ملخص المحتوى في الصفحة رقم 1
Command
Console
SL
ملخص المحتوى في الصفحة رقم 2
REGULATORY FCC INFORMATION WARNING TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. ALSO, DO NOT USE THIS UNIT’S POLARIZED AS PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLETS UNLESS ALL THREE PRONGS CAN BE FULLY INSERTED 2. Changes or 1. Use the power and modifications not video cables supplied expressly approved by with the product to Z Microsystems could help prevent interfer- void user’s warranty. ence with radio and television reception. The
ملخص المحتوى في الصفحة رقم 3
TABLE OF CONTENTS SECTION PAGE Introduction ........................................................................................................................4 About This Manual ....................................................................................................4 Safety Precautions ....................................................................................................4 Product Description .....................................................................
ملخص المحتوى في الصفحة رقم 4
INTRODUCTION ABOUT MANUAL This Manual is also available on the Z Microsystems website (www.zmicro.com). We recommend you read this manual carefully and follow the instructions in the Installation chapter for verification of system functions and control settings. Safety Precautions DANGER: To avoid shock hazard: • Do not remove the covers around the Command Console • Do not connect or disconnect the Command Console during an electrical storm. • The power cord plug must be connected to a pr
ملخص المحتوى في الصفحة رقم 5
INTRODUCTION PRODUCT DESCRIPTION The ultra-slim Command Console SL model is designed for rapid deployable applications and fits any 19” RETMA rack or transit case. The Command Console SL model brings together a 19” (1280 x 1024) flat panel display, a full size water tight keyboard and track ball all in only 1.75” (1U) height. The Command Console SL model also solved cable retracting problems. An integral custom engineered articulating arm provides smooth cable management which eliminates cabl
ملخص المحتوى في الصفحة رقم 6
INSTALLATION SHIPMENT CONTENTS Ensure all of the following parts are in- cluded in the package received from Z Mi- crosystems. Verify all parts have not been damaged during shipment. If any of the parts are missing or damaged, immediately contact Z Microsystems Customer Service at 858-657-1000. • Command Console unit attached to the mounting plate • Power Cable • User Manual • Video Cable • Serial Cable Required Tools • Rack-mounting hardware • Phillips screwdriver, 2 pt. • 5/16 wr
ملخص المحتوى في الصفحة رقم 7
INSTALLATION HARDWARE INSTALLATION Remove the outer rack mounting slide On the rear unscrew the left and right channels from the Console. rear rack mounting brackets to free up the outer rack mounting slide channels from the Console. Press the spring loaded Z Locks towards Slide the channels back until they stop the middle to release the outer rack about half way back. This is a safety stop mount slide channels and at the same to prevent the Console from sliding out time slide the rack mou
ملخص المحتوى في الصفحة رقم 8
INSTALLATION Install Rails Both outer rack mount slide channels should be separated at this time. The slide channels come pre-assembled rear mounting bracket can be repositioned to fit a 24” deep rack. To fit a 25” rack, the as shown here. 8 Doc# 27-0032UM Rev A Issued 07/05
ملخص المحتوى في الصفحة رقم 9
INSTALLATION on each side to secure the Z-Lock mounts. To mount the channels on the front of the RETMA rails (in most cases), use two 10- 32 Phillips screws... Be sure to press the slide rail flat against On the rear of the cabinet frame, also use the RETMA rail as you tighten the screws. two Phillips screws on each rail to secure. On the slide rails, using a screwdriver and wrench, tighten the slide extension rail screw. Repeat on each side. 9 Doc# 27-0032UM Rev A Issued 07/05
ملخص المحتوى في الصفحة رقم 10
INSTALLATION Install Console Hold the Console with the front toward you Pull the two Console inner members of the and as horizontal as possible. NOTE: In slides out until they lock in the second lock the next step, be sure to carefully support position. and guide the power supply at the rear of the Console. Press in the first set of catches on each Guide the Console’s inner slide member slide and slide the channel until the second into the middle slide member, and gently safety catches
ملخص المحتوى في الصفحة رقم 11
INSTALLATION Secure the power supply to the right rear of Secure the left side also, as shown above. the Console, using #8-32 x .75”L screws. 11 Doc# 27-0032UM Rev A Issued 07/05
ملخص المحتوى في الصفحة رقم 12
INSTALLATION Z Locks Description The mechanical principle of the Z Locks is similar to spring-loaded dead bolts. Two stainless steel compression springs in each lock press against the bolt so that it will not come loose even with substantial force. Push Tab Slide cover Spring loaded catch Slide body Left and right units are identical 12 Doc# 27-0032UM Rev A Issued 07/05
ملخص المحتوى في الصفحة رقم 13
INSTALLATION Setup Console To pull out the Command Console, place Your thumb should be on the tab of the your hands so that your palms face up- lock and the first three fingers are under wards. the pull-out bar. Push the tabs towards each other and with Press both slide catches inward and pull your fingers pull out the Console until the the Console out. Allow the Console to stop first safety catch stops the slide action. at the second catch. To raise the display into viewing position, right
ملخص المحتوى في الصفحة رقم 14
INSTALLATION ...into viewing position. Push unit into the first locking position of the slides. 14 Doc# 27-0032UM Rev A Issued 07/05
ملخص المحتوى في الصفحة رقم 15
INSTALLATION Close Console To fold down the Console, pull out the Stand slightly to the right of the unit and Console fully from the rack lower the panel down on its back into the tray. With the right hand pull back on the tab of Lay the panel fully down and release so the lock down mechanism. that the panel becomes locked in the hori- zontal position. Disengage the slide lock from the second With a Thumb on the left and right tab of slide lock position. Push the Console into the Z Lock, sl
ملخص المحتوى في الصفحة رقم 16
OPERATIONS CABLE CONNECTIONS The connections panel may vary due to non-standard configurations. The following con- figuration shows both PS2 and USB cable connections on one sample. In most cases, the Command Console will utilize just one of these connector types. PS2 KEYBOARD TRACKBALL VIDEO POWER USB (TYPE B) HOST SERIAL KEYBOARD , TRACKBALL POWER UP When the Command Console is connected, apply power and ensure the main screen appears. If the display does not turn on within ten seconds, pre
ملخص المحتوى في الصفحة رقم 17
> < OPERATIONS DISPLAY PANEL CONTROLS The Command Console features push-button controls on the lower front of the front bezel. To setup the display, use the following controls to fine tune the image on the screen: NOTE: The following procedures are written for setup using the buttons on the display panel. See the “SoftMenus” section of this manual for remote setup. Button functionality description table: Auto Main Adjust < > Menu Exit Display “Z” Key Auto Move up Move Move Move Acti- Ex
ملخص المحتوى في الصفحة رقم 18
OPERATIONS DISPLAY PANEL SETUP This following section explains how to use the control buttons to adjust image clarity and image position on the screen. In particular it discusses: • The function of each of the push-button controls • How to reset previously saved settings or return to factory settings • Tips and techniques NOTE: The control buttons allow the user to control backlight operations; to store settings, and to revert to factory-saved settings. 18 Doc# 27-0032UM Rev A Issued
ملخص المحتوى في الصفحة رقم 19
OPERATIONS ONSCREEN MENUS To access the onscreen display main menu, press the menu button on the front of the panel. The Command Console’s functions are controlled using the Main Menu’s subtopics. These submenus can be accessed using the Up and Down buttons on the display panel. See sections below for specifics regard- ing the submenus. Main Screen Picture Adjust Use the Up and Down buttons to highlight the “Picture Adjust” option. Press the “Menu” button to access the submenu. Use the
ملخص المحتوى في الصفحة رقم 20
OPERATIONS Main Screen Graphics Mode Use the Up and Down buttons to highlight the “Graphics Mode” option. Press the “Menu” button to access the “Graphics Mode” submenu. “Graphics Mode” is used to adjust the positioning of the image. Use the Up and Down Keys to highlight the desired option. Use the Left and Right buttons to adjust the following modes: Horz Coarse, Horz Fine, H Pos, and V Pos. The “Horz Coarse” option adjusts the horizontal width of the image. The “Horz Fine” option