Inhaltszusammenfassung zur Seite Nr. 1
SpectraLink 6300 MCU
Facility Preparation
SpectraLink 6000 System
July 2008 Edition
1725-36121-001
Version J
Inhaltszusammenfassung zur Seite Nr. 2
Facility Preparation: SpectraLink 6000 System: SpectraLink 6300 MCU Trademark Information Notice Polycom® and the logo designs Polycom, Inc. has prepared this document for SpectraLink® use by Polycom personnel and customers. The LinkPlus drawings and specifications contained herein Link are the property of Polycom and shall be neither NetLink reproduced in whole or in part without the prior SVP written approval of Polycom, nor be implied to Are trademarks and registered trademarks of
Inhaltszusammenfassung zur Seite Nr. 3
About this Guide This manual describes the installation procedure for Polycom’s SpectraLink 6000 System with a SpectraLink 6300 Master Control Unit (MCU). The procedures described in this manual are those that take place after the installation-planning procedure. You should already know the equipment requirements and installation locations. For example, you should know where each Base Station will be installed, and how many Interface Modules are required. Polycom Model Numbers This do
Inhaltszusammenfassung zur Seite Nr. 4
Facility Preparation: SpectraLink 6000 System: SpectraLink 6300 MCU LinkPlus Interface Guide (1725-361xx-001 where xx indicates a number corresponding to the type of PBX) Available at http://www.polycom.com/usa/en/support/voice/wi- fi/pbx_integration.html Customer Support Polycom wants you to have a successful installation. If you have questions please contact our Customer Support Hotline at (800) 775-5330. The hotline is open Monday through Friday, 6 a.m. to 6 p.m. Mountain time. F
Inhaltszusammenfassung zur Seite Nr. 5
Contents 0 About this Guide ......................................................................3 Polycom Model Numbers..................................................................3 Related Documents.............................................................................3 Customer Support...............................................................................4 Icons and Conventions.......................................................................4 1 Installation O
Inhaltszusammenfassung zur Seite Nr. 6
Facility Preparation: SpectraLink 6000 System: SpectraLink 6300 MCU Program Telephone System.............................................................29 Connect Cables from Base Stations and Phone Lines to Demarc Blocks ...................................................................................30 4 Connect Power to Shelves .......................................................35 Run Conduit To Shelf.......................................................................35 5 Inst
Inhaltszusammenfassung zur Seite Nr. 7
1 Installation Overview Installation has three phases. In most cases, a separate person is responsible for each phase. 1. Site preparation and wire installation: Usually done by a wire technician or contractor, with the assistance of a customer representative such as a project manager. Please refer to the SpectraLink 6300 MCU: Facility Preparation manual for more information. 2. Installing the SpectraLink system: Done by Polycom or one of our certified distributors. 3. Programming th
Inhaltszusammenfassung zur Seite Nr. 8
Facility Preparation: SpectraLink 6000 System: SpectraLink 6300 MCU Installation Steps and Responsibilities Wire Field Customer Task Contractor or Service Project Mgr/ Description Electrician Engineer Sys Admin Site Preparation Required materials provided by customer Prepare location and arrangement of shelves Prepare –48V power for shelves Run cables to Base Stations Terminate cables at Base Stations Prepare and install demarc blocks Program Telephon
Inhaltszusammenfassung zur Seite Nr. 9
2 SpectraLink 6000 System Description This section generally explains the installation and site requirements of the SpectraLink 6000 System. The SpectraLink 6000 System is a wireless communication system that allows hand-held Wireless Telephones to communicate using the existing telephone system. The SpectraLink 6000 System’s advanced micro-cellular architecture utilizes Base Stations, or cells, located throughout the facility to accommodate on-premises roaming. As a handset user moves
Inhaltszusammenfassung zur Seite Nr. 10
Facility Preparation: SpectraLink 6000 System: SpectraLink 6300 MCU SpectraLink 6000 System The Master Control Unit The Master Control Unit (MCU) is the processing center for calls to and from the SpectraLink 6000 System. It consists of at least one primary shelf (MCS300) and may have up to nineteen expansion shelves. Residing adjacent to the telephone switching equipment, the MCU operates as a standalone, external system while maintaining full PBX functionality for handset users. T
Inhaltszusammenfassung zur Seite Nr. 11
SpectraLink 6000 System Description provide the wireless link to the handsets, are wired directly to the MCU. The SpectraLink 6000 System topology Components in the SpectraLink 6000 System are designed in a star topology. At the center is the SpectraLink 6300 MCU. The primary shelf contains the system controller, which manages the call processing for the wireless network. Additional expansion shelf controllers manage intra-shelf calling and work with the system controller to pass call
Inhaltszusammenfassung zur Seite Nr. 12
Facility Preparation: SpectraLink 6000 System: SpectraLink 6300 MCU 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 Shelf 2 - Expansion Shelf Shelf 1 - Primary Shelf 1 2 3 4 5 6 7 8 9 10 11 12 Intershelf Junction Panel Shelf 3 - Expansion Shelf 1 2 3 4 5 6
Inhaltszusammenfassung zur Seite Nr. 13
SpectraLink 6000 System Description Shelf Shelves are designed for 19” rack or wall mounting. Each shelf has 12 universal card slots. The first two slots are reserved for controller cards, the remaining ten slots are for Interface Modules. Wiring to each card is on the front panel. Power is -48V DC through the back or side panel. System Controller (CSC or CSO301, 306, and 320) Each system requires one system controller card, which occupies two slots (slot 1 and 2) in the main shelf. Th
Inhaltszusammenfassung zur Seite Nr. 14
Facility Preparation: SpectraLink 6000 System: SpectraLink 6300 MCU Operator’s Console and software when the card is installed. Interface Modules of different interface types can be mixed within a shelf. Interface Modules are “hot swappable”; they can be removed and replaced without affecting service on the rest of the system. Intershelf Junction Panel (JPI300) The Intershelf Junction Panel (JPI300) connects Expansion Shelf Controllers on expansion shelves to the system controller, creati
Inhaltszusammenfassung zur Seite Nr. 15
SpectraLink 6000 System Description ccSpectraLink 6000 System The ccSpectraLink 6000 System is designed to meet the high simultaneous call capacity and advanced level of telephone feature integration of the call center environment. The ccSpectraLink 6000 System uses a special High Density Base Station which can be installed with minimal spacing (as little as 20 feet between Base Stations.) SpectraLink 6000 Wireless Telephones The SpectraLink 6000 Wireless Telephones are durable wireles
Inhaltszusammenfassung zur Seite Nr. 16
Facility Preparation: SpectraLink 6000 System: SpectraLink 6300 MCU SpectraLink 6020 Wireless Telephone Each handset requires a line appearance (port) from the telephone system. Typically the handset extension number corresponds with the user’s internal telephone extension number. On most switching systems the user’s desk phone and the handset port can be bridged so that incoming calls ring both phones simultaneously. Operator’s Console The system uses a proprietary software program f
Inhaltszusammenfassung zur Seite Nr. 17
3 Site Preparation The following steps must be completed before installing the system hardware. If the steps are not already completed refer to each individual section for details. MCU location prepared. Typically the MCU is installed in the telephone equipment room. This location must have sufficient backboard space or rack space, and -48 volt power available. The correct number of cross-connect blocks (or equivalent) are installed and connected to a 25-pair Telco wire terminated
Inhaltszusammenfassung zur Seite Nr. 18
Facility Preparation: SpectraLink 6000 System: SpectraLink 6300 MCU Required Materials Provided by Customer Required hardware Rack The shelves are designed to fit into a 19” mounting rack. Each shelf measures 15” high x 19” wide x 9” deep, and weighs approximately 35 pounds fully loaded. Backboard space As an alternative to rack mounting, the shelves can be wall-mounted to 3/4” plywood securely screwed to a wall. Screws Required to mount the shelves to the wall, or to secure it
Inhaltszusammenfassung zur Seite Nr. 19
Site Preparation Operator’s console PC A PC must be available to perform system administration and diagnostics The PC must conform to the following specifications: • An IBM-compatible personal computer, 486 or above (with a 16 MHz clock or faster) • A hard disk with at least 2 Mbytes free space • At least 640k bytes of RAM • MS-DOS 3.2 (or later), or MS-Windows 95 (or above) or NT • A 3 1/2" floppy-disk drive (high density, 1.44 Mbytes) • One RS-232 serial port for connection to the sy
Inhaltszusammenfassung zur Seite Nr. 20
Facility Preparation: SpectraLink 6000 System: SpectraLink 6300 MCU unlimited access to the Customer Support Hotline for additional assistance. Union labor In some areas strict labor union rules will preclude the SpectraLink representative’s ability to install the equipment without union assistance. If such rules are in force in the local area, the customer must ensure that sufficient union help is available at the scheduled installation time to carry out the following functions: • Inst