Installation
Refer to the following pages for important information regarding the
installation of LCS and LCG ClimaPlus Combis. It is recommended
that installation be accomplished by a certified and properly trained
technician.
NOTE: When installing a ClimaPlus combi, humidity calibration must
be performed. This process takes approximately 45-60 minutes. (page 62)
Site, leveling
Minimum clearance sides and back:
2 in. (50 mm)
Service clearance, left side:
20 in. (500 mm)
Clearance for door ope
ملخص المحتوى في الصفحة رقم 2
INSTALLATION Unit weights: LCS 6: 270 lbs. (123 kg) LCG 6 335 lbs. (152 kg) LCS 10 334 lbs. (152kg) LCG 10 384 lbs. (174 kg) continued LCS 1020 484 lbs. (220 kg) LCG 1020 584 lbs. (265 kg) LCS 20 686 lbs. (312 kg) LCG 20 798 lbs. (362 kg LCS 40 972 lbs. (442 kg) LCG 40 888 lbs. (403 kg) 6) Installation models 6, 10, 1020 Fig. 3 Place floor stand at the installation place and level by adjusting legs. (Fig. 3). Minimum clearance required to neighboring equipment or walls. (page 59) Place th
ملخص المحتوى في الصفحة رقم 3
INSTALLATION Electrical requirements of gas units: Model Voltage Phase Cycle/Hz KW LCG-6 120 1 60 1 LCG-10 120 1 60 1 LCG-1020 208/240 1 60 1.5 Fig. 8 LCG-20 208/240 1 60 1.6 LCG-40 208/240 3 60 3.5 L N L L Choose conductor size according above tables and your local regulations. 1 2 3 IMPORTANT Gas units are voltage specific. Supply voltage must match voltage rated on data plate. Gas units are supplied with grounded power cord and plug. Fig. 9 Electric units are NOT supplied with power cord.
ملخص المحتوى في الصفحة رقم 4
Model Terminal Positions LCG-6 5 and 6 LCG-10 5 and 6 LCG-1020 5 and 6 LCG-20 6 and 7 LCG-40 5 and 6 Once conversion has been completed, a “total reset” of the CPU-PCB must be done. Record all end-user (custom) programs before undertaking a Total Reset. Secure all panels and covers. Total reset Turn on unit. Press and hold IQT Sensor key, IQT key, and PROG/START simultaneously and turn unit off. Release all keys. Wait at least 4 seconds and turn unit on. NOTE: With total reset proced
ملخص المحتوى في الصفحة رقم 5
INSTALLATION Water supply 9) Drain Connection (WA) Fig. 12 For drain connection (Fig. 12) use only steam temperature resistant pipe, diameter 2 in. (50 mm) and constant slope 5%. No hose should be used. WA Direct drain connection is possible, ventilated gap is an integrated part of the appliance (Fig. 13). Drain pipe should be supported to the wall/floor. Max. water discharge rate during Auto Flush:11 gal./min. (0.7 liter/sec.) Average drain water temperature: 150°F (65°C). Fig. 13
ملخص المحتوى في الصفحة رقم 6
INSTALLATION General 11) Technical Data Working place specific noise level: <70dB Average water consumption during operation: Model 6: 3.17 gal/hr (0.2 l/min.) Model 10: 6.7 gal/hr (0.42 l/min.) Model 1020: 10.9 gal/hr (.069 l/min.) Model 20: 13.2 gal/hr (0.83 l/min.) Model 40: 15.8 gal/hr (1.0 l/min.) Heat emission: Model Latent Sensible LCS/G-6 .64 W (2.30 kJ)/hr 84 W (2.93 kJ)/hr LCS-G-10 1.05 W (8.50 kJ)/hr 1.4 W (5.00 kJ)/hr LCS/G-1020 1.67 W (6.00 kJ)/hr 2.4 W (8.50 kJ)/hr LCS-G-20 2.13 W
ملخص المحتوى في الصفحة رقم 7
INSTALLATION continued DO NOT attempt to use any type of gas other than that specified on the data plate. Incorrect gas supply could result in fire or explosion resulting in severe injuries and/or property damage. To avoid possible serious personal injury, the installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-1988 or latest edition. In Canada, CAN/CGA-B 149.1 Natural Gas Installation Code CAN/CGA-B 149.2 Propane Installatio
ملخص المحتوى في الصفحة رقم 8
INSTALLATION During pressure testing note the following: continued 1. The unit and its individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system when test 1 pressures exceed ⁄2 psig (3.45kPa). Turn OFF main gas shut-off valve or main gas supply line. 2. The unit must be isolated from the gas supply piping system by closing its individual manual shut-off valves during any pressure testing of the gas supply 1 piping system at
ملخص المحتوى في الصفحة رقم 9
INSTALLATION Utilize elbows when necessary to avoid sharp kinks or excessive bending. For ease of movement, install with a “lazy” loop. Gas appliance must be disconnected prior to continued maximum movement. (Minimum movement is permissible to disconnect gas line. Couplings and hose should be installed in the same plane as shown at left. DO NOT OFFSET COUPLINGS. This results in twisting and undue torsion causing premature failure. Correct way to install metal hose for vertical traverse. Note