ملخص المحتوى في الصفحة رقم 1
Wall Mounted Mini Split
Heat Pump
Air Conditioner
OPERATING AND INSTALLATION MANUAL
Model: KFHHP-22-ID / KFHHP-22-OD
Indoor Unit.
Outdoor Unit.
Thank you for selecting Soleus Air. To ensure proper
operation, please read this manual and keep it for
future reference.
ملخص المحتوى في الصفحة رقم 2
TABLE OF CONTENTS OPERATION AND MAINTENANCE…………..………..…………………………………….....1-12 Instructions before Use ……………………………………………………………………………1-2 Description of Air Conditioner Components………………………………………………...………3 Remote Control Operation…………………………………………………………………………4-6 How to Insert Batteries…………………………………………………….…………………………6 User Notices…………………………………………………….………………….…………………7 Care and Maintenance………………………………………………….......……………...….……8-9 Trouble-Shooting…………………………………………………….…...……..…………..……
ملخص المحتوى في الصفحة رقم 3
Operation and Maintenance ◆ Instructions before Use Carefully read the following instructions before use Warning ★Do not use flammable liquids on or near this air ★Touching metal parts after removing filter can conditioner. cause an electric shock. ★Do not use for long periods of time if the ★Don’t operate the air conditioner with web humidity is high. Condensation may be present. hands. It can cause an electric shock. ★Do not insert your
ملخص المحتوى في الصفحة رقم 4
◆Instructions before Use ★Don’t attempt to repair the air conditioner by ★Always use new batteries in your remote. Never mix batteries. yourself. There are no user replaceable parts. Please contact your authorized dealer. ★Be sure to turn the power off when not using the ★Never store flammable liquids near your air air conditioner for a long time. conditioner. ★The condensing unit should be ★Don’t step on the top of the
ملخص المحتوى في الصفحة رقم 5
◆Description of Air Conditioner Components Air intake On/Off Switch Air outlet On/Off Switch Signal Sensor Connecting Pipe / Line set - 3 -
ملخص المحتوى في الصفحة رقم 6
◆Remote Control Operation Function-Remote control Note: • Don't drop the remote control. • Don't place the remote control in a location exposed to direct sunlight. • When the unit is restarted after stopped, it will automatically resume its last running mode, and the outdoor unit will start there after. MODE Button: TEMP+ TEMP- Button: When the unit is turned on, press this Under the COOL, DRY, button. The AUTO, FAN or HEAT mode, press COOL, D
ملخص المحتوى في الصفحة رقم 7
◆Remote Control Operation (Continued) Liquid Crystal Display. It shows all set contents. SWING Button: ON/OFF Button Press once to have louvers Press ON. swing [oscillate]. Press Press OFF. twice in one second the panel light will turn on. Press twice again and the light will turn off. T-ON Button. When pressing this button once, enter into T-ON setting, the icon of T-ON flash, every press of T-OFF Button TIME+, the time of T-ON will
ملخص المحتوى في الصفحة رقم 8
◆Remote Control Operation (Continued) The General Procedure: 1. Press ON/OFF button to start the unit. 2. Press MODE button to select the suitable operation mode. 3. Press SWING button to swing. It will stop when pressed again. 4. Press FAN button to set desired fan speed. 5. Press +/- button to set desired temperature. The Selected Procedure: 6. Press SLEEP button to set timer. 7. Press ON/OFF button to set desired temperature. Note: In AUTO mode, the un
ملخص المحتوى في الصفحة رقم 9
◆User Notices ★Select the most comfortable temperature. ★The airflow direction can be adjusted. At operating, adjust the vertical airflow direction by adjusting the louvers of upward/downward direction. And then, hold two ends of left and right louver to adjust the horizontal airflow. ★Don’t leave windows and doors open for a long ★Splashing water on the air conditioner can time while operating the air conditioner. cause an electric shock and malfu
ملخص المحتوى في الصفحة رقم 10
◆Care and Maintenance CAUTION: Turn power off and pull out the power cord before cleaning air conditioner. Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock. Volatile Liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a dry soft cloth, or a cloth slightly moistened with water or cleanser.) Take down the surface panel and clean it (Take it down before cle
ملخص المحتوى في الصفحة رقم 11
◆Care and Maintenance (Continued) 3. Reinsert the filters Reinsert the filters along the direction of arrow, then cover the surface panel and clasp it. Check before Use 1. Be sure that nothing obstructs the air outlet and intake vents. 2. Verify that the unit is properly grounded. 3. Always use new batteries. 4. Verify condenser is properly mounted. Maintain after Use 1. Clean filters and other parts. 2. Turn main power off. 3. Clean dust from the ou
ملخص المحتوى في الصفحة رقم 12
◆Trouble Shooting Problem Trouble Shooting Sound of water flow can be heard during operation. This is caused by the refrigerant flowing inside the unit. Mist is emitted during cooling operation. Because the air of the room is cooled down rapidly. Creaking noise can be heard when start or stop the unit. This is caused by the expansion of plastic due to the change of temperature. Air conditioner does not operate at all. • Has the power been shut down? • Is
ملخص المحتوى في الصفحة رقم 13
◆Specifications and Technical Data Model KFHHP-22-ID / KFHHP-22-OD Function Heating and Cooling Cooling capacity(BTU/hr) & (Watts) 22000 / 6450 (2250-7000) Heating capacity(BTU/hr) & (Watts) 24200 / 7100 (1650-8500) Rated voltage 208-230V~ Rated Frequency 60Hz Cooling/Heating rated current(A) 10.0/9.3 Cooling/Heating rated power(W) 3300/3200 Cooling/Heating power input(W) 2280/2250 SEER 14 EER/COP(W/W) HSPF 8.4 3 Recycling Air Volume(m /h) 1100/1000/900 Fact
ملخص المحتوى في الصفحة رقم 14
Installation Services ◆Installation Diagram Important Notes The installation must be done by trained and qualified service personnel. - 12 -
ملخص المحتوى في الصفحة رقم 15
◆Installation Location Indoor Unit 1. The inlet and outlet should not be covered so that the outflow air can reach all parts of the room. 2. Install in a location from which the condensation water can be drained out conveniently. 3. Avoid a location where there is heat source, steam or flammable gas. 4. Install in a location where is strong enough to withstand the full weight and vibration of the unit. 5. Be sure that the installation conforms to the installation d
ملخص المحتوى في الصفحة رقم 16
◆Installation Install the rear panel 1. Always mount the rear panel horizontally. Because the mouth of drainage pipe is at the left side and the left side of the rear panel is better to adjust slightly lower. 2. Fix the rear panel on the selected location with screws supplied with the unit. 3. Be sure that the rear panel has been fixed firmly enough to withstand the weight of an adult of 132.3 lbs; furthermore, the weight should be evenly shared by each scre
ملخص المحتوى في الصفحة رقم 17
◆Installation Wiring of indoor unit Note: The power of indoor unit is supplied by the outdoor. A breaker needs to be installed for safety. Operation Procedures: 1. Open the surface panel. 2. Open the cover and cover plate of electric box. (Right figure) 3. Remove the receiving window as shown in the below left figure. 4. Wire pipe should be tightened by the fixed nut and the electric box should be fixed as shown in the above right figure a
ملخص المحتوى في الصفحة رقم 18
◆Installation Electric Wiring Note: Wiring must be done by a certified technician according to the local rules & regulations. The connecting wire should be correctly connected to circuit interface. Otherwise, it can cause a fire, electricity leakage and so on. The diagram is shown as below: NOTE: 1. Wiring should be correctly installed. 2. Tighten the nut of terminal board to avoid falling off. 3. Incorrect wiring will cause the unit to malfunction
ملخص المحتوى في الصفحة رقم 19
◆Installation Wiring of Outdoor unit Operation Procedures: • Open the cover of outdoor unit. • The connecting wire led from the terminal board of indoor unit should be connected correctly. • The connecting wire should be a little longer so that it can easily maintained. NOTE: 1. Wiring should be correctly installed. 2. Tighten the nut of terminal board to avoid falling off. 3. Incorrect wiring will cause the unit to malfunction. 4. Units that are
ملخص المحتوى في الصفحة رقم 20
◆Installation Install the Power Line 1. Remove the front side plate. 2. Break through the hole for wires and put on the rubber bushing. 3. Pull all wires through the rubber bushing. 4. Remove the wire clamp and connect the end of the power connection cord with screws to the wiring terminal board according to the “WIRING DIAGRAM” of the outdoor unit. 5. Make sure that the wiring has been connected properly. 6. Tighten the wire with clamp and clasp. 7. After the