ملخص المحتوى في الصفحة رقم 1
UV100E Ultraviolet
Air Treatment System
OWNER’S GUIDE
® U.S. Registered Trademark
Copyright © 2001 Honeywell Inc.
69- 1442- 1
All Rights Reserved
ملخص المحتوى في الصفحة رقم 2
UV100E ULTRAVIOLET AIR TREATMENT SYSTEM HOW YOUR ULTRAVIOLET AIR TREATMENT SYSTEM WORKS When installed in forced air heating and cooling systems, your UV100E Ultraviolet Air Treatment System kills a high percentage of micro-organism contaminants in the air passing over it. Individual results depend on how carefully all installation and maintenance requirements are followed and on the actual amount of time your air delivery fan operates. You can capture and minimize micro-organism pass-throug
ملخص المحتوى في الصفحة رقم 3
UV100E ULTRAVIOLET AIR TREATMENT SYSTEM HOW YOU CAN CHECK YOUR ULTRAVIOLET AIR TREATMENT SYSTEM OPERATION WARNING UV Light Hazard. Harmful to bare skin and eyes. Can cause temporary or permanent loss of vision. Never look at the lamps while illuminated. Only view illumination by way of the light indicator located on the lamp knob. To prevent exposure to ultraviolet light, disconnect power to the ultraviolet air treatment system before servicing any part of the heating/air conditioning syste
ملخص المحتوى في الصفحة رقم 4
UV100E ULTRAVIOLET AIR TREATMENT SYSTEM HOW YOU CAN MAINTAIN YOUR ULTRAVIOLET AIR TREATMENT SYSTEM Your should regularly clean your ultraviolet lamps to maintain your air treatment system. And once every year, you must remember to replace your ultraviolet lamps. CAUTION Personal Injury Hazard. Power supply can cause electrical shock. Disconnect power supply before cleaning or replacing ultraviolet lamp(s). Do not open base unit or lamp knob; there are no user-serviceable components inside. CA
ملخص المحتوى في الصفحة رقم 5
UV100E ULTRAVIOLET AIR TREATMENT SYSTEM UV LAMP CLEANING REMINDER SCHEDULE INSTALLATION DATE: (month) , (year) YEAR JF M A M J J A S O N D M13516 Fig. 1. Ultraviolet lamp cleaning reminder schedule. CAUTION UV Lamp Burn Hazard. Harmful to bare skin. Can cause severe burns. Disconnect power 15 minutes before removing the ultraviolet lamp(s) IMPORTANT If the lamps in your model have external wires running along the glass surface, be sure to avoid pulling on those wires. To clean your lamps: 1.
ملخص المحتوى في الصفحة رقم 6
UV100E ULTRAVIOLET AIR TREATMENT SYSTEM 6. Wipe your lamps with a clean, dry cloth. 7. Put your clean lamps back into the unit base by following Replacing Your Lamps (Annually) section steps 5, 6, and 7. WARNING UV Light Hazard. Harmful to bare skin and eyes. Can cause temporary or permanent loss of vision. Never look at the lamps while illuminated. Only view illumination by way of the light indicator located on the lamp knob. To prevent exposure to ultraviolet light, disconnect power to the
ملخص المحتوى في الصفحة رقم 7
UV100E ULTRAVIOLET AIR TREATMENT SYSTEM 6. Continue lightly pushing in on the lamp while rotating it slowly counterclockwise. This should cause the lamp to drop into the bottom of the lamp well. 7. Rotate the lamp clockwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover. WARNING UV Light Hazard. Harmful to bare skin and eyes. Can cause temporary or permanent loss of vision. Never look at the lamps while illuminated. Only view illuminat
ملخص المحتوى في الصفحة رقم 8
Five-Year Limited Warranty Honeywell warrants this product, excluding lamps, to be free from defects in the workmanship or materials, under normal use and service, for a period of five (5) years from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option) within a reasonable period of time. If the product is defective, (i) return it, with a bill of sale or other da