for the iCAM. (default = 192.168.5.254) 10. Click OK to save changes and to open network settings verify screen. If the new iCAM IP address is still on the same subnet as the computer:
Inhaltszusammenfassung zur Seite Nr. 10
iCAM4100 Configuration (cont’d) 9 Once all iCAMs have been configured Once all iCAMs have been configured, the computer IP Address can then be changed back to its original IP Address or to the new IP Address as required to communicate to the rest of the IrisAccess™ system. SmartCard Integration • The iCAM4010-E1 and iCAM4010R-E1 have a built-in Integrated Engineering Smart ID smart card reader, and the iCAM4010-H1 and iCAM4010R-H1 have a built-in HID iClass smart card reader. • The